Sign In
Upload
Manuals
Brands
Dell Manuals
Storage
EMC VMAX 850F
User Manuals: Dell EMC VMAX 850F All Flash Storage
Manuals and User Guides for Dell EMC VMAX 850F All Flash Storage. We have
1
Dell EMC VMAX 850F All Flash Storage manual available for free PDF download: Site Planning Manual
Dell EMC VMAX 850F Site Planning Manual (132 pages)
All Flash. with Hypermax OS
Brand:
Dell
| Category:
Storage
| Size: 6.64 MB
Table of Contents
Table of Contents
3
Figures
7
Tables
9
Preface
11
Typographical Conventions Used in this Content
12
Revision History
14
Chapter 1 Pre-Planning Tasks
15
Before You Begin
16
Tasks to Review
16
VMAX All Flash Packaging
17
Chapter 2 Delivery and Transportation
19
Delivery Arrangements
20
Moving up and down Inclines
20
Pre-Delivery Considerations
20
Shipping and Storage Environmental Requirements
21
Specifications
23
CHAPTER 3 Specifications
24
Interference
24
Radio Frequency Interference
24
Recommended Minimum Distance from RF Emitting Device
24
Minimum Distance from RF Emitting Devices
24
Power Consumption and Heat Dissipation
25
Vmax 950F
25
Dissipation
25
Adaptive Cooling
26
Vmax 950F
26
Airflow
27
Typical Airflow in a Hot/Cold Aisle Environment
27
Airflow Diagram Key
27
Power Consumption and Heat
27
Air Volume, Air Quality, and Temperature
28
Air Volume Specifications
28
Temperature, Altitude, and Humidity Ranges
28
Temperature and Humidity Range Recommendations
28
Maximum Air Volume, VMAX 250F
28
Maximum Air Volume, VMAX 450F, VMAX 850F, VMAX 950F
28
Environmental Operating Ranges
28
Temperature
28
Air Quality Requirements
29
Temperature and Humidity
29
Shock and Vibration
30
Sound Power and Sound Pressure
30
Platform Shock and Vibration
30
Sound Power and Sound Pressure Levels, A-Weighted, VMAX 250F
30
Sound Power and Sound Pressure Levels, A-Weighted, VMAX 450F, VMAX 850F, VMAX 950F
30
Vibration
30
Pressure
30
Hardware Acclimation Times
31
Hardware Acclimation Times (Systems and Components)
31
Times
31
Optical Multimode Cables
32
Open Systems Host and SRDF Connectivity
32
OM3 and OM4 Fibre Cables - 50/125 Micron Optical Cable
32
Cables
32
Chapter 4 Data Center Safety and Remote Support
35
Fire Suppressant Disclaimer
36
Remote Support
36
Chapter 5 Physical Weight and Space
39
Floor Load-Bearing Capacity
40
Raised Floor Requirements
40
Physical Space and Weight
41
Space and Weight Requirements, VMAX 250F
41
Space and Weight Requirements, VMAX 450F, VMAX 850F, VMAX 950F
41
Chapter 6 Position VMAX 250F Bay
43
Bay Layout and Dimensions
44
Cabinet Dimensions and Clearances
44
Casters and Leveling Feet
45
Placement with Floor Tiles
45
Tile Placement
45
Cabinet Stabilizing
47
Chapter 7 Position VMAX 450F, VMAX 850F, VMAX 950F Bays
49
System Bay Layouts
50
Adjacent Layouts, VMAX 450F, VMAX 850F, VMAX 950F
51
Adjacent Layout, VMAX 450F, VMAX 850F, VMAX 950F
51
Adjacent Layout Diagram Key, VMAX 450F, VMAX 850F, VMAX 950F
51
Dispersed Layout, VMAX 450F, VMAX 850F, VMAX 950F
52
Dispersed Layout, Front View
52
Adjacent and Dispersed (Mixed) Layout
53
Adjacent and Dispersed (Mixed) Layout, Dual-Engine Array
53
Dimensions for Array Layouts
54
Layout Dimensions, VMAX 450F, VMAX 850F, VMAX 950F
54
Tile Placement
55
Placement with Floor Tiles, VMAX 450F, VMAX 850F, VMAX 950F
55
Caster and Leveler Dimensions
56
Caster and Leveler Dimensions Diagram Key
56
Chapter 8 Power Cabling, Cords and Connectors
59
Power Distribution Equipment, VMAX 250F
60
Power Distribution Unit (PDU), VMAX 250F, Rear View
61
Power Distribution Unit VMAX 450F, VMAX 850F, VMAX 950F
62
Power Distribution Unit (PDU) Without Installed Wire Bales, Rear View
63
Power Distribution Unit (PDU) with Installed Wire Bales, Rear View
63
Wiring Configurations, VMAX 250F
64
PDU Internal Wiring, VMAX 250F
64
Single-Phase, PDP Internal Wiring, VMAX 250F
65
Three-Phase (Delta), PDP Internal Wiring, VMAX 250F
66
Three-Phase (Wye), PDP Internal Wiring, VMAX 250F
67
Wiring Configurations, VMAX 450F, VMAX 850F, VMAX 950F
68
Single-Phase, Horizontal 2U PDU Internal Wiring, VMAX 450F, VMAX 850F, VMAX
69
Three-Phase (Delta), Horizontal 2U PDU Internal Wiring, VMAX 450F, VMAX 850F
70
Three-Phase (Wye), Horizontal 2U PDU Internal Wiring, VMAX 450F, VMAX 850F
71
Customer Input Power Cabling
72
VMAX 250F Customer AC Power Feed Cabling
73
Customer Input Power Cabling for VMAX 250F
73
Power Interface
72
Best Practices: Power Configuration Guidelines
74
Power Extension Cords, Connectors, and Wiring
74
Single-Phase
75
Extension Cords and Connectors Options - Single-Phase
75
Single-Phase: EF-PW40U-US (VMAX 450F, VMAX 850F), ET-PW40U-US (VMAX 950F), ES-PW40U-US (VMAX 250F)
77
Single-Phase: EF-PW40URUS (VMAX 450F, VMAX 850F), ET-PW40URUS (VMAX 950F), ES-PW40URUS (VMAX 250F)
78
Single-Phase: EF-PW40UIEC3 (VMAX 450F, VMAX 850F), ET-PW40UIEC3 (VMAX 950F), ES-PW40UIEC3 (VMAX 250F)
78
Single-Phase: EF-PW40UASTL (VMAX 450F, VMAX 850F), ET-PW40UASTL (VMAX 950F), ES-PW40UASTL (VMAX 250F)
79
Single-Phase: E-PW40L730
79
Three-Phase (International (Wye))
80
Extension Cords and Connectors Options - Three-Phase International (Wye)
80
Flying Leads, Three-Phase, International: EF-PC3YAFLE (VMAX 450F, VMAX 850F), ET-PC3YAFLE (VMAX 950F), ES-PC3YAFLE (VMAX 250F)
81
Three-Phase, International: EF-PCBL3YAG (VMAX 450F, VMAX 850F), ET- PCBL3YAG (VMAX 950F), ES-PCBL3YAG (VMAX 250F)
82
Three-Phase (North American (Delta))
83
Extension Cords and Connectors Options - Three-Phase North American (Delta)
83
Three-Phase, North American, Delta: EF-PCBL3DHR (VMAX 450F, VMAX 850F), ET- PCBL3DHR (VMAX 950F), ES-PCBL3DHR (VMAX 250F)
84
Three-Phase, North American, Delta: EF-PCBL3DHH (VMAX 450F, VMAX 850F), ET- PCBL3DHH (VMAX 950F), ES-PCBL3DHH (VMAX 250F)
84
Three-Phase (Wye, Domestic)
85
Extension Cords and Connectors Options - Three-Phase Wye, Domestic
85
Three-Phase, Domestic (Black and Gray): EF-PCBL3YL23P (VMAX 450F, VMAX 850F), ET-PCBL3YL23P (VMAX 950F), ES-PCBL3YL23P (VMAX 250F)
86
Chapter 9 EMC Racking for VMAX 250F
87
EMC Rack Requirements for Customer Components
88
Two System Configurations
88
Chapter 10 Third Party Racking Option for VMAX 250F
89
Computer Room Requirements, VMAX 250F
90
Customer Rack Requirements, VMAX 250F
90
PDU Requirements for Third Party Racks, VMAX 250F
91
Component Power Requirements, VMAX 250F
91
Engine and 2U SPS Power Requirements
92
Power Distribution Equipment for Third-Party Rack, VMAX 250F
94
Power Distribution Equipment C13 Outlet Connections Required for 1 V-Brick
94
Power Distribution Equipment C13 Outlet Connections Required for 2 V-Bricks
94
Chapter 11 Third Party Racking Option for VMAX 450F, VMAX 850F and VMAX 950F
95
Computer Room Requirements
96
Customer Rack Requirements
97
Customer Rack Dimension Requirements
98
Third Party Racks with Vertical Pdus - RPQ Required
99
Requirements for Third Party Racks with Vertical Pdus (Rear-Facing)
100
Requirements for Customer Rack with Rear-Facing, Vertical Pdus
100
Requirements for Third Party Racks with Vertical Pdus (Rear-Facing
101
Requirements for Third Party Racks with Vertical Pdus (Inward-Facing)
102
Requirements for Third Party Rack with Inward-Facing, Vertical Pdus
102
Chassis to Chassis Grounding
103
Chapter 12 Optional Kits
105
Optional Kits
105
Dispersion Kits, VMAX 450F, VMAX 850F
106
Overhead Routing Models, VMAX 250F
106
Overhead Routing Models, VMAX 450F, VMAX 850F, VMAX 950F
106
PDU/PDP Kits for VMAX 250F
106
Overhead Routing Kit
106
PDU/PDP Kits, VMAX 250F
106
Dispersion Kits, VMAX 950F
107
Dispersion Kit Model Numbers, VMAX 450F, VMAX 850F
107
Dispersion Kit Model Numbers, VMAX 950F
107
Gridrunner Kit and Customer-Supplied Cable Trough
108
Securing Kit Models, VMAX 250F
108
Securing Kit Models, VMAX 450F, VMAX 850F, VMAX 950F
108
Bottom Routing Model, VMAX 250F
109
Bottom Routing Model, VMAX 450F, VMAX 850F, VMAX 950F
109
Securing Kits
108
Best Practices for AC Power Connections
111
Best Practices for AC Power Connections Appendix A
112
Best Practices Overview for AC Power Connections
112
Two Independent Customer-Supplied Pdus
112
Selecting the Proper AC Power Connection Procedure
113
Procedure Options for AC Power Connection
113
Procedure A: Working with the Customer's Electrician Onsite
114
Procedure A, Task 1: Customer's Electrician
115
Circuit Breakers on - AC Power Within Specification
115
Circuit Breakers off - no AC Power
115
Procedure A, Task 2: EMC Customer Engineer
116
System Bay Power Tee Breakers (off = Pulled Out)
116
Connecting AC Power, Single-Phase
117
Connecting AC Power, Three-Phase
118
Power Zone Connections
119
Procedure A, Task 2: EMC Customer Engineer (VMAX 250F)
120
PDP Power Switches for Zone a and B
120
Connecting AC Power
121
Power Zone Connections
122
Customer Input Power Cabling for VMAX 250F
123
Procedure A, Task 3: Customer's Electrician
124
Procedure B: Verify and Connect
125
PDU Labels
126
PDU Label Part Numbers
126
VMAX 250F Label Part Numbers
126
VMAX 450F, VMAX 850F, VMAX 950F Label Part Numbers, EMC Racks
126
Applying PDU Labels, VMAX 250F
127
Applying the PDU Labels
127
Applying PDU Labels, VMAX 450F, VMAX 850F, VMAX 950F
128
Procedure C: Obtain Customer Verification
126
Ground the Cabinet
128
PDU Label , Single-Phase and Three-Phase
128
Label Placement- Customer PDU Information
128
Location of Cabinet Ground Lugs
129
AC Power Specifications
130
Input Power Requirements - Single-Phase, North American, International, Australian
130
Input Power Requirements - Three-Phase, North American, International, Australian
131
Advertisement
Advertisement
Related Products
Dell EMC Unity 880/F
Dell EMC VMAX 250F
Dell EMC VMAX 450F
Dell EMC VMAX 950F
Dell PowerEdge 850
Dell Inspiron 8500
Dell 85HD7
Dell Inspiron 8200
Dell Precision 8F765
Dell PowerEdge 800
Dell Categories
Laptop
Desktop
Server
Monitor
Storage
More Dell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL