6. OPERATION
6-4. Cycle program
Cycle programs can consist of up to a maximum of four independent programs (A to D).
A single cycle program can contain up to a maximum of eight steps.
The following shows an example of storing a cycle program into cycle program A that consists of four steps of
program 1 with knife operation on, and one step of program 3 with knife operation off.
Step 1
Program No.
Knife operation
43
Step 2
1
1
ON
ON
Step 3
Step 4
1
1
ON
ON
3052Q
1. Press the SELECT key (1) to change the mode to
automatic, manual or test feed mode.
2. Press the
"A".
Note: Cycle program mode is not available if an
independent program has been selected.
3. Press the SELECT key (1). The cycle program
mode indicator (2) will illuminate.
* The cycle program number "A" and the step
number "1" will appear in the program number
display (3), and the cycle program details will
appear in the detail display (4).
4. Press the
step 1 to "1.", and then press the ENTER key (5) to
accept the "1." setting.
* "." signifies that knife operation is on.
* "-" signifies a clear status. If "-" is set, the setting
details for all subsequent steps will be cleared.
5. Press the
number to "2", and then repeat step 4 above.
6. Press the
number to "3", and then repeat step 4 above.
7. Press the
number to "4", and then repeat step 4 above.
8. Press the
number to "5".
9. Press the
2410Q
step "5" to "3.".
10. Press the OFF key (6) so that the "." disappears,
and then press the ENTER key (5) to accept the
"3" setting.
11. Press the SELECT key (1). Cycle program mode
will end and the mode will change to automatic
mode.
2411Q
RH-981A
Step 5
3
OFF
and
keys to select cycle program
and
keys to change the setting for
and
keys to change the step
and
keys to change the step
and
keys to change the step
and
keys to change the step
and
keys to change the setting for