NOTE:
It is recommended that you always use an antistatic mat and antistatic strap while working on components inside
the system.
NOTE:
While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same
firmware and configuration of the replaced one. For more information about the Part replacement configuration, see the
Lifecycle Controller User's Guide at
NOTE:
While replacing faulty storage controller/FC/NIC card with the same type of card, after you power on the system;
the new card automatically updates to the same firmware and configuration of the faulty one. For more information about
the Part replacement configuration, see the Lifecycle Controller User's Guide at
NOTE:
For detailed information on cabling the PERC 11 cards, see the system-specific owner's manual at Installation and
Service Manual available at
Before working inside your system
Prerequisites
Follow the safety guidelines listed in
Steps
1. Power off the system and all attached peripherals.
2. Disconnect the system from the electrical outlet, and disconnect the peripherals.
3. If applicable, remove the system from the rack.
For more information, see the Rail Installation Guide relevant to your rail solutions at www.dell.com/poweredgemanuals.
4. Remove the system cover.
After working inside your system
Prerequisites
Follow the safety guidelines listed in
Steps
1. Replace the system cover.
2. If applicable, install the system into the rack.
For more information, see the Rail Installation Guide relevant to your rail solutions at www.dell.com/poweredgemanuals.
3. Reconnect the peripherals and connect the system to the electrical outlet, and then power on the system.
Recommended tools
You need the following tools to perform the removal and installation procedures:
● Key to the bezel lock. The key is required only if your system includes a bezel.
● Phillips #1 screwdriver
● Phillips #2 screwdriver
● Torx #T20 screwdriver
● 5mm hex nut screwdriver
● Plastic scribe
● 1/4 inch flat blade screwdriver
● Wrist grounding strap connected to the ground
● ESD mat
You need the following tools to assemble the cables for a DC power supply unit:
● AMP 90871-1 hand-crimping tool or equivalent
https://www.dell.com/idracmanuals
https://www.dell.com/poweredgemanuals
Safety
instructions.
Safety
instructions.
https://www.dell.com/idracmanuals
Installing and removing system components
27