Table of Contents
3
Additional Resources
8
Chapter 1: Install a New Base Enclosure and Optional Expansion Enclosure
9
Install a New Base Enclosure
9
Installation Power Overview
9
Choose Where to Install the Base Enclosure
10
Unpack the Base Enclosure
10
Install the Rails in the Cabinet
10
Install the Base Enclosure on the Rails
11
Cable the Base Enclosure Appliance to Switches
12
Connect Power Cables
12
Discover Your System
12
Upgrade Powerstore Software
13
Install an Nvme Expansion Enclosure
13
Summary of Tasks for Installing an Expansion Enclosure
13
Verify Shipping Package Contents
13
Choose Where to Install the Expansion Enclosure
15
Removing a Filler Panel
15
Installing the Nvme Expansion Enclosure Rails
15
Install the System in the Cabinet
17
Installing Cable Management Arms
19
Cable the Base Enclosure to the Nvme Expansion Enclosure
20
Closing the Cable Management Arms
22
Testing the Cable Management Arms
23
Installing Drives
23
Installing the Front Bezel
24
Add an Nvme Expansion Enclosure
25
Summary of Tasks for Adding an Expansion Enclosure
25
Verify Shipping Package Contents
25
Choose Where to Install the Expansion Enclosure
27
Removing a Filler Panel
27
Installing the Nvme Expansion Enclosure Rails
27
Install the System in the Cabinet
29
Installing Cable Management Arms
31
Cable the New Nvme Expansion Enclosure
32
Closing the Cable Management Arms
34
Testing the Cable Management Arms
35
Installing Drives
35
Installing the Front Bezel
36
Chapter 2: Base Enclosure Service Procedures
38
Replace a Faulted Drive in the Base Enclosure
38
Identify a Faulted Drive from Powerstore Manager
38
Remove a Faulted 2.5" Drive
38
Install a 2.5" Drive
39
Verify the Operation of a Replacement Drive
40
Return a Faulted Part
40
Add a New Drive to the Base Enclosure
40
Removing the Front Bezel
40
Remove a Drive Filler Module
40
Install a 2.5" Drive
41
Verify the Operation of an Added Drive
42
Replace an AC Power Supply
42
Identify a Faulted Power Supply from Powerstore Manager
42
Base Enclosure AC Power Supply
43
Remove a Power Supply
43
Install a Power Supply
44
Verify the Operation of a Replacement Power Supply
45
Return a Faulted Part
45
Replace a DC Power Supply
45
Identify a Faulted Power Supply from Powerstore Manager
46
Base Enclosure DC Power Supply
46
Remove a DC Power Supply
46
Install a DC Power Supply
47
Verify the Operation of a Replacement Power Supply
48
Return a Faulted Part
48
Replace a 4-Port Card
49
Before You Begin
49
Identify a Faulted 4-Port Card from Powerstore Manager
49
Embedded Module Leds
49
Power down the Node
50
Remove the Node
50
Remove the Embedded Module Cover from the Node
52
Remove a 4-Port Card
53
Install a 4-Port Card
54
Install the Embedded Module Cover
55
Install the Node
56
Power up the Node
56
Verify the Operation of a New 4-Port Card
57
Return a Faulted Part
57
Replace an SFP
57
Identify a Faulted SFP Module from Powerstore Manager
57
Remove an SFP Module
58
Install an SFP Module
58
Verify the Operation of a Replacement SFP Module
58
Return a Faulted Part
59
Replace an I/O Module
59
Before You Begin
59
Identify a Faulted I/O Module from Powerstore Manager
59
Base Enclosure I/O Module Leds
60
Power down the Node
60
Remove an I/O Module
60
Install an I/O Module
61
Power up the Node
61
Verify the Operation of a Replacement I/O Module
62
Return a Faulted Part
62
Replace a Fan Module
62
Before You Begin
62
Identify a Faulted Fan Module from Powerstore Manager
62
Power down the Node
63
Remove the Node
63
Remove the Top Cover from the Node
64
Remove the Fan Module
65
Install the Fan Module
66
Install the Top Cover on the Node
66
Install the Node
67
Verify the Operation of a Replacement Fan Module
68
Return a Faulted Part
68
Replace a Dual Inline Memory Module (DIMM)
69
Before You Begin
69
Identify a Faulted DIMM from Powerstore Manager
69
Power down the Node
69
Remove the Node
69
Remove the Top Cover from the Node
71
Remove the Dual Inline Memory Module
72
Install the Dual Inline Memory Module
72
Install the Top Cover on the Node
73
Install the Node
74
Verify the Operation of a Replacement DIMM
74
Return a Faulted Part
75
Replace an Internal M.2 Boot Module
75
Before You Begin
75
Identify a Faulted Internal M.2 Boot Module from Powerstore Manager
75
Establish Connectivity to the Peer Node Via SSH
76
Power down the Node
76
Remove the Node
76
Remove the Top Cover from the Node
78
Remove the Internal M.2 Boot Module
78
Install the Internal M.2 Boot Module
79
Install the Top Cover on the Node
80
Install the Node
80
Reimage the New Internal M.2 Boot Module
81
Verify the Operation of a Replacement Internal M.2 Boot Module
82
Return a Faulted Part
83
Chapter 3: Nvme Expansion Enclosure Service Procedures
84
Replace a Faulted Drive in an Nvme Expansion Enclosure
84
Identify a Faulted Drive from Powerstore Manager
84
Removing the Front Bezel
84
Remove a Faulted Drive
85
Installing a Drive
85
Installing the Front Bezel
86
Verify the Operation of a Replacement Drive
87
Return a Faulted Part
87
Add a Drive in an Nvme Expansion Enclosure
87
Removing the Front Bezel
87
Remove a Drive Filler Module
88
Installing a Drive
89
Installing the Front Bezel
89
Verify the Operation of an Added Drive
90
Replace a Power Supply Module in an Nvme Expansion Enclosure
90
Identify a Faulted Power Supply from Powerstore Manager
90
Nvme Expansion Enclosure Power Supply Leds
91
Remove a Power Supply
91
Install a Power Supply
92
Verify the Operation of a Replacement Power Supply
93
Return a Faulted Part
93
Replace a Fan Module in an Nvme Expansion Enclosure
94
Identify a Faulted Fan Module from Powerstore Manager
94
Remove a Fan Module
94
Install a Fan Module
96
Verify the Operation of a Replacement Fan Module
98
Return a Faulted Part
98
Replace a Clock Distribution Board in an Nvme Expansion Enclosure
99
Identify a Faulted Clock Distribution Board from Powerstore Manager
99
Remove a Clock Distribution Board
99
Install a Clock Distribution Board
101
Verify the Operation of a Replacement Clock Distribution Board
103
Return a Faulted Part
103
Replace an Access Module in an Nvme Expansion Enclosure
104
Identify a Faulted Access Module from Powerstore Manager
104
Remove an Access Module
104
Install an Access Module
105
Verify the Operation of a Replacement Access Module
106
Return a Faulted Part
106
Replace a Data Interface Board in an Nvme Expansion Enclosure
107
Identify a Faulted DIB from Powerstore Manager
107
Removing a DIB
107
Replacing a DIB
108
Verify the Operation of a Replacement DIB
109
Return a Faulted Part
109
Appendix A: Safety Precautions for Handling Replaceable Units
111
Handling Replaceable Units
111
Avoiding Electrostatic Discharge (ESD) Damage
111
Emergency Procedures (Without an Electrostatic Discharge Kit)
111
Hardware Acclimation Times
112
Removing, Installing, or Storing Replaceable Units
112
Unpacking a Part
113
Appendix B: Power Control Procedures
114
Power Control Procedure Considerations
114
Powering off Procedures for Powerstore Node
114
Power off a Powerstore T Model Node Using Powerstore Manager
115
Power off a Powerstore T Model Node Using a Service Script
115
Powering on Procedures for Powerstore Node
116
Power on a Powerstore T Model Node Using a Service Script
116
Power on a Powerstore T Model Node by Reseating the Node
116
Rebooting Procedures for a Powerstore Node
117
Reboot a Powerstore T Model Node Using Powerstore Manager
117
Reboot a Powerstore T Model Node Using a Service Script
117
Powering off Procedures for Powerstore Appliances
118
Power off a Powerstore T Model Appliance
118
Powering on Procedures for Powerstore Appliances
119
Power on a Powerstore T Model Appliance
119
Powering off Procedures for Powerstore Cluster
119
Power off a Powerstore T Model Cluster
119
Powering on Procedures for Powerstore Cluster
120
Power on a Powerstore T Model Cluster
120
Appendix C: Data Collection
121
Support Materials Collection
121
Collect Support Materials
121
Appendix D: Support Notifications
123
Disable Support Notifications
123
Enable Support Notifications
123
Appendix E: Add Appliances to the Cluster
124
Add Appliances to the Cluster
124
Appendix F: Remove Appliances from the Cluster
125
Removing an Appliance from a Powerstore Cluster
125
Remove an Appliance from a Powerstore T Model Cluster
125
Remove an Appliance from a Powerstore X Model Cluster
126
Migrate Storage Objects from an Appliance
129
Appendix G: Reinitialize the System
131
Reinitialize the System
131
Advertisement
Dell PowerStore 500T Installation And Service Manual (66 pages)
Brand:
Dell
| Category:
Storage
| Size: 6.65 MB
Table of Contents
Table of Contents
3
Additional Resources
6
Chapter 1: Install a New Base Enclosure
7
Install a New Base Enclosure
7
Choose Where to Install the Base Enclosure
7
Unpack the Base Enclosure
7
Install the Rails in the Cabinet
8
Install the Base Enclosure on the Rails
8
Cable the Base Enclosure Appliance to Switches
9
Connect Power Cables
9
Discover Your System
10
Upgrade Powerstore Software
10
Chapter 2: Base Enclosure Service Procedures
11
Replace a Faulted Drive in the Base Enclosure
11
Identify a Faulted Drive from Powerstore Manager
11
Remove a Faulted 2.5" Drive
11
Install a 2.5" Drive
12
Verify the Operation of a Replacement Drive
13
Return a Faulted Part
13
Add a New Drive to the Base Enclosure
13
Removing the Front Bezel
13
Remove a Drive Filler Module
13
Install a 2.5" Drive
14
Verify the Operation of an Added Drive
15
Replace a Power Supply
15
Identify a Faulted Power Supply from Powerstore Manager
15
Base Enclosure Power Supply Leds
16
Remove a Power Supply
16
Install a Power Supply
17
Verify the Operation of a Replacement Power Supply
18
Return a Faulted Part
18
Replace a 4-Port Card
18
Before You Begin
18
Identify a Faulted 4-Port Card from Powerstore Manager
19
Embedded Module Leds
19
Power down the Node
20
Remove the Node
20
Remove the Embedded Module Cover from the Node
22
Remove a 4-Port Card
22
Install a 4-Port Card
23
Install the Embedded Module Cover
24
Install the Node
25
Power up the Node
26
Verify the Operation of a New 4-Port Card
26
Return a Faulted Part
26
Replace an SFP
27
Identify a Faulted SFP Module from Powerstore Manager
27
Remove an SFP Module
27
Install an SFP Module
27
Verify the Operation of a Replacement SFP Module
28
Return a Faulted Part
28
Replace an I/O Module
28
Before You Begin
29
Identify a Faulted I/O Module from Powerstore Manager
29
Base Enclosure I/O Module Leds
29
Power down the Node
29
Remove a Faulted I/O Module
30
Install a New I/O Module
30
Power up the Node
31
Verify the Operation of a Replacement I/O Module
31
Return a Faulted Part
31
Replace a Fan Module
31
Before You Begin
32
Identify a Faulted Fan Module from Powerstore Manager
32
Power down the Node
32
Remove the Node
32
Remove the Top Cover from the Node
34
Remove the Faulted Fan Module
34
Install a New Fan Module
35
Install the Top Cover on the Node
36
Install the Node
37
Power up the Node
37
Verify the Operation of a Replacement Fan Module
38
Return a Faulted Part
38
Replace a Dual Inline Memory Module (DIMM)
38
Before You Begin
38
Identify a Faulted DIMM from Powerstore Manager
38
Power down the Node
39
Remove the Node
39
Remove the Top Cover from the Node
40
Remove the Faulted Dual Inline Memory Module
41
Install the Dual Inline Memory Module
42
Install the Top Cover on the Node
42
Install the Node
43
Power up the Node
44
Verify the Operation of a Replacement DIMM
44
Return a Faulted Part
44
Replace an Internal M.2 Boot Module
45
Before You Begin
45
Identify a Faulted Internal M.2 Boot Module from Powerstore Manager
45
Establish Connectivity to the Peer Node Via SSH
45
Power down the Node
45
Remove the Node
46
Remove the Top Cover from the Node
47
Remove the Faulted Internal M.2 Boot Module
48
Install the Internal M.2 Boot Module
49
Install the Top Cover on the Node
49
Install the Node
50
Power up the Node
51
Reimage the New Internal M.2 Boot Module
51
Verify the Operation of a Replacement Internal M.2 Boot Module
52
Return a Faulted Part
52
Appendix A: Safety Precautions for Handling Replaceable Units
53
Handling Replaceable Units
53
Avoiding Electrostatic Discharge (ESD) Damage
53
Emergency Procedures (Without an Electrostatic Discharge Kit)
53
Hardware Acclimation Times
54
Removing, Installing, or Storing Replaceable Units
54
Unpacking a Part
55
Appendix B: Power Control Procedures
56
Power Control Procedure Considerations
56
Powering off Procedures for Powerstore Node
56
Power off a Powerstore T Model Node Using Powerstore Manager
57
Power off a Powerstore T Model Node Using a Service Script
57
Powering on Procedures for Powerstore Node
58
Power on a Powerstore T Model Node Using a Service Script
58
Power on a Powerstore T Model Node by Reseating the Node
58
Rebooting Procedures for a Powerstore Node
59
Reboot a Powerstore T Model Node Using Powerstore Manager
59
Reboot a Powerstore T Model Node Using a Service Script
59
Powering off Procedures for Powerstore Appliances
60
Power off a Powerstore T Model Appliance
60
Powering on Procedures for Powerstore Appliances
60
Power on a Powerstore T Model Appliance
61
Powering off Procedures for Powerstore Cluster
61
Power off a Powerstore T Model Cluster
61
Powering on Procedures for Powerstore Cluster
62
Power on a Powerstore T Model Cluster
62
Appendix C: Data Collection
63
Support Materials Collection
63
Collect Support Materials
63
Appendix D: Support Notifications
65
Disable Support Notifications
65
Enable Support Notifications
65
Appendix E: Reinitialize the System
66
Reinitialize the System
66
Advertisement
Related Products
Dell Axim 500GB Portable External Hard Drive USB 3.0
Dell PowerStore 520
Dell PowerStore 1000
Dell PowerStore 1200
Dell PowerStore 3000
Dell PowerStore 3200
Dell PowerStore 7000
Dell Vostro 500
Dell 500W
Dell OptiPlex 5000 Micro
Dell Categories
Laptop
Desktop
Server
Monitor
Storage
More Dell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL