free stats
Motorola Symbol CS3000 Series Product Reference Manual

Motorola Symbol CS3000 Series Product Reference Manual

Hide thumbs Also See for Symbol CS3000 Series:
Table of Contents

Advertisement

Symbol CS3000 Series Scanner
Product Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Motorola Symbol CS3000 Series

  • Page 1 Symbol CS3000 Series Scanner Product Reference Guide...
  • Page 3 Symbol CS3000 Series Scanner Product Reference Guide 72E-136088-01 June 2010...
  • Page 4 The Motorola Software that may be included on this media, or included in the Motorola Product, is Copyright (c) by Motorola, Inc., and its use is subject to the licenses, terms and conditions of the agreement in force between the purchaser of the Motorola Product and Motorola, Inc.
  • Page 5: Revision History

    Revision History Changes to the original manual are listed below: Change Date Description -01 Rev A 06/2010 Initial release...
  • Page 6 Symbol CS3000 Series Scanner Product Reference Guide...
  • Page 7: Table Of Contents

    Table of Contents About This Guide Introduction ........................xi Chapter Descriptions ..................... xi Notational Conventions....................xii Related Documents ....................... xii Service Information......................xiii Chapter 1: Getting Started Introduction ........................1-1 Unpacking the Scanner ....................1-2 The Cradle ........................1-2 Connecting the Cradle .................... 1-2 Charging the Scanner Battery ..................
  • Page 8 Symbol CS3000 Series Scanner Product Reference Guide Beeper Indications ....................2-5 Chapter 3: User Preferences Introduction ........................3-1 Scanning Sequence Examples ..................3-1 Errors While Scanning ....................3-1 User Preferences Default Parameters ................3-2 Reset ..........................3-4 Reset Factory Defaults ....................3-4 Set Date and Time ......................
  • Page 9 Table of Contents Enable/Disable Bookland EAN ................4-7 Decode UPC/EAN Supplementals ................4-8 User-Programmable Supplementals ............... 4-12 Decode UPC/EAN Supplemental Redundancy ............4-12 Transmit UPC-A Check Digit .................. 4-13 Transmit UPC-E Check Digit .................. 4-13 Transmit UPC-E1 Check Digit ................4-14 UPC-A Preamble ....................
  • Page 10 Symbol CS3000 Series Scanner Product Reference Guide Enable/Disable Codabar ..................4-39 Set Lengths for Codabar ..................4-40 CLSI Editing ......................4-41 NOTIS Editing ......................4-41 MSI ..........................4-42 Enable/Disable MSI ....................4-42 Set Lengths for MSI ....................4-43 MSI Check Digits ....................4-44 Transmit MSI Check Digit ..................
  • Page 11: About This Guide

    About This Guide Introduction The Symbol CS3000 Series Scanner Product Reference Guide provides general instructions for setting up, operating, maintaining, and troubleshooting the scanner. The Symbol CS3000 series scanner is available in the following configurations: • CS3000 - USB (batch), 0.5 GB Flash •...
  • Page 12: Notational Conventions

    Related Documents • Symbol CS3000 Series Scanner Quick Reference Guide (p/n 72-136598-xx) provides general information to help the user get started with the scanner, including basic setup and operation instructions. For the latest version of this guide and all guides, go to: http://www.motorola.com/enterprisemobility/manuals.
  • Page 13: Service Information

    Software type and version number Motorola responds to calls by e-mail, telephone or fax within the time limits set forth in service agreements. If your problem cannot be solved by Motorola Enterprise Mobility Support, you may need to return your equipment for servicing and will be given specific directions.
  • Page 14 Symbol CS3000 Series Scanner Product Reference Guide...
  • Page 15: Chapter 1 Getting Started

    Chapter 1 Getting Started Introduction The Symbol CS3000 Series Scanner captures and stores bar codes for a variety of uses, and transmits bar code data to a host via USB connection or Bluetooth. Scan Button Delete Button Bluetooth Button/LED Mini-USB Port...
  • Page 16: Unpacking The Scanner

    1 - 2 Symbol CS3000 Series Scanner Product Reference Guide Unpacking the Scanner Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, contact Motorola Enterprise Mobility Support. See page xiii for contact information. KEEP THE PACKING. It is the approved shipping container and should be used if the equipment ever needs to be returned for servicing.
  • Page 17: Charging The Scanner Battery

    Getting Started 1 - 3 Charging the Scanner Battery To charge the CS3000 series scanner, connect it to a host PC via the USB host cable or charging cradle. No power supply is necessary. Charge time is approximately three hours for a fully discharged battery. NOTE To check the battery charge status, hold the scan (+) button for 15 seconds.
  • Page 18: Charging Via Charging Cradle

    1 - 4 Symbol CS3000 Series Scanner Product Reference Guide The scanner begins charging. A complete charge of a fully discharged battery takes approximately three hours. Charge within the recommended temperature of 32° to 104° F (0° to 40° C).
  • Page 19: Scanner Charging Led

    Getting Started 1 - 5 Scanner Charging LED The scanner’s LED indicates charging activity (see Table 2-1 on page 2-3). The amber LED blinks slowly during charging. The scanner’s LED turns solid green when the battery is fully charged. Connecting to the Host Computer Batch Connection Charging the Scanner Battery on page 1-3 for instructions on connecting the scanner to a host PC via USB.
  • Page 20: Bluetooth Connection Examples

    Press the scan button (+) to wake the scanner. Press and hold the Bluetooth button (round button with Motorola logo) for five seconds. The scanner beeps and the Bluetooth button starts blinking quickly to indicate that the scanner is discoverable by the host.
  • Page 21 Getting Started 1 - 7 Place the application into discover Bluetooth device mode (in this example, select the check box), and click Next Sample Device Discovery Window Figure 1-9 Select the CS3070 device from the discovered device list. The Bluetooth application may prompt you to scan a passkey it generated, or for you to create and then scan a passkey (PIN).
  • Page 22 1 - 8 Symbol CS3000 Series Scanner Product Reference Guide Select an option, then click Next • If you select , the host generates and displays a passkey. Choose a passkey for me • If you select , enter the default...
  • Page 23 Getting Started 1 - 9 Click to complete the pairing. The device appears in the window. Finish Bluetooth Devices Bluetooth Devices Window Figure 1-12 Select the device, then click The CS3070 issues a two-tone beep and the Bluetooth button blinks slowly Add...
  • Page 24 1 - 10 Symbol CS3000 Series Scanner Product Reference Guide On the host PC, launch the third party Bluetooth pairing application. Following is a sample window of such an application. Sample Bluetooth Application Window Figure 1-13 Place the application into discover Bluetooth device mode (in this example, select the check box), and click...
  • Page 25 Getting Started 1 - 11 Select the CS3070 device from the discovered device list. The Bluetooth application may prompt you to scan a passkey it generated, or for you to create and then scan a passkey (PIN). Sample Passkey Option Window Figure 1-15 For SPP, select , then enter the default passkey...
  • Page 26 Press the scan button (+) to wake the scanner. Press and hold the Bluetooth button (round button with Motorola logo) for five seconds. The scanner beeps and the Bluetooth button starts blinking quickly to indicate that the scanner is discoverable by the Motorola ES400.
  • Page 27 Getting Started 1 - 13 . The ES400 searches for Bluetooth devices. Add new device... Sample Device Discovery Window Figure 1-18 Select the CS3070 device from the discovered device list and tap . The device prompts you to enter a Next passcode.
  • Page 28 1 - 14 Symbol CS3000 Series Scanner Product Reference Guide If you entered a passcode in Step 6, scan Numeric Bar Codes for PIN Entry on page 1-21 corresponding to that code, then scan the bar code. Enter Connection Verification Window...
  • Page 29 NOTE Bluetooth pairing suspends temporarily while charging via a USB cable. Disconnecting the cable automatically re-establishes the Bluetooth pairing. Windows Mobile Device (Motorola ES400) SPP Pairing Example For CS3070 scanners, to pair to a Motorola ES400 Windows Mobile 6.5 device via SPP: Press the scan button (+) to wake the scanner. Scan Bluetooth Serial Port Profile (SPP) on page 3-13.
  • Page 30 1 - 16 Symbol CS3000 Series Scanner Product Reference Guide On the ES400, launch the third party Bluetooth pairing application. Following is a sample window of such an application. Sample Bluetooth Application Window - Add Device Window Figure 1-23 . The ES400 searches for Bluetooth devices.
  • Page 31 Getting Started 1 - 17 Select the CS3070 device from the discovered device list and tap . The device prompts you to enter a Next passcode. Sample Enter Passcode Window Figure 1-25...
  • Page 32 1 - 18 Symbol CS3000 Series Scanner Product Reference Guide Enter the CS3070 default PIN (1234) and tap Next Connection Verification Window Figure 1-26 NOTE For SPP, the host requires entering a PIN, but no PIN entry is required for the CS3070.
  • Page 33 Getting Started 1 - 19 Select the device and tap . The window appears. Connect Partnership Settings Partnership Settings Window Figure 1-28 and then to complete the pairing. The device appears in the list, and the Serial Port Save Connected CS3070 issues a two-tone beep and the Bluetooth button blinks slowly to indicate that the scanner paired with the ES400.
  • Page 34 1 - 20 Symbol CS3000 Series Scanner Product Reference Guide NOTE Bluetooth pairing suspends temporarily while charging via a USB cable. Disconnecting the cable automatically re-establishes the Bluetooth pairing. Unpairing To temporarily unpair the scanner and host, press the Bluetooth button. This disables Bluetooth and the Bluetooth button stops blinking.
  • Page 35: Numeric Bar Codes For Pin Entry

    Getting Started 1 - 21 Numeric Bar Codes for PIN Entry Use the following bar codes for pin entry for Bluetooth connection. Enter...
  • Page 36: Configuring The Scanner

    1 - 22 Symbol CS3000 Series Scanner Product Reference Guide Configuring the Scanner To configure the scanner for initial use: Scan the parameter bar codes in Chapter 3, User Preferences Chapter 4, Symbologies to customize scanner operation. Scan the Save Configuration bar code on page 3-22 (also provided below).
  • Page 37: Editing The Configuration File

    Getting Started 1 - 23 Editing the Configuration File Use a text editor such as Notepad to set configuration values in the editable text file in the Config.ini \Parameters folder on the CS30XX. Table 1-1 lists the programmable contents of the file. NOTE If you make errors while editing the Config.ini file, the file LOG.TXT is created in the \Parameters folder.
  • Page 38 1 - 24 Symbol CS3000 Series Scanner Product Reference Guide Config.ini File Content (Continued) Table 1-1 Parameter Values Description Default ScanParam Variable Any scan engine parameter. Multiple <none> entries are allowed. Sent after reset or when engine is powered. For example:...
  • Page 39: Chapter 2: Scanning

    Chapter 2 Scanning Introduction This chapter provides instructions for how to scan bar codes and send the data to a host. Beeper and LED definitions are also included. Scanning Chapter 1, Getting Started to install and program the scanner. To scan: Aim the scanner at the bar code.
  • Page 40: Deleting Bar Codes

    2 - 2 Symbol CS3000 Series Scanner Product Reference Guide The scanner beeps and the LED turns green to indicate a successful decode. See Table 2-1 Table 2-2 beeper and LED definitions. NOTE The scanner cannot scan bar codes when it is connected to the host via the USB host cable.
  • Page 41: User Interface Definitions

    Scanning 2 - 3 Out of Range Behavior If the scanner moves out of range of the host and does not re-pair with the host within the timeout period, it stores data in a batch file. This data must be manually copied to the host. Within this timeout period, the scanner does not decode and emits four error beeps in response to scan attempts.
  • Page 42 2 - 4 Symbol CS3000 Series Scanner Product Reference Guide LED Indications (Continued) Table 2-1 Function Performed User Action LED Feedback Other Toggle data protection on or off Press & hold both None (when enabled) scan (+) and delete (-) buttons...
  • Page 43: Beeper Indications

    Scanning 2 - 5 LED Indications (Continued) Table 2-1 Function Performed User Action LED Feedback Other Data protection (enabled and on) Scan/function/ host Rapidly flashing red Unexpected failure Scan/function/dock Flashing red, green Contact support and amber for 5 seconds Battery depleted Scan/function/dock None Beeper Indications Beeper Indications...
  • Page 44 2 - 6 Symbol CS3000 Series Scanner Product Reference Guide...
  • Page 45: Chapter 3 User Preferences

    Chapter 3 User Preferences Introduction This chapter describes each user preference feature and provides the programming bar codes for selecting these features for the scanner. The scanner ships with the settings shown in the User Preferences Default Table on page 3-2 (also see Appendix A, Standard Default Parameters...
  • Page 46: User Preferences Default Parameters

    3 - 2 Symbol CS3000 Series Scanner Product Reference Guide User Preferences Default Parameters Table 3-1 lists the defaults for user preference parameters. To change any option, scan the appropriate bar code(s) provided in this chapter. NOTE See Appendix A, Standard Default Parameters for all default parameters.
  • Page 47 User Preferences 3 - 3 User Preferences Default Table (Continued) Table 3-1 Parameter Number Page Parameter Factory Default (Hex) Number Send Bluetooth Version 3-21 Send Scan Engine Version 3-21 3-22 Save Configuration...
  • Page 48: Reset

    3 - 4 Symbol CS3000 Series Scanner Product Reference Guide Reset To reset the scanner and apply parameters from the configuration file, scan the following bar code. Reset Reset Factory Defaults To reset the scanner to factory defaults, scan the following bar code. This rebuilds the configuration file from program memory.
  • Page 49: Set Date And Time

    User Preferences 3 - 5 Set Date and Time NOTE You must scan the configuration bar codes to set the time and date stamp on the scanner. The time and date can not be set or edited in the config.ini file. This setting persists for three months if the scanner is not used.
  • Page 50: Numeric Bar Codes For Date And Time Settings

    3 - 6 Symbol CS3000 Series Scanner Product Reference Guide Numeric Bar Codes for Date and Time Settings Enter...
  • Page 51: Clear Data

    User Preferences 3 - 7 Clear Data Scan the following bar code to clear all batch bar code data on the scanner. This deletes the BarcodeFile.txt from the scanner. Clear Data...
  • Page 52: Beeper Settings

    3 - 8 Symbol CS3000 Series Scanner Product Reference Guide Beeper Settings Beeper Volume Parameter # 0x8C To select a decode beep volume, scan the appropriate bar code. (0x02) *Medium (0x01) High (0x00)
  • Page 53: Beeper Tone

    User Preferences 3 - 9 Beeper Tone Parameter # 0x91 To select a decode beep frequency (tone), scan the appropriate bar code. Low Frequency (0x02) *Medium Frequency (0x01) High Frequency (0x00)
  • Page 54: Mute Beeper

    3 - 10 Symbol CS3000 Series Scanner Product Reference Guide Mute Beeper Scan the bar code to mute the beeper. Mute Beeper Mute Beeper (0x01) *Do Not Mute Beeper (0x00)
  • Page 55: Scanner Options

    User Preferences 3 - 11 Scanner Options Scan Angle Parameter # 0xBF This parameter sets the scan angle to narrow or wide. Narrow Angle (35°) (0x05) *Wide Angle (47°) (0x06) NOTE The allowed values for this setting are different for some legacy models of scanners. These old values can still be used and are interpreted by the scanner as follows.
  • Page 56: Transmit "No Read" Message

    3 - 12 Symbol CS3000 Series Scanner Product Reference Guide Transmit “No Read” Message Parameter # 0x5E Enable this option to transmit “NR” if a symbol does not decode during the timeout period or before the trigger is released. Any enabled prefix or suffixes are appended around this message.
  • Page 57: Bluetooth Options

    User Preferences 3 - 13 Bluetooth Options Bluetooth Unpair Scan the following bar code to unpair the scanner from the host. Unpair Bluetooth HID Profile Scan to cause the scanner to emulate a keyboard. Bluetooth HID Profile Bluetooth HID Profile Bluetooth Serial Port Profile (SPP) Scan to cause the scanner to emulate a serial connection.
  • Page 58: Disable All Symbologies

    3 - 14 Symbol CS3000 Series Scanner Product Reference Guide Disable All Symbologies Scan the bar code below to disable the decoding of all symbologies. Use this to simplify selecting a single symbology to decode by scanning this, then scanning the desired enable code type bar code. Note that the scanner can still decode parameter bar codes.
  • Page 59: Linear Code Type Security Level

    User Preferences 3 - 15 Linear Code Type Security Level Parameter # 0x4E The scanner offers four levels of decode security for linear code types (e.g., Code 39, Interleaved 2 of 5). Select higher security levels for decreasing levels of bar code quality. As security levels increase, the scanner’s aggressiveness decreases.
  • Page 60: Bi-Directional Redundancy

    3 - 16 Symbol CS3000 Series Scanner Product Reference Guide Linear Security Level 3 The scanner must read code types other than the following twice before decoding. It must read the following codes three times: Code Type Length 4 or less...
  • Page 61: Data Options

    User Preferences 3 - 17 Data Options Transmit Code ID Character Parameter # 0x2D A code ID character identifies the code type of a scanned bar code. This can be useful when decoding more than one code type. The code ID character is inserted between the prefix character (if selected) and the decoded symbol.
  • Page 62: Prefix/Suffix Values

    3 - 18 Symbol CS3000 Series Scanner Product Reference Guide Prefix/Suffix Values Parameter # P = 0x69, S1 = 0x68, S2 = 0x6A Append a prefix and/or one or two suffixes to scan data for data editing. To set these values, scan a four-digit number (i.e., four bar codes) that corresponds to ASCII values.
  • Page 63: Scan Data Transmission Format

    User Preferences 3 - 19 Scan Data Transmission Format Parameter # 0xEB To change the Scan Data Transmission Format, scan one of the following bar codes corresponding to the desired format. *Data As Is (0x00) <DATA> <SUFFIX 1> (0x01) <DATA> <SUFFIX 2> (0x02) <DATA>...
  • Page 64 3 - 20 Symbol CS3000 Series Scanner Product Reference Guide Scan Data Transmission Format (continued) <PREFIX> <DATA > (0x04) <PREFIX> <DATA> <SUFFIX 1> (0x05) <PREFIX> <DATA> <SUFFIX 2> (0x06) <PREFIX> <DATA> <SUFFIX 1> <SUFFIX 2> (0x07)
  • Page 65: Send Versions

    User Preferences 3 - 21 Send Versions Firmware Version Scan the following bar code to send the firmware version to the host. Firmware Version Bluetooth Version Scan the following bar code to send the Bluetooth version to the host. Bluetooth Version Scan Engine Version Scan the following bar code to send the scan engine version to the host.
  • Page 66: Save Configuration

    3 - 22 Symbol CS3000 Series Scanner Product Reference Guide Save Configuration Scan the following bar code after setting parameters to save the new configuration selections. Save Configuration...
  • Page 67: Chapter 4 Symbologies

    Chapter 4 Symbologies Introduction This chapter describes symbology features and provides the programming bar codes for selecting these features for the scanner. Before programming, follow the instructions in Chapter 1, Getting Started. The scanner ships with the settings in Table 4-1 on page 4-2 (also see Appendix A, Standard Default Parameters for all scanner defaults).
  • Page 68: Symbology Default Parameters

    4 - 2 Symbol CS3000 Series Scanner Product Reference Guide Symbology Default Parameters Table 4-1 lists the defaults for all symbologies parameters. To change any option, scan the appropriate bar code(s) in this chapter. NOTE See Appendix A, Standard Default Parameters for all default parameters.
  • Page 69 Symbologies 4 - 3 Factory Default Table (Continued) Table 4-1 Parameter Number Page Parameter Factory Default (Hex) Number Code 128 Code 128 0x08 Enable 4-21 GS1-128 (formerly UCC/EAN-128) 0x0E Enable 4-22 ISBT 128 0x54 Enable 4-22 Code 39 Code 39 0x00 Enable 4-23...
  • Page 70 4 - 4 Symbol CS3000 Series Scanner Product Reference Guide Factory Default Table (Continued) Table 4-1 Parameter Number Page Parameter Factory Default (Hex) Number Discrete 2 of 5 Discrete 2 of 5 0x05 Disable 4-37 Set Length(s) for D 2 of 5...
  • Page 71: Upc/Ean

    Symbologies 4 - 5 UPC/EAN Enable/Disable UPC-A Parameter # 0x01 To enable or disable UPC-A, scan the appropriate bar code below. *Enable UPC-A (0x01) Disable UPC-A (0x00) Enable/Disable UPC-E Parameter # 0x02 To enable or disable UPC-E, scan the appropriate bar code below. *Enable UPC-E (0x01) Disable UPC-E...
  • Page 72: Enable/Disable Upc-E1

    4 - 6 Symbol CS3000 Series Scanner Product Reference Guide Enable/Disable UPC-E1 Parameter # 0x0C To enable or disable UPC-E1, scan the appropriate bar code below. NOTE UPC-E1 is not a UCC (Uniform Code Council) approved symbology. Enable UPC-E1 (0x01)
  • Page 73: Enable/Disable Ean-13

    Symbologies 4 - 7 Enable/Disable EAN-13 Parameter # 0x03 To enable or disable EAN-13, scan the appropriate bar code below. *Enable EAN-13 (0x01) Disable EAN-13 (0x00) Enable/Disable Bookland EAN Parameter # 0x53 To enable or disable EAN Bookland, scan the appropriate bar code below. Enable Bookland EAN (0x01) *Disable Bookland EAN...
  • Page 74: Decode Upc/Ean Supplementals

    4 - 8 Symbol CS3000 Series Scanner Product Reference Guide Decode UPC/EAN Supplementals Parameter # 0x10 Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). The following options are available: • If you select Ignore UPC/EAN Supplementals, and the scanner is presented with a UPC/EAN plus supplemental symbol, the scanner decodes UPC/EAN and ignores the supplemental characters.
  • Page 75 Symbologies 4 - 9 Decode UPC/EAN Supplementals (continued) Select the desired option by scanning one of the following bar codes. Decode UPC/EAN Supplementals (0x01) *Ignore UPC/EAN With Supplementals (0x00) Autodiscriminate UPC/EAN Supplementals (0x02) Enable 378/379 Supplemental Mode (0x04) Enable 978/979 Supplemental Mode (0x05)
  • Page 76 4 - 10 Symbol CS3000 Series Scanner Product Reference Guide Decode UPC/EAN Supplementals (continued) Enable 977 Supplemental Mode (0x07) Enable 414/419/434/439 Supplemental Mode (0x06) Enable 491 Supplemental Mode (0x08) Enable Smart Supplemental Mode (0x03)
  • Page 77 Symbologies 4 - 11 Decode UPC/EAN Supplementals (continued) Supplemental User-Programmable Type 1 (0x09) Supplemental User-Programmable Type 1 and 2 (0x0A) Smart Supplemental Plus User-Programmable 1 (0x0B) Smart Supplemental Plus User-Programmable 1 and 2 (0x0C)
  • Page 78: User-Programmable Supplementals

    4 - 12 Symbol CS3000 Series Scanner Product Reference Guide User-Programmable Supplementals Supplemental 1: Parameter # 0xF1 0x43 Supplemental 2: Parameter # 0xF1 0x44 If you selected a Supplemental User-Programmable option from Decode UPC/EAN Supplementals on page 4-8, select User-Programmable Supplemental 1 to set the 3-digit prefix. Then select the 3 digits using the Numeric Bar Codes on page 4-48.
  • Page 79: Transmit Upc-A Check Digit

    Symbologies 4 - 13 Transmit UPC-A Check Digit Parameter # 0x28 Scan the appropriate bar code below to transmit the symbol with or without the UPC-A check digit. *Transmit UPC-A Check Digit (0x01) Do Not Transmit UPC-A Check Digit (0x00) Transmit UPC-E Check Digit Parameter # 0x29 Scan the appropriate bar code below to transmit the symbol with or without the UPC-E check digit.
  • Page 80: Transmit Upc-E1 Check Digit

    4 - 14 Symbol CS3000 Series Scanner Product Reference Guide Transmit UPC-E1 Check Digit Parameter # 0x2A Scan the appropriate bar code below to transmit the symbol with or without the UPC-E1 check digit. *Transmit UPC-E1 Check Digit (0x01) Do Not Transmit UPC-E1 Check Digit...
  • Page 81: Upc-E Preamble

    Symbologies 4 - 15 UPC-E Preamble Parameter # 0x23 Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-E symbol. Select one of the following options for transmitting UPC-E preamble to the host device: transmit system character only, transmit system character and country code (“0”...
  • Page 82: Upc-E1 Preamble

    4 - 16 Symbol CS3000 Series Scanner Product Reference Guide UPC-E1 Preamble Parameter # 0x24 Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-E1 symbol. Select one of the following options for transmitting UPC-E1 preamble to the host device: transmit system character only, transmit system character and country code (“0”...
  • Page 83: Convert Upc-E To Upc-A

    Symbologies 4 - 17 Convert UPC-E to UPC-A Parameter # 0x25 Enable this parameter to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
  • Page 84: Ean Zero Extend

    4 - 18 Symbol CS3000 Series Scanner Product Reference Guide EAN Zero Extend Parameter # 0x27 When enabled, this parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. Disable this parameter to transmit EAN-8 symbols as is.
  • Page 85: Bookland Isbn Format

    Symbologies 4 - 19 Bookland ISBN Format Parameter # 0xF1 0x40 If you enabled Bookland EAN using Enable/Disable Bookland EAN on page 4-7, select one of the following formats for Bookland data: • Bookland ISBN-10 - The scanner reports Bookland data starting with 978 in traditional 10-digit format with the special Bookland check digit for backward-compatibility.
  • Page 86: Upc/Ean Security Level

    4 - 20 Symbol CS3000 Series Scanner Product Reference Guide UPC/EAN Security Level Parameter # 0x4D The Symbol CS3070 offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. Select higher levels of security for decreasing levels of bar code quality.
  • Page 87: Ucc Coupon Extended Code

    Symbologies 4 - 21 UCC Coupon Extended Code Parameter # 0x55 The UCC Coupon Extended Code is an additional bar code adjacent to a UCC Coupon Code. To enable or disable UCC Coupon Extended Code, scan the appropriate bar code below. Enable UCC Coupon Extended Code (0x01) Disable UCC Coupon Extended Code...
  • Page 88: Enable/Disable Gs1-128 (Formerly Ucc/Ean-128)

    4 - 22 Symbol CS3000 Series Scanner Product Reference Guide Enable/Disable GS1-128 (formerly UCC/EAN-128) Parameter # 0x0E To enable or disable GS1-128, scan the appropriate bar code below. See Appendix B, Programming Reference details on GS1-128 (formerly UCC/EAN-128). *Enable GS1-128...
  • Page 89: Code 39

    Symbologies 4 - 23 Code 39 Enable/Disable Code 39 Parameter # 0x00 To enable or disable Code 39, scan the appropriate bar code below. *Enable Code 39 (0x01) Disable Code 39 (0x00) Enable/Disable Trioptic Code 39 Parameter # 0x0D Trioptic Code 39 is a variant of Code 39 used in marking computer tape cartridges. Trioptic Code 39 symbols always contain six characters.
  • Page 90: Convert Code 39 To Code 32 (Italian Pharma Code)

    4 - 24 Symbol CS3000 Series Scanner Product Reference Guide Convert Code 39 to Code 32 (Italian Pharma Code) Parameter # 0x56 Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32.
  • Page 91: Set Lengths For Code 39

    Symbologies 4 - 25 Set Lengths for Code 39 Parameter # L1 = 0x12, L2 = 0x13 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 39 to any length, one or two discrete lengths, or lengths within a specific range.
  • Page 92: Code 39 Check Digit Verification

    4 - 26 Symbol CS3000 Series Scanner Product Reference Guide Code 39 Check Digit Verification Parameter # 0x30 Enable this feature to check the integrity of all Code 39 symbols to verify that the data complies with a specified check digit algorithm. Only Code 39 symbols that include a modulo 43 check digit are decoded, so only enable this if your Code 39 symbols contain a module 43 check digit.
  • Page 93: Enable/Disable Code 39 Full Ascii

    Symbologies 4 - 27 Enable/Disable Code 39 Full ASCII Parameter # 0x11 Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. Table B-6 on page B-7 for mapping Code 39 characters to ASCII values.
  • Page 94: Code 93

    4 - 28 Symbol CS3000 Series Scanner Product Reference Guide Code 93 Enable/Disable Code 93 Parameter # 0x09 To enable or disable Code 93, scan the appropriate bar code below. Enable Code 93 (0x01) *Disable Code 93 (0x00) Set Lengths for Code 93 Parameter # L1 = 0x1A, L2 = 0x1B The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s)
  • Page 95 Symbologies 4 - 29 Two Discrete Lengths - Select this option to decode only codes containing two selected lengths. For example, select Code 93 Two Discrete Lengths, then scan 0, 2, 1, 4 from Numeric Bar Codes on page 4-48 to limit the decoding to Code 93 symbols containing 2 or 14 characters.
  • Page 96: Code 11

    4 - 30 Symbol CS3000 Series Scanner Product Reference Guide Code 11 Enable/Disable Code 11 Parameter # 0x0A To enable or disable Code 11, scan the appropriate bar code below. Enable Code 11 (0x01) Disable Code 11 (0x00) Set Lengths for Code 11 Parameter # L1 = 0x1C, L2 = 0x1D The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s)
  • Page 97 Symbologies 4 - 31 Set Lengths for Code 11 (continued) Code 11 - One Discrete Length Code 11 - Two Discrete Lengths Code 11 - Length Within Range Code 11 - Any Length...
  • Page 98: Code 11 Check Digit Verification

    4 - 32 Symbol CS3000 Series Scanner Product Reference Guide Code 11 Check Digit Verification Parameter # 0x34 This feature allows the scanner to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar code. The options are to check for one check digit, check for two check digits, or disable the feature.
  • Page 99: Transmit Code 11 Check Digits

    Symbologies 4 - 33 Transmit Code 11 Check Digits Parameter # 0x2F This feature selects whether or not to transmit the Code 11 check digit(s). Transmit Code 11 Check Digit(s) (Enable) (0x01) Do Not Transmit Code 11 Check Digit(s) (Disable) (0x00) NOTE Code 11 Check Digit Verification must be enabled for this parameter to function.
  • Page 100: Set Lengths For Interleaved 2 Of 5

    4 - 34 Symbol CS3000 Series Scanner Product Reference Guide Set Lengths for Interleaved 2 of 5 Parameter # L1 = 0x16, L2 = 0x17 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
  • Page 101 Symbologies 4 - 35 Set Lengths for Interleaved 2 of 5 (continued) Length Within Range - Select this option to decode only codes within a specified range. For example, to decode I 2 of 5 symbols containing between 4 and 12 characters, first scan I 2 of 5 Length Within Range, then scan 0, 4, 1 and 2 (include a leading zero for single digit numbers).
  • Page 102: I 2 Of 5 Check Digit Verification

    4 - 36 Symbol CS3000 Series Scanner Product Reference Guide I 2 of 5 Check Digit Verification Parameter # 0x31 When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm, either USS (Uniform Symbology Specification), or OPCC (Optical Product Code Council).
  • Page 103: Convert I 2 Of 5 To Ean-13

    Symbologies 4 - 37 Convert I 2 of 5 to EAN-13 Parameter # 0x52 This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. To accomplish this, first enable I 2 of 5, set one length to 14, and include a leading zero and a valid EAN-13 check digit in the code.
  • Page 104: Set Lengths For Discrete 2 Of 5

    4 - 38 Symbol CS3000 Series Scanner Product Reference Guide Set Lengths for Discrete 2 of 5 Parameter # L1 = 0x14, L2 = 0x15 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
  • Page 105: Chinese 2 Of 5

    Symbologies 4 - 39 Chinese 2 of 5 Enable/Disable Chinese 2 of 5 Parameter # 0xF0 0x98 To enable or disable Chinese 2 of 5, scan the appropriate bar code below. Enable Chinese 2 of 5 (0x01) Disable Chinese 2 of 5 (0x00) Codabar Enable/Disable Codabar...
  • Page 106: Set Lengths For Codabar

    4 - 40 Symbol CS3000 Series Scanner Product Reference Guide Set Lengths for Codabar Parameter # L1 = 0x18, L2 = 0x19 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
  • Page 107: Clsi Editing

    Symbologies 4 - 41 CLSI Editing Parameter # 0x36 Enable this to strip the start and stop characters and insert a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. NOTE Symbol length does not include start and stop characters. Enable CLSI Editing (0x01) *Disable CLSI Editing...
  • Page 108: Msi

    4 - 42 Symbol CS3000 Series Scanner Product Reference Guide Enable/Disable MSI Parameter # 0x0B To enable or disable MSI, scan the appropriate bar code below. Enable MSI (0x01) *Disable MSI (0x00)
  • Page 109: Set Lengths For Msi

    Symbologies 4 - 43 Set Lengths for MSI Parameter # L1 = 0x1E, L2 = 0x1F The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits. Set lengths for MSI to any length, one or two discrete lengths, or lengths within a specific range.
  • Page 110: Msi Check Digits

    4 - 44 Symbol CS3000 Series Scanner Product Reference Guide MSI Check Digits Parameter # 0x32 These check digits at the end of the bar code verify the integrity of the data. At least one check digit is always required. Check digits are not automatically transmitted with the data.
  • Page 111: Msi Check Digit Algorithm

    Symbologies 4 - 45 MSI Check Digit Algorithm Parameter # 0x33 MSI Check Digits on page 4-44 is set to , an additional verification is required to ensure integrity. Select one of the following algorithms. MOD 10/ MOD 11 (0x00) *MOD 10/ MOD 10 (0x01) GS1 DataBar...
  • Page 112: Enable/Disable Gs1 Databar Limited

    4 - 46 Symbol CS3000 Series Scanner Product Reference Guide Enable/Disable GS1 DataBar Limited Parameter # 0xF0 0x53 To enable or disable GS1 DataBar Limited, scan the appropriate bar code below. Enable GS1 DataBar Limited (0x01) *Disable GS1 DataBar Limited...
  • Page 113: Convert Gs1 Databar To Upc/Ean

    Symbologies 4 - 47 Convert GS1 DataBar to UPC/EAN Parameter # 0xF0 0x8D This parameter only applies to GS1 DataBar-14 and GS1 DataBar Limited symbols. Enable this conversion to strip the leading from GS1 DataBar-14 and GS1 DataBar Limited symbols encoding a single zero as the first digit, and report the bar code as EAN-13.
  • Page 114: Numeric Bar Codes

    4 - 48 Symbol CS3000 Series Scanner Product Reference Guide Numeric Bar Codes For parameters requiring specific numeric values, use the following bar codes. NOTE These bar codes differ from the Numeric Bar Codes for PIN Entry on page 1-21...
  • Page 115 Symbologies 4 - 49 Numeric Bar Codes (continued)
  • Page 116: Cancel

    4 - 50 Symbol CS3000 Series Scanner Product Reference Guide Cancel In case of an error or to change the selection, scan the bar code below. Cancel...
  • Page 117: Chapter 5 Maintenance And Technical Specifications

    Chapter 5 Maintenance and Technical Specifications Introduction This chapter provides suggested scanner maintenance, troubleshooting, and technical specifications. Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy. • Do not allow any abrasive material to touch the window. •...
  • Page 118: Troubleshooting

    NOTE If problems still occur, contact the distributor or Motorola Enterprise Mobility Support. See page xiii contact information. Before contacting support, view the sysinfo.txt file in the \Parameters folder on the CS30XX. This indicates the device’s serial number, software version, Bluetooth version, and scan engine version and is...
  • Page 119: Technical Specifications

    Maintenance and Technical Specifications 5 - 3 Technical Specifications Technical Specifications - Scanner Table 5-2 Description Item Symbol CS3000 Symbol CS3070 Battery Rechargeable Lithium-Ion 2200 mAh (3.7V) Power Consumption 5V, 500mA max while charging Decode Capability UPC/EAN, Bookland EAN, UPC/EAN with supplementals, Code 128, UCC/EAN 128, ISBT 128, Code 39, Trioptic Code 39, Code 93, Code 11, Interleaved 2 of 5, Discrete 2 of 5, Codabar (NW-7), MSI, GS1 DataBar.
  • Page 120 5 - 4 Symbol CS3000 Series Scanner Product Reference Guide Technical Specifications - Scanner (Continued) Table 5-2 Description Item Symbol CS3000 Symbol CS3070 Minimum Element Width 5 mil (0.127 mm) 7.5 mil (0.191 mm) Decode Ranges 4 mil: 0.9” - 4.9”...
  • Page 121: Decode Zone

    Maintenance and Technical Specifications 5 - 5 Decode Zone Note: Typical performance at 73.4 F (23 C) In . on high quality symbols. 38.1 3 1 .6 12.7 CS3000 12.7 4 mil 0.90 4.90 25.4 5 mil 1.20 7.40 7.5 mil 1.60 12.40 10 mil...
  • Page 122 5 - 6 Symbol CS3000 Series Scanner Product Reference Guide...
  • Page 123: Appendix A Standard Default Parameters

    Appendix A Standard Default Parameters Default Table Table A-1 Parameter Number Page Parameter Factory Default (Hex) Number User Preferences Reset Reset Factory Defaults Set Date Set Time Cancel Date and Time Settings Clear Data Beeper Volume 0x8C Medium Beeper Tone 0x91 Medium Frequency Mute Beeper...
  • Page 124 A - 2 Symbol CS3000 Series Scanner Product Reference Guide Default Table (Continued) Table A-1 Parameter Number Page Parameter Factory Default (Hex) Number Data Options Transmit Code ID Character 0x2D None 3-17 Prefix/Suffix Values 3-18 Prefix 0x69 NULL Suffix 1...
  • Page 125 Standard Default Parameters A - 3 Default Table (Continued) Table A-1 Parameter Number Page Parameter Factory Default (Hex) Number Convert UPC-E to A 0x25 Disable 4-17 Convert UPC-E1 to A 0x26 Disable 4-17 EAN-8 Zero Extend 0x27 Disable 4-18 Bookland ISBN Format 0xF1 0x40 ISBN-10 4-19...
  • Page 126 A - 4 Symbol CS3000 Series Scanner Product Reference Guide Default Table (Continued) Table A-1 Parameter Number Page Parameter Factory Default (Hex) Number Interleaved 2 of 5 Interleaved 2 of 5 0x06 Enable 4-33 Set Length(s) for I 2 of 5...
  • Page 127 Standard Default Parameters A - 5 Default Table (Continued) Table A-1 Parameter Number Page Parameter Factory Default (Hex) Number GS1 DataBar GS1 DataBar-14 0xF0 Disable 4-45 0x52 GS1 DataBar Limited 0xF0 Disable 4-46 0x53 GS1 DataBar Expanded 0xF0 Disable 4-46 0x54 Convert GS1 DataBar to UPC/EAN 0xF0...
  • Page 128 A - 6 Symbol CS3000 Series Scanner Product Reference Guide...
  • Page 129: Appendix B Programming Reference

    Appendix B Programming Reference Code Type IDs Code Type IDs Table B-1 Code Type Hex Value Code Type Hex Value Not Applicable 0x00 EAN-8 with 2 Supps. 0x4A Code 39 0x01 EAN-8 with 5 Supps. 0x8A Codabar 0x02 EAN-13 0x0B Code 128 0x03 EAN-13 with 2 Supps.
  • Page 130: Symbol Code Identifiers

    B - 2 Symbol CS3000 Series Scanner Product Reference Guide Symbol Code Identifiers Symbol Code Characters Table B-2 Code Character Code Type UPC/EAN Code 39, Code 39 Full ASCII, Code 32 Codabar Code 128, ISBT 128 Code 93 Interleaved 2 of 5...
  • Page 131: Aim Code Identifiers

    Programming Reference B - 3 AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: Flag Character (ASCII 93) Code Character (see Table B-3) Modifier Character (see Table B-4) Aim Code Characters Table B-3 Code Character Code Type Code 39, Code 39 Full ASCII, Code 32 Code 128 (all variants) UPC/EAN...
  • Page 132 B - 4 Symbol CS3000 Series Scanner Product Reference Guide The modifier character is the sum of the applicable option values based on Table B-4. Modifier Characters Table B-4 Code Type Option Value Option Code 39 No check character or Full ASCII processing.
  • Page 133 Programming Reference B - 5 Modifier Characters (Continued) Table B-4 Code Type Option Value Option Check digits are sent. No check digit is sent. Example: An MSI bar code 4123, with a single check digit checked, is transmitted as ]M14123. D 2 of 5 No options specified at this time.
  • Page 134: Gs1-128 (Formerly Ucc/Ean-128

    B - 6 Symbol CS3000 Series Scanner Product Reference Guide GS1-128 (formerly UCC/EAN-128) GS1-128 is a convention for printing data fields with standard Code 128 bar code symbols. GS1-128 symbols are distinguished by a leading FNC 1 character as the first or second character in the symbol. Other FNC 1 characters are used to delineate fields.
  • Page 135: Setting Prefixes And Suffixes

    Programming Reference B - 7 Setting Prefixes and Suffixes To append a prefix and suffixes to the decode data: Set the Scan Data Transmission Format (parameter 0xE2) to the desired option. Enter the required value(s) for Prefix (0x69), Suffix1 (0x68) or Suffix2 (0x6A) using the hex values for the desired ASCII value from Table B-6.
  • Page 136 B - 8 Symbol CS3000 Series Scanner Product Reference Guide Character Equivalents (Continued) Table B-6 Full ASCII Code 39 Scan Value Hex Value Keystroke Encode Char. 1024 CTRL X 1025 CTRL Y 1026 CTRL Z 1027 CTRL [ 1028 CTRL \...
  • Page 137 Programming Reference B - 9 Character Equivalents (Continued) Table B-6 Full ASCII Code 39 Scan Value Hex Value Keystroke Encode Char. 1053 1054 1055 1056 1057 1058 1059 1060 < 1061 1062 > 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072...
  • Page 138 B - 10 Symbol CS3000 Series Scanner Product Reference Guide Character Equivalents (Continued) Table B-6 Full ASCII Code 39 Scan Value Hex Value Keystroke Encode Char. 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 ‘...
  • Page 139 Programming Reference B - 11 Character Equivalents (Continued) Table B-6 Full ASCII Code 39 Scan Value Hex Value Keystroke Encode Char. 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 Undefined Values from 1128 through 1255 may also be set.
  • Page 140 B - 12 Symbol CS3000 Series Scanner Product Reference Guide...
  • Page 141: Appendix C Sample Bar Codes

    Appendix C Sample Bar Codes UPC-A 12345 67890 UPC-E 123456...
  • Page 142: Upc-E1

    C - 2 Symbol CS3000 Series Scanner Product Reference Guide UPC-E1 NOTE To enable this symbology in order to scan the sample, see Enable/Disable UPC-E1 on page 4-6. 123456 EAN-13 3 456789 012340 EAN-8 1234 5670 Code 39 123ABC...
  • Page 143: Trioptic Code 39

    Sample Bar Codes C - 3 Trioptic Code 39 NOTE To enable this symbology in order to scan the sample, see Enable/Disable Trioptic Code 39 on page 4-23. 456123 Code 93 NOTE To enable this symbology in order to scan the sample, see Enable/Disable Code 93 on page 4-28.
  • Page 144: Codabar

    C - 4 Symbol CS3000 Series Scanner Product Reference Guide Codabar NOTE To enable this symbology in order to scan the sample, see Enable/Disable Codabar on page 4-39. A1234567890A NOTE To enable this symbology in order to scan the sample, see Enable/Disable MSI on page 4-42.
  • Page 145: Index

    Index discrete 2 of 5 ......4-37 lengths ......4-38 AIM code identifiers .
  • Page 146 Index - 2 Symbol CS3000 Series Scanner Product Reference Guide convert UPC-E to UPC-A ....4-17 host ........1-3 convert UPC-E1 to UPC-A .
  • Page 147 Symbol code identifiers ..... . . B-2 Motorola enterprise mobility support ....xiii symbology default parameters .
  • Page 148 Index - 4 Symbol CS3000 Series Scanner Product Reference Guide...
  • Page 150: Quick Start Instructions

    1-800-927-9626 http://www.motorola.com/enterprisemobility MOTOROLA and the Stylized M Logo and Symbol and the Symbol logo are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their respective owners. © Motorola, Inc. 2010...

Table of Contents