Control Commands for NEC Projector (Basic) Rev 11.03.11a
Copyright (C) NEC Display Solutions, Ltd. 2002-2011
----------------------------------------------------------------------
Updated on November 03, 2011
----------------------------------------------------------------------
This file contains information about NEC projector control commands.
Model Name
GT60
: GT5000/GT6000 Series
GT50
: GT1150/GT2150 Series
HT
: HT1000/HT1100 Series
HT10
: HT410/HT510 Series
LT180
LT180
LT30
: LT25/LT30/LT35 Series
LT
:
LT220/LT240/LT240K/LT260/LT260K/LT245/LT265 Series
LT80
: LT280/LT380 Series
MT70
: MT860/MT1060/MT1065/MT1075 Series
NP60
: NP40/NP50/NP60 Series
NP62
: NP41/NP61/NP62 Series
NP1000 : NP1000/NP2000 Series
NP3150 : NP1150/NP2150/NP3150/NP3151W Series
NP4000 : NP4000/NP4001 Series
NP905
: NP905/NP901W/VT800 Series
NP600
: NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S Series
VT
:
VT770 Series
VT70
:
VT37/VT47/VT480/VT57/VT570/VT575/VT670/VT676 Series
VT80
:
VT48/VT480/VT580 Series
VT90
:
VT49/VT490/VT590/VT595/VT695 Series
VT700
:
VT700
WT
: WT600/WT610/WT615 Series
NP4100 : NP4100/NP4100W Series
NP3250 : NP1250/NP2250/NP3250/NP3250W Series
NP610
: NP310/NP410/NP410W/NP510/NP510W/NP510WS/NP610/NP610S Series
NP2200 : NP1200/NP2200 Series
NP216
: NP110/NP115/NP215/NP216 Series
NP64
: NP43/NP64 Series
M300
: M260X/M260W/M300X/M300W Series
P420
:
P350X/P350W/P420X Series
U300
:
U300X/U310W Series
V300
:
V260/V260X/V300X/V300W Series
PA600
: PA600X/PA550W/PA500U/PA500X
PX750U
PX750U Series

Advertisement

loading

Summary of Contents for NEC NP-PX700W

  • Page 1 Control Commands for NEC Projector (Basic) Rev 11.03.11a Copyright (C) NEC Display Solutions, Ltd. 2002-2011 ---------------------------------------------------------------------- Updated on November 03, 2011 ---------------------------------------------------------------------- This file contains information about NEC projector control commands. Model Name GT60 : GT5000/GT6000 Series GT50 : GT1150/GT2150 Series...
  • Page 2 5. Command Descriptions 6. Table of Response Error Codes ====================================================================== 1. Projector Control ---------------------------------------------------------------------- NEC projectors make use of control commands that control the functions of the projector via connection with a personal computer or another device. ====================================================================== 2. Connection Method ---------------------------------------------------------------------- The following 3 kinds of connection methods are available for sending and receiving control commands.
  • Page 3 [P350X/P350W/P420X Series] STANDBY MODE: "POWER-SAVING" Serial Wired Wireless Control Command port LAN port LAN unit POWER ON Yes: Supported No: Not supported ==================================================================== 3. Interface Conditions ---------------------------------------------------------------------- Serial connection ---------------------------------------------------------------------- The communications method conforms to the RS-232C standard.
  • Page 4 (3-1) (3-2) (3-3) (3-4) Wired Wireless Wired Wireless Serial Port USB Port LAN Card LAN Card LAN Port LAN Port GT5000/GT6000 GT1150/GT2150 HT410/HT510 HT1000/HT1100 LT180 LT25/LT30/LT35 LT220/LT240/LT260 LT240K/LT260K LT245/LT265/LT280/LT380 MT860/MT1060/MT1065/MT1075 NP40/NP50/NP60 NP41/NP61/NP62 NP43/NP64 NP1000/NP2000 NP1150/NP2150/NP3150/NP3151W NP4000/NP4001 NP905/NP901W NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S VT770 VT37/VT47/VT470/VT57/VT570/VT575VT/670/VT676 VT48/VT480/VT580 VT49/VT490/VT590/VT595/VT695/VT700 VT700...
  • Page 5 ( CAUTION ) Before making connections, set the standby mode of the projector to "NORMAL" or "Idol mode". The projector cannot use the control commands in the power-saving condition, but the following model can use some control commands. [P350X/P350W/P420X Series] STANDBY MODE: "POWER-SAVING"...
  • Page 6 [ GT/LT80/MT/NP1000/VT (except VT70/VT80/VT90)/NP3150/NP905/NP600/NP4000/NP3250/NP610/NP2200/NP216/M300/P420/U300/V300 ] The PC CONTROL connector is a D-SUB 9-pin connector. 2 To TxD of PC 3 To RxD of PC 5 To GND of PC 7 To CTS of PC 8 To RTS of PC ==================================================================== 4.
  • Page 7 This is an identification data assigned to each command. Command : This sets an identification data assigned to each command to send it. ( See each command description.) Response : This returns the 6th bit of received ID1 as HIGH. For ACK it sends the 8th bit back as LOW (recognized);...
  • Page 8 * When the controller is connected with the projector on a one-to-one basis Broadcast notification is recommended. * When the controller is connected with multiple projectors To control a certain projector, use "individual notification". For all others "broadcast notification" is recommended. Response : This returns the model code for a projector received regardless of individual notification or broadcast notification.
  • Page 9 4-2. Data portion of response ********************************************************************** For ACK This returns ACK without adding data portion to the command that does not request data. This returns ACK with adding data to the data portion for the command that requests data. For NAK This adds a cause of not accepting the command to data portion to return it.
  • Page 10 Not used [ Wired/wireless LAN card ] The LAN connections will differ depending on the commercial LAN card that is used. - For information on supported LAN cards, visit: Global: http://www.nec-pj.com/ [Port Number] The TCP port number used is "7142".
  • Page 11 ==================================================================== 4. List of Commands ---------------------------------------------------------------------- * Example for command ---------------------------------------------------------------------- Command name Example ---------------------------------------------------------------------- 006. RUNNING SENSE 00H 81H 00H 00H 00H 81H 007. COMMON DATA REQUEST 00H C0H 00H 00H 00H C0H 009. ERROR STATUS REQUEST 00H 88H 00H 00H 00H 88H 015.
  • Page 12 05 : MT860 06 : WT600/WT610/WT615 07 : GT5000 08 : LT240K/LT260K 09 : GT6000 10 : HT1100 11 : VT770 12: HT410/HT510 (HT10 Series) 13 : LT245/LT265 14 : LT280/LT380 15 : LT180 16 : VT37/VT47/VT470/VT57/VT570/VT575/VT670/VT676 (VT70 series) 17 : VT48/VT480/VT580 (VT80 Series) 18 : NP1000/NP2000 (NP1000 Series) 19 : NP1150/NP2150/NP3150/NP3151W (3150 Series) 20 : LT25/LT30/LT35 (LT30 Series)
  • Page 13 Meaning of Symbols -------------------------------------------------------------------- * Supported ! Is available depending on model's version - Not Supported Availability by Model (CURRENT MODELS) Command Name 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 006. RUNNING SENSE 007.
  • Page 14 Availability by Model (LEGACY MODELS) Command Name 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 28 006. RUNNING SENSE 007. COMMON DATA REQUEST 009. ERROR STATUS REQUEST 015. POWER ON 016. POWER OFF 018.
  • Page 15 In case of NP216 series In case of V300 series In case of VT series In case of NP600 series In case of NP610 series In case of NP2200 series In case of M300 series In case of P420 series In case of GT series In case of HT series In case of WT series...
  • Page 16 DATA01 Status of operation Bit 7: Power On/Off processing 0 = No execution (Normal condition) 1 = During execution Bit 6: Selecting signal processing 0 = No execution (Normal condition) 1 = During execution Bit 5: Cooling processing 0 = No execution (Normal condition) 1 = During execution Bit 4: External control mode 0 = OFF...
  • Page 17 00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06 Indication signal number (Entry list number - 1) 0 .. 199 DATA07 Type 1 of input terminal to be selected (!) 01H : 1 02H : 2 03H : 3 04H : 4...
  • Page 18 DATA32 Freeze Status (!2) 00H : OFF 01H : ON FFH : Not Supported DATA33 Test pattern display 1 00H : No display (Normal condition) 00H Other : Displaying (Pattern ID) Pattern ID Pattern Name MT LT LT180 LT80 HT GT W T VT NP1000 NP3150 NP905 NP4000 NP4100 NP62 NP64 NP3250 NP216 P420 V300...
  • Page 19 DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 ..
  • Page 20 Data01 Data70 Data71 MT1060/MT1065 MT860 MT1075 NP1000/NP2000 LT240/LT260 LT220 LT240K/LT260K LT245/LT265 LT380 LT280 VT770 VT80 Series VT90 Series GT1150 GT2150 GT5000 GT6000 HT1000 HT1100 WT600 WT610/WT615 NP4000/NP4001 NP4100 NP4100W VT700 NP600 NP500 NP500 W NP400 NP300 NP610 NP510 NP510W NP410 NP310 NP610S NP510WS...
  • Page 21 DATA72 PC Card insertion 00H : Not inserted 01H : Inserted DATA73 USB Mouse connection 00H : Not connected 01H : Connected DATA74 Entry list type 01H : Default 02H : User DATA75 .. 82 Reserved DATA83 On-screen mute 00H : OFF 01H : ON DATA84 Reserved...
  • Page 22 009. ERROR STATUS REQUEST ********************************************************************** Function: This command acquires the error information occurring with the projector. Command: 00H 88H 00H 00H 00H 88H Response: At the time of a success 20H 88H 01H xxH 0CH DATA01 .. DATA12 CKS (*1) (*2) (*3) Data Portion Contents -------------------------------------------------------------------...
  • Page 23 Supplement: (!) LT/LT80/HT: "None" 015. POWER ON ********************************************************************** Function: This command switches on the main power of the projector. Command: 02H 00H 00H 00H 00H 02H Response: At the time of a success 22H 00H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure...
  • Page 24 DATA02 Switching number --------------------------------------------------------- When the switching object is the "Signal list", the signal list number is specified. (0…99) --------------------------------------------------------- When the switching object is the "Input connector", the input connector number is specified. Terminal Terminal CURRENT MODELS Number Name NP4000/4100 NP905 NP600 NP62/64 NP3250 NP610 NP2200 NP215 NP216 M300 P420 U300 V300 PA600 PX750 RGB1(RGB)
  • Page 25 Response: At the time of a success 22H 03H 01H xxH 01H DATA01 CKS (*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------- DATA01 Results 00H : Normal FFH : Error Response: At the time of a failure A2H 03H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3)
  • Page 26 022. SOUND MUTE ON ********************************************************************** Function: This command mutes the sound. Command: 02H 12H 00H 00H 00H 14H Response: At the time of a success 22H 12H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 12H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4)
  • Page 27 025. ONSCREEN MUTE OFF ********************************************************************** Function: This command cancels the blanking of the on-screen display. Command: 02H 15H 00H 00H 00H 17H Response: At the time of a success 22H 15H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 15H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4)
  • Page 28 DATA03 : 00H (direct settings) 01H (increment/decrement) DATA04 : lower data (8bit) DATA05 : upper data (8bit) ex.1) volume direct setting (value = 20) DATA01 : 05H (Volume) DATA02 : 00H ("Volume" only) DATA03 : 00H (direct setting) DATA04 : 14H (lower data : 20 = 0014<Hex>) DATA05 : 00H (upper data : 20 = 0014<Hex>) ex.2) brightness increment (value = +1) DATA01 : 00H (Brightness)
  • Page 29 ------------------------------------------------------------------- DATA01 .. 02 Results 0000H : Normal 0000H Other : Error Response: At the time of a failure A3H 10H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * Setting Volume to "10" 03H 10H 00H 00H 05H 05H 00H 00H 0AH 00H 27H 030-12.
  • Page 30 DATA04 DATA05 Aspect Ratio 4:3 (Window) Aspect Ratio Normal / Auto (NP600, NP610, NP2200, NP62, NP64, NP216, P420, PA600, U300, V300 Series) Aspect Ratio 1.25:1(5:4) Aspect Ratio Letter Box (PA600, PX750 Series) Aspect Ratio 1.33:1(4:3) Aspect Ratio Wide Zoom (NP600, NP610, NP2200, NP62, NP64, NP216, P420, V300 Series) Aspect Ratio Wide Screen (PA600, PX750 Series) Aspect Ratio 1.78:1(16:9) Aspect Ratio Cinema / 16:9 (NP600, NP610, NP2200, NP62, NP64, NP215, P420, PA600, U300, V300 Series)
  • Page 31 Supplement: (!) Lamp Hour Meter This is the timer for normal lamp mode conversion. Lamp Timer Acquisition Examples DATA83 DATA84 DATA85 DATA86 : Lamp Timer 00H : Total 0 seconds 00H : Total 5400000 seconds/3600 = 1500 hours 00H : Total 5760000 seconds/3600 = 1600 hours Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA86 DATA85 DATA84 DATA83 (005265C0)
  • Page 32 2) Punch in DATA12 DATA11 DATA10 DATA09 (006DDD00) 3) Change from HEX to Decimal - value will change to 7200000 seconds Lamp remaining time (in terms of Normal mode values) = (7200000 - 10800) / 3600 = 1997 hour 037-2. LAMP INFORMATION REQUEST 2 ********************************************************************** Function: This command acquires lamp remaining amount.
  • Page 33 to appear (in terms of Eco mode values) 10H : Remaining time until inhibition of lamp usage (in terms of specified values) 11H : Remaining time until inhibition of lamp usage (in terms of Normal mode values) 12H : Remaining time until inhibition of lamp usage (in terms of Eco mode values) Response: At the time of a success 23H 96H 01H xxH 06H DATA01 ..
  • Page 34 Function: This command acquires the information on the projector lamp. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS (*3) Data Portion Contents ----------------------------------------------------------------- DATA01 Target 00H : Lamp1 01H : Lamp2 DATA02 Unit(!4) 00H : Second 01H : Reserved 02H : Hour DATA03 Item...
  • Page 35 Lamp Use Warning Starting Time 2000[H] Model. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp Hour Meter This is the timer for normal lamp mode conversion. (!3) Lamp usage time This is the lamp total usage. It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time.
  • Page 36 00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 046. WXGA MODE SETTING REQUEST ********************************************************************** Function: This command acquires the setting of the WXGA Mode of projector. Command: 03H B0H 00H 00H 01H C3H 77H Response: At the time of a success...
  • Page 37 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) ====================================================================== 6. Response ---------------------------------------------------------------------- * At the time of a success( ACK ) This returns ACK without adding data portion to the command that does not request data.
  • Page 38 Key number DATA01 DATA02 Key name -------------------------------------------- POWER POWER ON (!!) POWER OFF (!!) SOURCE (AUTO) (!!) AUTO (!) (!!) MENU (!!) (!!!) UP (!!) (!!!) DOWN (!!) (!!!) RIGHT (!!) (!!!) LEFT (!!) (!!!) ENTER (!!) (!!!) CANCEL (!!) (!!!) HELP (!!) (!!!) POINTER MAGNIFY UP...
  • Page 39 S-VIDEO1 (!!) S-VIDEO2 DIGITAL1 DIGITAL2 PC CARD VOLUME UP (!!) VOLUME DOWN (!!) KEYSTONE UP (!!) KEYSTONE DOWN (!!) SLIDE UP SLIDE DOWN FREEZE (!!) FILE PAGE ASPECT (!!) VIDEO3 VIDEO4 S-VIDEO3 S-VIDEO4 ZOOM FOCUS 3D REFORM SOURCE (!!) RGB(*5) oggle (!!) VIDEO Toggle (!!) 3D REFORM RESET AUTO (SHORT)
  • Page 40 Command example: * Sending the AUTO key code 02H 0FH 00H 00H 02H 05H 00H 18H * Sending the AUTO (SHORT) key code 02H 0FH 00H 00H 02H DDH 00H F0H ------------------------------------------ * cycle/toggle volume mute * cycle/toggle picture mute * cycle/toggle picture freeze 02H 0FH 00H 00H 02H DATA01 DATA02 CKS Data Portion Contents...
  • Page 41 051. CARBON SAVINGS INFORMATION REQUEST ********************************************************************** Function: This command acquires the Carbon Saving values on the projector. Command: 03H 9AH 00H 00H 01H DATA01 CKS (*3) Data Portion Contents ------------------------------------------------------------------- DATA01 Acquirement items 00H : Total Carbon Savings 01H : Carbon Savings during operation Response: At the time of a success 23H 9AH 01H xxH 09H DATA01 to DATA09 CKS (*1) (*2)
  • Page 42 ------------------------------------------------------------------- DATA01 Target 00H : Use Point on Signal Change 01H : Picture mute during lens shift DATA02 Setting Value 00H : Inactive 01H : Active Response: At the time of a success 22H 21H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents...
  • Page 43 DATA09 Current value (Upper ranking 8 bits) DATA10 .. 13 Reserved Response: At the time of a failure A3H 04H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) (! ) Acquirement items Black Correct / Inv Gain Lamp Output DATA01 DATA02 Acquirement name Signal Level / Auto Control...
  • Page 44 Color Correction / Yellow Color Cor. Dual / Green Color Cor. Dual / Blue Color Correction / Magenta Color Correction / Cyan Color Cor. Dual / Yellow Color Correction / White Color Cor. Dual / Magenta Through Color Cor. Dual / Cyan Color Cor.
  • Page 45 077. MUTE CONTROL ********************************************************************** Function: This command controls the mute of picture, sound and on-screen. Command: 02H 1AH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents ------------------------------------------------------------------- DATA01 Setting items 00H : Picture 01H : Sound 02H : On-Screen DATA02 Setting Value 00H : OFF...
  • Page 46 DATA01 DATA02 DATA03 Current Models NP4100 NP4100W NP64 NP43 M300X M300W M260X M260W P420X P350X P350W U300X U310W PA600X PA500X PA550W PA500U V300X V260X V260 PX750...
  • Page 47 Legacy Models MT1060/MT1065 MT860 MT1075 NP1000/NP2000 LT240/LT260 LT220 LT240K/LT260K LT245/LT265 LT380 LT280 VT80 Series VT90 Series GT1150 GT2150 GT5000 GT6000 HT1000 WT600 WT610/WT615 NP4000/NP4001 NP4100 NP4100W VT700 NP600 NP500 NP500 W NP400 NP300 NP610 NP510 NP510W NP410 NP310 NP610S NP510WS NP410 NP2200 NP1200...
  • Page 48 DATA05 Calendar function 00H : No function 01H or 03H : Timer function, sleep timer function 02H : Sleep timer function DATA06 .. 32 Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4)
  • Page 49 (*1) (*2) (*4) (*3) 078-3. INPUT STATUS REQUEST ********************************************************************** Function: This command acquires the status of input signal of the projector. Command: 00H 85H 00H 00H 01H 02H 88H Response: At the time of a success 20H 85H 01H xxH 10H DATA01 .. DATA16 CKS (*1) (*2) (*3) Data Portion Contents...
  • Page 50 01H : Displaying DATA07 ..08 Reserved DATA09 Indicate Contents 00H = Picture signal displaying 01H = No signal 02H = Viewer displaying 03H = Test pattern displaying 04H = LAN displaying DATA10 .. 16 Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2)
  • Page 51 078-5. MODEL NAME REQUEST ********************************************************************** Function: This command acquires the model name of the projector. Command: 00H 85H 00H 00H 01H 04H 8AH Response: At the time of a success 20H 85H 01H xxH 20H DATA01 .. DATA32 CKS (*1) (*2) (*3) Data Portion Contents -------------------------------------------------------------------...
  • Page 52 Function: This command controls the freeze. Command: 01H 98H 00H 00H 01H DATA01 CKS Operation types DATA01: 00H : Reserved 01H : Freeze start 02H : Freeze cancel Response: At the time of a success 21H 98H ID *0H 01H DATA01 CKS Data Portion Contents ------------------------------------------------------------------- DATA01...
  • Page 53 Data Portion Contents ------------------------------------------------------------------- DATA01 C5H fixed DATA02 Acquisition Object 00H : MODE 01H : POSITION 02H : SOURCE Response: At the time of a success 23H B0H 01H xxH 03H DATA01 DATA02 DATA03 CKS (*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------- DATA01 C5H fixed...
  • Page 54 if DATA02 is SOURCE(02H) 00H : OFF 01H : VIDEO 02H : S-VIDEO Response: At the time of a success 23H B1H 01H xxH 03H DATA01 DATA02 DATA03 CKS (*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------- DATA01 00H fixed DATA02 Update target ( Same as DATA02 of the transmit data ) DATA03...
  • Page 55 111. AUTO ADJUST EXECUTE2 ********************************************************************** Function: This command executes the Auto Adjust. Command: 03H BAH 00H 00H 01H 00H BEH Response: At the time of a success 23H BAH 01H xxH 01H 00H CKS (*1) (*2) (*3) Response: At the time of a failure A3H BAH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4)
  • Page 56 DATA02 DATA03 DATA13 DATA14 Current Models NP4100 NP4100W NP64 NP43 M300X M300W M260X M260W P420X P350X P350W U300X U310W PA600X PA500X PA550W PA500U V300X V260X V260 PX750...
  • Page 57 Legacy Models MT1060/1065 MT860 MT1075 NP1000/NP2000 LT240/LT260 LT220 LT260K LT245/LT265 LT380 LT280 LT180 LT25/LT30/LT35 NP40/NP50/NP60 VT770 VT80 Series VT90 Series GT5000 GT6000 GT6000R HT1000 HT1100 HT410 HT510 WT600 WT610/WT615 NP4000/NP4001 VT700 NP600 NP500 NP500W NP400 NP300 NP610 NP510 NP510W NP410 NP310 NP610S NP510WS...
  • Page 58 DATA15 ... 16 Reserved Response: At the time of a failure A0H BFH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 305-3. PROJECTOR INFORMATION REQUEST ********************************************************************** Function: This command acquires basic operation states of projector. Command: 00H BFH 00H 00H 01H 02H C2H Response: At the time of a success 20H BFH 01H xxH 10H DATA01 ...
  • Page 59 0CH : DIGITAL2 0DH : SCART 10H : AUTO FFH : Not Source Input Other : Not Support DATA06 Indication signal type (Effective only when Select source input type 2 is 02H or 03H) x0H : NTSC3.58 x1H : NTSC4.43 x2H : PAL x3H : PAL60 x4H : SECAM...
  • Page 60 ====================================================================== 6.1. Response ---------------------------------------------------------------------- * At the time of a success (ACK) This returns ACK without adding data portion to the command that does not request data. This returns ACK with adding data to the data portion for the command that requests data. * At the time of a failure (NAK) This adds a cause of not accepting the command to data portion to return it.