free stats
Download Print this page

Advertisement

Quick Links

Operating and installation instructions
Cooker hoods
DA 3160
DA 3180
DA 3190
DA 3160 EXT
DA 3190 EXT
To avoid the risk of accidents
GiOZHr
or damage to this appliance
it is
to read these
instructions before it is installed
and used for the first time.
M.-Nr. 06 681 580

Advertisement

loading

Summary of Contents for Miele DA 3160 EXT

  • Page 1 Operating and installation instructions Cooker hoods DA 3160 DA 3180 DA 3190 DA 3160 EXT DA 3190 EXT To avoid the risk of accidents GiOZHr or damage to this appliance it is to read these instructions before it is installed and used for the first time.
  • Page 2 ......... . 3 .
  • Page 3 Electrical and electronic appliances often contain materials which, if The transport and protective packing handled or disposed of incorrectly, has been selected from materials which could be potentially hazardous to are environmentally friendly for human health and to the environment. disposal, and can normally be They are, however, essential for the recycled.
  • Page 4 This appliance complies with all Before connecting the appliance to relevant local and national safety the mains supply, make sure that requirements. Inappropriate use the voltage and frequency details given can, however, lead to personal injury on the data plate correspond with the and damage to property.
  • Page 5 When cooking with oil or fat, chip These models may only be combined pans and deep fat fryers etc, do with a Miele external motor. not leave the pans unattended. Never In countries where there are areas leave an open grill unattended when which may be subject to infestation grilling.
  • Page 6 The filter should be regularly cleaned or changed as The appliance is only intended for appropriate. A saturated filter is a fire use by adults who have read these hazard. See "Cleaning and care". instructions. Keep children well away Do not use a steam-cleaner to from the appliance at all times and clean this appliance.
  • Page 7 All ducting, pipework and fittings - 650 mm above gas hobs and cookers, must be of non-flammable material. - 650 mm above an open grill or deep These can be obtained from the Miele fat fryer. Spare Parts department or from builders’ merchants.
  • Page 8 Harmful gases such as carbon monoxide could be drawn out of the chimney or extraction ducting back into the room, with potentially fatal consequences. In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the extractor and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar...
  • Page 9 The Miele DSM 400 offers the possibility of combining other components with the cooker hood (see "Operation with a DSM 400 control module").
  • Page 11 ø 150 mm (extra accessory available to order for recirculation mode) The front of the deflector plate can be fitted with a lightshield to match your kitchen furniture. The DA 3160 and DA 3190 can be fitted with a DFB 61 or DFB 91 lightshield, available as an optional accessory.
  • Page 12 Charcoal filters are available to order socket in the motor unit. through your Dealer or the Miele Spare Parts Department. (See back cover for Having a non-return flap fitted in the contact details and "Technical Data" for ducting ensures that air, once ducted to model number).
  • Page 13 All the indicator lamps will go out. If the cooker hood has been connected to a window contact switch via the Miele DSM 400 control ^ Pull out the deflector plate. module, then the fan cannot be switched on if the window is shut.
  • Page 14 You can set the Intensive setting so that it only runs for 10 minutes before ^ Press the touch control to activate reverting automatically to level III. automatic switch-off. ^ To set this option, both the fan and The indicator lamps for fan power the hob lighting must be switched off levels I and IV will now light up and the deflector plate pushed in.
  • Page 15 (in countries where this is applicable). A microfibre “E-Cloth” is available from (This infomation does not apply to the the Miele UK Spare Parts Department, controls). which is suitable for cleaning surfaces such as stainless steel, glass, plastic Stainless steel surfaces can be cleaned...
  • Page 16 (optional accessory) Aluminium is affected by the way that light falls on it, by the surrounding environment and by the angle you observe it from. Aluminium surfaces may suffer discolouration or damage if soiling is ^ Grip the front of the deflector plate left on them for too long.
  • Page 17 Miele Spare Parts department. prevent the risk of these catching fire. See back cover for contact details, and "Technical data" for type and reference number.
  • Page 18 ^ Pull out the deflector plate, and remove the grease filter as described earlier. ^ Switch off the fan and the lighting. Exercise caution when changing halogen lamps. They get very hot during use, and remain hot for some time after being switched off. Do not touch the surface directly when changing a lamp, as grease particles from your fingers will...
  • Page 19 In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – Your Miele Dealer – The Miele Service Department (see back cover for address). When contacting your Dealer or the Service Department, please quote the model and serial number of your appliance.
  • Page 20 DA 3160 DA 3190* – The front section of the wall housing unit must be fitted with a shelf to the depth of the partition wall. – The partition wall in the wall unit must be removable. * Installation is also possible in a 600 mm wide unit.
  • Page 21 The minimum safety distances between the top of a cooker or hob and the bottom of the cooker hood are as follows, unless a greater distance is specified by the manufacturer of your cooking appliance: - 450 mm above electric hobs and cookers, - 650 mm above gas hobs and cookers,...
  • Page 23 for securing the vent ducting to the exhaust socket. for securing the cooker hood into the for exhaust ducting C125 mm (not on wall unit. EXT models). for fitting into the exhaust socket on the motor unit (only for air extraction mode, not on EXT models).
  • Page 25 = Depth of carcase minus depth of ^ Screw the spacer strip to the bottom appliance of the sides of the housing, flush with ^ The depth of appliance depends the rear wall. on the lightshield being used: – a Lightshield to match existing kitchen furniture –...
  • Page 26 ^ Place the appliance on its back. Do not remove the protective film between the deflector plate and the casing until the hood has been placed in the housing unit. ^ Screw the brackets onto the right and left inside walls of the housing unit as shown.
  • Page 27 Note for dismantling the cooker hood: Undoing the screws on the left and right inside the housing releases the brackets, allowing the appliance to ^ When fitting a DA 3180 or a DA 3190 be removed from the unit. into a 60 cm housing unit, unscrew the brackets on the deflector plate whilst it is pulled out.
  • Page 28 ^ Secure the front of the appliance to ^ Attach the lightshield (if using). the floor of the housing unit from below using 4 screws (6 screws for A DML 300 installation kit, available as 90 cm wide cooker hood). an optional accessory, is required for this.
  • Page 29 ^ Remove the protective strip around the edge of the grease filter. Replace the grease filter. ^ If the on-site ventilation system does ^ To do this, pull the deflector plate out. not have a , then the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit.
  • Page 30 For this, we recommend using the cable and the 6-pole plug connector. conversion kit available from your Miele dealer or the Miele Spare Parts Dept ^ Separate fitting instructions are (see "Technical data"). supplied with the external motor.
  • Page 31 – Where ducting is horizontal, it must Important: To avoid the danger of be laid to slope away at at least 1 cm toxic fumes please observe the per metre. Warning and Safety instructions. This is to ensure that condensate This is especially crucial when using cannot drain back into the cooker the cooker hood at the same time as...
  • Page 32 If the exhaust ducting is to run through To achieve even further reductions in rooms, ceiling space etc. where there noise levels, a special silencer can be may be great variations in temperature fitted in the ducting system. between the different areas, the It can be sited at any suitable position problem of condensation will need to in the ducting system between the...
  • Page 33 be provided for all poles. All electrical work should be For extra safety it is advisable to install undertaken by a suitably qualified a residual current device (RCD) with a and competent person in strict trip current of 30 mA. accordance with current national and local safety regulations (BS 7671 in the UK).
  • Page 34 The Miele DSM 400 control module can If the control module is be used to combine the cooker hood disconnected in order to operate the with other components. cooker hood without the window It enables the following: contact switch (e.g. after moving...
  • Page 35 The control module can be used to switch on the cooker hood lighting via a light switch in the house. The control module must be installed above the cooker hood housing. The control module is supplied with its own detailed operating and installation instructions.
  • Page 36 DA 3160 ....12 kg DA 3160 EXT ....10 kg DA 3190 .
  • Page 40 Alteration rights reserved / 1006 M.-Nr. 06 681 580 / 01 en - GB...

This manual is also suitable for:

Da 3160Da 3190 extDa 3180Da 3190