Lenovo DE120S Hardware Installation And Maintenance Manual (293 pages)
for 2U Enclosures
Brand:
Lenovo
| Category:
Enclosure
| Size: 8.94 MB
Table of Contents
Table of Contents
3
Safety
5
Chapter 1. Introduction
7
DE Series Hardware Overview
7
Front View
8
Front View of Models with 12 Drive Bays
8
Front View of Models with 24 Drive Bays
8
Rear View of DE2000 Series
9
Rear View of DE4000 Series
10
Rear View of DE120S and DE240S
11
Rear View of DE6000 Series
11
Specifications of DE2000 Series
12
Specifications of DE2000H (24 Drives)
14
Specifications of DE4000 Series
16
Specifications of DE4000H or DE4000F (24 Drives)
18
Specifications of DE6000 Series
20
Specifications of DE6000F (24 Drives)
22
Specifications of Drive Shelves
24
Specifications of DE240S
26
Management Software Overview
27
Thinksystem System Manager
27
Thinksystem SAN Manager
28
Thinksystem Storage Manager
28
Chapter 2. System Setup and Configuration
29
Initial Setup
29
Install Hardware
29
Cabling Your Storage System
30
Overview and Requirements
30
Applicable Hardware Models
30
Host Cabling
31
Cabling for a Direct-Attached Topology
31
Required Components
31
Cabling for a Switch Topology
31
Two Hosts and Two Switches
32
Drive Shelf Cabling
32
Cabling a 12-Drive or 24-Drive Shelf
32
Power Cabling
33
Hot Adding a Drive Shelf
33
Prepare to Add the Drive Shelf
33
A Controller Shelf and 12-Drive or 24-Drive Shelves
33
Install the Drive Shelf and Apply Power
34
Connect the Drive Shelf
35
Complete Hot Add
36
Ethernet Cabling for a Management Station
37
Direct Topology
37
Direct Storage Management Connections
37
Switch Topology
37
Switch Storage Management Connections
38
Windows Express Configuration
38
Decide Whether to Use this Express Method
38
Understand the Workflow
40
Verify the Windows Configuration Is Supported
40
Configure Management Port IP Addresses
41
Configure the Multipath Software
41
Access Thinksystem System Manager and Use the Setup Wizard
42
Install Thinksystem Storage Manager for Smcli and Host Context Agent (HCA)
42
Perform FC-Specific Tasks
44
Configuring the FC Switches - Windows
44
Determining Host Wwpns and Making the Recommended Settings - FC, Windows
44
FC Worksheet for Windows
45
Perform Iscsi-Specific Tasks
46
Configuring the Switches - Iscsi, Windows
46
Mapping Host
46
Configuring Networking - Iscsi Windows
46
Configuring Host-Side Networking—Iscsi
48
Verifying IP Network Connections - Iscsi, Windows
50
Recording Iscsi-Specific Information for Windows
51
Recommended Configuration
51
Perform SAS-Specific Tasks
51
Determining SAS Host Identifiers - Windows
52
Recording SAS-Specific Information for Windows
53
Discover Storage on the Host
53
Configure Storage on the Host
54
Verify Storage Access on the Host
54
Vmware Express Configuration
55
Deciding Whether to Use this Express Method
55
Verify the Vmware Configuration Is Supported
57
Understand the Workflow
57
Configure Management Port IP Addresses
58
Configure the Multipath Software
58
Install Thinksystem Storage Manager for Smcli and Host Context Agent (HCA)
58
Access Thinksystem System Manager and Use the Setup Wizard
58
Configuring the FC Switches - Vmware
60
Determining the Host Port Wwpns—Fc
60
Perform FC-Specific Tasks
60
FC Worksheet for Vmware
61
Configuring the Switches - Iscsi, Vmware
62
Configuring Networking - Iscsi Vmware
62
Perform Iscsi-Specific Tasks
62
Configuring Array-Side Networking - Iscsi, Vmware
63
Verifying IP Network Connections - Iscsi, Vmware
65
Recording Iscsi-Specific Information for Vmware
67
Iscsi Worksheet - Vmware
67
Perform SAS-Specific Tasks
67
Determining SAS Host Identifiers - Vmware
68
Recording SAS-Specific Information for Vmware
69
Discover Storage on the Host
69
Linux Express Configuration
70
Configure Storage on the Host
70
Verify Storage Access on the Host
70
Decide Whether to Use this Express Method
70
Fibre Channel Express Setup
71
Verify the Linux Configuration Is Supported
71
Record FC-Specifc Information for Linux
78
SAS Express Setup
79
Determine SAS Host Identifiers - Linux
82
Create Partitions and Filesystems
82
Record SAS-Specific Information for Linux
84
Iscsi Express Setup
85
Configure Array-Side Networking
89
Configure Host-Side Networking
91
Verify IP Network Connections
92
Record Iscsi-Specific Information for Linux
95
Batteries
97
Battery Overview
97
Chapter 3. Hardware Replacement Procedures
97
Overview and Requirements
97
Replace Battery
98
Prepare to Replace Battery
98
Place Controller Offline
98
Remove Failed Battery
99
Install New Battery
102
Complete Battery Replacement
104
Place Controller Online
104
Requirements for Replacing a Failed Battery
97
Controller Overview
106
Controllers
106
Overview and Requirements
106
Requirements for Replacing Controller
106
Prepare to Replace Controller
107
Replace a Controller
107
Install New Controller
113
Complete Controller Replacement
117
Overview and Requirements
118
Power Supply Overview
118
Prepare to Replace Power Supply
119
Replace Power Supply (12-Drive or 24-Drive)
119
Requirements for Replacing a Power Supply
119
Remove Failed Power Supply
120
Install New Power Supply
121
Complete Power Supply Replacement
122
Power-Fan Canisters
118
Drives
122
Overview and Requirements
122
12-Drive or 24-Drive Shelves
123
Drive Numbering in a 12-Drive Controller Shelf or Drive Shelf
123
Drive Numbering in a 24-Drive Controller Shelf or Drive Shelf
123
Requirements for Handling Drives
123
Prepare to Replace Drive (12-Drive or 24-Drive)
124
Remove Failed Drive (12-Drive or 24-Drive)
124
Replace Drive (12-Drive or 24-Drive)
124
Install New Drive (12-Drive or 24-Drive)
125
Complete Drive Replacement (12-Drive or 24-Drive)
126
Host Interface Card Overview
126
Overview and Requirements
126
Add HIC
127
Upgrade HIC
127
Replace HIC
128
Requirements for Adding, Upgrading or Replacing a HIC
128
Add Host Interface Cards
129
Prepare to Add Host Interface Cards
129
Add Host Interface Card
130
Complete Adding a Host Interface Card
134
Prepare to Upgrade Host Interface Cards
136
Upgrade Host Interface Card
136
Remove Controller Canister
138
Complete Host Interface Card Upgrade
143
Replace Host Interface Card
144
Prepare to Replace Host Interface Card
145
Complete Host Interface Card Replacement
150
Host Interface Cards
126
Host Port Protocol
152
Overview and Requirements
152
Host Protocol Overview
153
Which Host Ports Can You Change
153
Requirements for Changing the Host Protocol
153
Considerations for Changing the Host Protocol
154
Converting from FC to Iscsi
154
Converting from Iscsi to FC
154
Converting from FC to Fc/Iscsi
154
Data Assurance Considerations
155
Converting from Iscsi to Fc/Iscsi
156
Converting from Fc/Iscsi to FC
156
Converting from Fc/Iscsi to Iscsi
157
Same Host Protocol and Mirroring Operations
157
Change Host Protocol
157
Determine Whether You Have Dual-Protocol Sfps
157
Obtain the Feature Pack
158
Stop Host I/O
162
Change the Feature Pack
163
Complete Host Protocol Conversion
163
Complete FC to Iscsi Conversion
163
Complete Iscsi to FC Conversion
164
Complete FC to Fc/Iscsi Conversion
165
Complete Iscsi to Fc/Iscsi Conversion
166
Complete Fc/Iscsi to FC Conversion
167
Overview and Upgrade Considerations
169
Considerations for Upgrading Controller Software and Firmware
169
Chapter 4. System Upgrade
169
Upgrade Thinksystem SAN os Software
169
Considerations for Upgrading Drive Firmware
170
Drive Compatibility
170
Pre-Upgrade Health Check
170
When to Stop I/O
170
Upgrade Controller Software and Firmware Workflow
171
Download Software Files from Support Site
172
Transfer Software Files to the Controllers
172
Upgrade Controller Software and Firmware
172
Upgrade Drive Firmware Workflow
172
Activate Software Files
173
Complete Software and Firmware Upgrade
173
Download Drive Firmware Files from Support Site
175
Upgrade Drive Firmware
175
Begin Drive Firmware Upgrade
176
Workflows for Upgrading Software and Firmware
171
Chapter 5. System Monitoring
179
Leds on the Rear of Controllers
180
DE6000 Controller with Quad-Port HIC
180
DE4000 Controller with Quad-Port HIC
180
DE2000 Controller with Dual-Port HIC
180
Leds on the Operator Display Panel
182
Setting the Shelf ID with the ODP Push Button
183
ODP Push Button on Controller Shelf and Drive Shelf with 12 Drives
183
ODP Push Button on Controller Shelf and Drive Shelf with 24 Drives
183
Leds on the 2.5-Inch Drives
185
Leds on the 3.5-Inch Drives
185
Leds on the Ioms
186
Leds on the Power-Fan Canister
187
Seven-Segment Display Overview
188
Seven-Segment Display Sequence Codes
188
Seven-Segment Display Codes When Controller Turns on
189
Seven-Segment Display Use Cases
190
Seven-Segment Display Lock-Down Codes
191
Understanding the Controller Leds and Displays
179
Critical Events Reference
192
Storage Array Alert Traps
192
Critical Event Data
193
MEL_EV_DRIVE_PFA - 0X1010
193
MEL_EV_SYNTH_DRIVE_PFA - 0X101E
193
MEL_EV_FC_LINK_ERROR_THRESHOLD_CRITICAL - 0X1207
194
MEL_EV_FC_SPEED_NEG_FAILURE - 0X1208
194
MEL_EV_PI_DRIVE_LOCKED_OUT - 0X1020
194
MEL_EV_DEGRADE_CHANNEL - 0X1209
195
MEL_EV_FC_SFP_FAILED - 0X120A
195
MEL_EV_DFC_ALT_LOOP_DIAG_FAIL - 0X150E
196
MEL_EV_EXCESSIVE_REBOOTS_DETECTED - 0X1403
196
MEL_EV_FC_HOST_SFP_FAILED - 0X120D
196
MEL_EV_DFC_CHANNEL_MISWIRE - 0X150F
197
MEL_EV_DFC_ESM_MISWIRE - 0X1510
197
MEL_EV_DFC_CHANNEL_FAILOVER - 0X1513
198
MEL_EV_DFC_HW_FAILED_CHANNEL - 0X1515
198
MEL_EV_DFC_LSD_FAILURE - 0X151A
198
MEL_EV_DFC_CTL_MISWIRE - 0X151E
199
MEL_EV_DFC_MIXED_LOOP_TECHNOLOGY_MISWIRE - 0X1522
199
MEL_EV_DFC_FIBRE_TRUNK_MISWIRE - 0X1525
200
MEL_EV_DFC_TRUNK_INCOMPATIBLE_ESM - 0X1524
200
MEL_EV_SAS_FRNT_END_MISWIRE - 0X1650
200
MEL_EV_SAS_HOST_WIDE_PORT_DEGRADED - 0X1654
201
MEL_EV_SAS_PARTNER_INITIATOR_OVERFLOW - 0X1652
201
MEL_EV_DSAS_TOPOLOGY_MISWIRE - 0X1700
202
MEL_EV_SAS_BACKEND_DISCOVERY_ERROR - 0X165A
202
MEL_EV_DSAS_BK_END_HBA_MISWIRE - 0X1702
203
MEL_EV_DSAS_ESM_MISWIRE - 0X1704
203
MEL_EV_DSAS_WPORT_OPT_TO_DEG - 0X1706
203
MEL_EV_DSAS_EXP_PORT_DEV_MISWIRE - 0X170A
204
MEL_EV_DSAS_WPORT_DEG_TO_FAIL - 0X1707
204
MEL_EV_DSAS_WPORT_DEG_TO_FAIL_CTLR - 0X1710
205
MEL_EV_DSAS_WPORT_OPT_TO_DEG_CTLR - 0X170F
205
MEL_EV_LOSS_EXT_REDUNDANCY - 0X171A
205
MEL_EV_FAILED_HOST_INTERFACE_CARD - 0X1904
206
MEL_EV_ISCSI_FAILED_HOST_CARD - 0X180A
206
MEL_EV_DATA_PARITY_MISMATCH - 0X200A
207
MEL_EV_HIC_CONFIGURATION_OOC - 0X1908
207
MEL_EV_MISSING_DRIVE_LOCKDOWN - 0X1907
207
MEL_EV_DRIVE_FAIL_READ_ERROR_SCAN_CYCLE - 0X203B
208
MEL_EV_MISCORRECTED_DATA - 0X202E
208
MEL_EV_ISOLATION_REDUN_MISMATCH - 0X2046
209
MEL_EV_REDUN_GROUP_NOT_CONSISTENT - 0X2045
209
MEL_EV_DATA_ALTERED_TO_CORRECT_REDUN_MISMATCH - 0X2048
210
MEL_EV_DIFFERENT_DATA_RETURNED_ON_RETRY - 0X2047
210
MEL_EV_PI_SERVICE_MODE_ENTERED - 0X2069
210
MEL_EV_CCM_HW_MISMATCH - 0X2109
211
MEL_EV_PI_ANALYSIS_LOCKDOWN_MODE_ENTERED - 0X206A
211
MEL_EV_CACHE_BATTERY_FAILURE - 0X210C
212
MEL_EV_CACHE_DATA_LOSS - 0X210E
212
MEL_EV_CACHE_MEM_DIAG_FAIL - 0X2110
213
MEL_EV_CACHE_BACKUP_INSUFFICIENT_CAPACITY - 0X211F
214
MEL_EV_UNSUPPORTED_CACHE_SIZE - 0X211E
214
MEL_EV_CACHE_BACKUP_PROTECTION_ERROR - 0X2125
215
MEL_EV_DEDICATED_MIRROR_CHANNEL_FAILED - 0X2124
215
MEL_EV_INSUFFICIENT_MEMORY_FOR_CACHE_SIZE - 0X2120
215
MEL_EV_INCOMPLETE_CACHE_BACKUP - 0X2126
216
MEL_EV_WB_CACHING_FORCIBLY_DISABLED - 0X212B
216
MEL_EV_CACHE_NOT_FLUSHED_ON_ONLY_CTLR - 0X2131
217
MEL_EV_DEVICE_FAIL - 0X222D
217
MEL_EV_RCB_CACHE_DATA_LOSS - 0X212E
217
MEL_EV_CFG_DRV_TO_SMALL - 0X2249
218
MEL_EV_WRONG_SECTOR_SIZE - 0X224A
218
MEL_EV_DRV_FORMAT_FAILED - 0X224B
219
MEL_EV_DRV_NO_RESPONSE - 0X224D
219
MEL_EV_RECON_DRV_FAILED - 0X224E
219
MEL_EV_CFG_READ_FAIL - 0X2251
220
MEL_EV_LUN_DOWN - 0X2250
220
MEL_EV_FAIL_VDSK_DELAYED - 0X2252
221
MEL_EV_UNCERTIFIED_DRIVE - 0X2260
221
MEL_EV_CFG_WRONG_DRIVE_TYPE - 0X2262
222
MEL_EV_INCOMPAT_DRIVE_INVALID_CONFIG - 0X2267
222
MEL_EV_RECONFIGURATION_FAILED - 0X2266
222
MEL_EV_CFG_DRIVE_FAILURE - 0X226C
223
MEL_EV_FDE_LOCK_KEY_NEEDED - 0X226B
223
MEL_EV_DRIVE_IN_VG_OR_HOT_SPARE_REMOVED - 0X226D
224
MEL_EV_SSD_AT_END_OF_LIFE - 0X226E
224
MEL_EV_DRIVE_UNSUPPORTED_CAPACITY - 0X2271
225
MEL_EV_HOT_SPARE_IN_USE - 0X2273
225
MEL_EV_VOLUME_GROUP_MISSING - 0X2274
225
MEL_EV_DRIVE_UNSUP_INTERPOSER_FW_VER - 0X2276
226
MEL_EV_VOLUME_GROUP_INCOMPLETE - 0X2275
226
MEL_EV_COPY_THEN_FAIL_NO_SPARE - 0X227C
227
MEL_EV_INCOMPATIBLE_ALIGNMENT_FOR_EMULATION_DRIVE - 0X2278
227
MEL_EV_CFG_NTP_RES - 0X2287
228
MEL_EV_CFG_NTP_UNREACH - 0X2288
228
MEL_EV_DRIVE_PFA2 - 0X2285
228
MEL_EV_CFG_NTP_SERVICE_UNAVAIL - 0X2289
229
MEL_EV_SBB_VALIDATION_FAIL_FOR_POWER_SUPPLY - 0X2302
229
MEL_EV_SBB_MISMATCHED_ENCL_EEPROM_CONTENTS - 0X2303
230
MEL_EV_SBB_TWO_WIRE_INTERFACE_BUS_FAILURE - 0X2304
230
MEL_EV_SBB_VPD_EEPROM_CORRUPTION - 0X2305
230
MEL_EV_ACS_ERROR - 0X2602
231
MEL_EV_CONTROLLER - 0X2500
231
MEL_EV_MULTIPLE_MISMATCHED_KEY_IDS - 0X2705
232
MEL_EV_PERSIST_MPE - 0X2604
232
MEL_EV_SOD_FDE_INCONSISTENT_ARRAY_LOCK_KEY - 0X2607
232
MEL_EV_ON_BATTERY - 0X2801
233
MEL_EV_UPS_BATTERY_2MIN - 0X2803
233
MEL_EV_ENCL_FAIL - 0X280D
234
MEL_EV_LINE_FAILED - 0X280B
234
MEL_EV_LINE_MISSING - 0X280A
234
MEL_EV_ENCL_ID_CONFLICT - 0X2816
235
MEL_EV_TEMP_SENSOR_WARNING - 0X281B
235
MEL_EV_ESM_VERSION_MISMATCH - 0X281E
236
MEL_EV_TEMP_SENSOR_FAIL - 0X281C
236
MEL_EV_TEMP_SENSOR_MISSING - 0X281D
236
MEL_EV_BYPASS_GENERIC - 0X2823
237
MEL_EV_CONT_REDUNDANCY_LOSS - 0X2829
237
MEL_EV_DRIVE_REDUNDANCY_LOSS - 0X282D
238
MEL_EV_TRAY_REDUNDANCY_LOSS - 0X282B
238
MEL_EV_MIXED_DRIVE_TYPES_NOT_ALLOWED - 0X2830
239
MEL_EV_UNCERTIFIED_ESM - 0X2831
239
MEL_EV_UNSUPPORTED_LHA_SATA_ESM - 0X282F
239
MEL_EV_CONT_ID_MISMATCH - 0X2833
240
MEL_EV_DRIVE_TRAY_LOCKOUT - 0X2832
240
MEL_EV_DISCRETE_LINE_FAIL - 0X2836
241
MEL_EV_DRIVE_TRAYS_NOT_GROUPED_TOGETHER - 0X2835
241
MEL_EV_ICC_REMOVED - 0X2838
241
MEL_EV_CONT_SUBMODEL_MISMATCH - 0X2841
242
MEL_EV_POWER_SUPPLY_FAIL - 0X283B
242
MEL_EV_ESM_TYPE_MISMATCH - 0X2849
243
MEL_EV_LINK_SPEED_SWITCH_CHANGE - 0X284B
243
MEL_EV_REDUNDANT_PS_REQUIRED - 0X284E
243
MEL_EV_FACTORY_DEFAULT_MISMATCH - 0X2852
244
MEL_EV_INVALID_ENCLOSURE_SETTING - 0X284F
244
MEL_EV_CONT_ID_READ_FAILURE - 0X2855
245
MEL_EV_ESM_DRIVE_BYPASS - 0X2854
245
MEL_EV_DRAWER_FAILED - 0X2856
246
MEL_EV_DRAWER_OPEN - 0X2857
246
MEL_EV_EXPANSION_TRAY_THERMAL_SHUTDOWN - 0X285D
246
MEL_EV_DRAWER_DEGRADED - 0X285F
247
MEL_EV_DRAWER_INVALID - 0X2861
247
MEL_EV_DRAWER_REMOVED - 0X2862
248
MEL_EV_HOST_SFP_FAILED - 0X2863
248
MEL_EV_HOST_SFP_UNSUPPORTED - 0X2864
248
MEL_EV_FLASH_CACHE_FAILED_CACHE_SIZE_MISMATCH - 0X3604
249
MEL_EV_ICM_ENTERING_INVALID_SYSTEM_CONFIG - 0X2900
249
MEL_EV_DISK_POOL_REC_RDRVCNT_BEL_THRSHLD - 0X3803
250
MEL_EV_DISK_POOL_UTILIZATION_WARNING - 0X3804
250
MEL_EV_FLASH_CACHE_NON_OPTIMAL_DRIVES - 0X3605
250
MEL_EV_DISK_POOL_CAPACITY_DEPLETED - 0X3809
251
MEL_EV_DISK_POOL_UTILIZATION_CRITICAL - 0X3805
251
MEL_EV_DISK_POOL_CORRUPTED_DB_RECORD - 0X380D
252
MEL_EV_DISK_POOL_INSUFFICIENT_MEMORY - 0X380C
252
MEL_EV_VOL_XFER_ALERT - 0X4011
252
MEL_EV_SYMBOL_AUTH_FAIL_CONT_LOCKOUT - 0X5038
253
MEL_EV_SYMBOL_CONT_FAIL - 0X5005
253
MEL_EV_BASE_CONTROLLER_DIAGNOSTIC_FAILED - 0X5100
254
MEL_EV_LOCK_KEY_VALID_ATTEMPTS_EXCEEDED - 0X506D
254
MEL_EV_SYMBOL_CONT_SERVICE_MODE - 0X5040
254
MEL_EV_IOC_CONTROLLER_FAILURE - 0X5101
255
MEL_EV_IOC_FAILURE - 0X5102
255
MEL_EV_SAS_PHY_DISABLED_BYPASSED_DRIVE - 0X5104
256
MEL_EV_SAS_PHY_DISABLED_BYPASSED_PORT - 0X5103
256
MEL_EV_SAS_PHY_DISABLED_LOCAL_WIDE_PORT - 0X5105
257
MEL_EV_SAS_PHY_DISABLED_SHARED_WIDE_PORT - 0X5106
257
MEL_EV_SPM_INVALID_HOST_OS_INDEX_DETECTED - 0X5222
257
MEL_EV_INACTIVE_HOST_PORT_REGISTERED - 0X5224
258
MEL_EV_SPM_INVALID_DEFAULT_OS_INDEX_DETECTED - 0X5223
258
MEL_EV_INACTIVE_INITIATOR_REGISTERED - 0X5225
259
MEL_EV_SAFE_NON_COMPLIANCE - 0X5402
259
MEL_EV_SAFE_MISMATCHED_GK_DEP - 0X5405
260
MEL_EV_SAFE_MISMATCHED_MDT_DEP - 0X5406
260
MEL_EV_SAFE_TIER_NON_COMPLIANCE - 0X5403
260
MEL_EV_DIAG_READ_FAILURE - 0X560D
261
MEL_EV_SAFE_EVAL_EXPIRATION_IMMINENT - 0X5409
261
MEL_EV_DIAG_READ_FAILURE_ALT - 0X560E
262
MEL_EV_DIAG_WRITE_FAILURE - 0X560F
262
MEL_EV_DIAG_WRITE_FAILURE_ALT - 0X5610
262
MEL_EV_DIAG_CONFIG_ERR - 0X5616
263
MEL_EV_DIAG_CONFIG_ERR_ALT - 0X5617
263
MEL_EV_DATABASE_RECOVERY_MODE_ACTIVE - 0X6109
264
MEL_EV_DBM_CONFIG_DB_FULL - 0X6101
264
MEL_EV_DBM_HCK_ALTCTL_NOT_FUNC - 0X6107
264
MEL_EV_MIRROR_DUAL_PRIMARY - 0X6400
265
MEL_EV_MIRROR_DUAL_SECONDARY - 0X6401
265
MEL_EV_MIRROR_UNSYNCHRONIZED - 0X6402
266
MEL_EV_RMTVOL_LINK_DOWN - 0X6503
266
MEL_EV_RVM_WRITE_MODE_INCONSISTENT - 0X6411
266
MEL_EV_RMTVOL_WWN_CHANGE_FAILED - 0X6505
267
MEL_EV_VOLCOPY_FAILED - 0X6600
267
MEL_EV_USM_BAD_LBA_DETECTED - 0X6700
268
MEL_EV_USM_DATABASE_FULL - 0X6703
268
MEL_EV_DDC_AVAILABLE_CRITICAL - 0X6900
269
MEL_EV_SPRI_ACTIVATED - 0X6800
269
MEL_EV_SPRI_WRONG_PASSWORD - 0X6801
269
MEL_EV_BBU_OVERHEATED - 0X7300
270
MEL_EV_FBM_BUNDLE_VIOLATION - 0X7001
270
MEL_EV_BATTERY_EXPIRED - 0X7308
271
MEL_EV_BATTERY_MISSING - 0X7306
271
MEL_EV_INSUFFICIENT_LEARNED_CAPACITY - 0X7301
271
MEL_EV_CACHE_BACKUP_DEVICE_FAILED - 0X7500
272
MEL_EV_CACHE_BACKUP_DEV_WRITE_PROTECTED - 0X7501
272
MEL_EV_BACKUP_COMPONENT_STATUS_UNKNOWN - 0X7506
273
MEL_EV_PITGROUP_REPOSITORY_FULL - 0X7802
273
MEL_EV_PIT_ROLLBACK_PAUSED - 0X7800
273
MEL_EV_PITGROUP_FAILED - 0X7803
274
MEL_EV_VIEW_REPOSITORY_FULL - 0X7805
274
MEL_EV_PIT_PURGED - 0X7807
275
MEL_EV_TPV_REPOSITORY_FULL - 0X7B01
275
MEL_EV_VIEW_REPOSITORY_FAILED - 0X7806
275
MEL_EV_ARVM_AMG_INTERNAL_SUSPENSION - 0X7C02
276
MEL_EV_TPV_REPOSITORY_FAILED - 0X7B02
276
MEL_EV_ARMV_MIRROR_FAILED - 0X7C06
277
MEL_EV_ARVM_AMG_RECOVERY_POINT_LOST - 0X7C04
277
MEL_EV_ARVM_AMG_ROLE_CONFLICT - 0X7C03
277
MEL_EV_ARVM_AMG_SEC_MEM_REP_FULL - 0X7C09
278
MEL_EV_ARVM_AMG_SYNC_PAUSED_ALT_STATE - 0X7C34
278
MEL_EV_ARVM_AMG_ROLE_CHANGE_PAUSED - 0X7C37
279
MEL_EV_SCT_COMMAND_UNSUPPORTED - 0X7D00
279
MEL_EV_HOST_REDUNDANCY_LOST - 0X9102
280
MEL_EV_MULTIPATH_CONFIG_ERROR - 0X9103
280
MEL_EV_SECURITY_AUDIT_LOG_FULL - 0X9200
280
MEL_EV_DIRECTORY_SERV_CONFIG_ERROR - 0X9204
281
Appendix A. Getting Help and Technical Assistance
283
Appendix B. Notices
285
Important Notes
286
Particulate Contamination
286
Trademarks
286
Electronic Emission Notices
287
Telecommunication Regulatory Statement
287
Taiwan BSMI Rohs Declaration
288
Taiwan Import and Export Contact Information
288
Index
289
Advertisement
Lenovo DE120S Manual (158 pages)
Brand:
Lenovo
| Category:
Storage
| Size: 2.32 MB
Table of Contents
Table of Contents
3
Maintain DE2000H or DE4000H Hardware
8
Batteries
8
Controllers
8
Canisters
8
Drives
8
Host Interface Cards (Hics)
8
Host Port Protocol
8
Batteries
9
Requirements for DE2000H or DE4000H Battery Replacement
9
Recovery Guru Alerts
9
Procedure Overview
9
Requirements for Replacing a Battery
9
Prepare to Replace DE2000H or DE4000H Battery
10
About this Task
10
Before You Begin
10
Place Controller Offline (Duplex)
10
Remove DE2000H and DE4000H Canister
12
Remove Failed DE2000H or DE4000H Battery
14
Install New DE2000H or DE4000H Battery
16
Re-Install DE2000H and DE4000H Canister
18
Complete DE2000H or DE4000H Battery Replacement
20
Place Controller Online
20
Controllers
23
Requirements for DE2000H or DE4000H Controller Replacement
23
Requirements for Replacing Controller
23
Duplex Configuration Requirements
24
Replace Controller in DE2000H or DE4000H Duplex Configuration
24
About this Task
24
Step 1: Prepare to Replace Controller (Duplex)
25
Step 2: Remove Failed Controller (Duplex)
28
Step 2A: Remove Controller Canister (Duplex)
28
Step 2B: Remove Battery (Duplex)
30
Step 2C: Remove Host Interface Card (Duplex)
31
Step 3: Install New Controller (Duplex)
33
Step 3A: Install Battery (Duplex)
33
Step 3B: Install Host Interface Card (Duplex)
35
Step 3C: Install New Controller Canister (Duplex)
37
Step 4: Complete Controller Replacement (Duplex)
39
What's Next
40
Canisters
41
Requirements for DE2000H or DE4000H Canister Replacement
41
Power Supply
41
Shelf Types for a Power Supply
41
Requirements for Replacing a Power Supply
42
Power Canister
42
Shelf Types for a Power Canister
42
Requirements for Replacing a Power Canister
43
Fan Canister
43
Shelf Types for a Fan Canister
43
Requirements for Replacing a Fan Canister
44
Replace DE2000H or DE4000H Power Supply (12-Drive or 24-Drive)
45
About this Task
45
Before You Begin
45
Step 1: Prepare to Replace Power Supply
46
Step 2: Remove Failed Power Supply
47
Step 3: Install New Power Supply
48
Step 4: Complete Power Supply Replacement
49
What's Next
49
Replace DE2000H or DE4000H Power Canister (60-Drive)
49
About this Task
49
Before You Begin
50
Step 1: Prepare to Replace Power Canister
50
Step 2: Remove Failed Power Canister
51
Step 3: Install New Power Canister
52
Step 4: Complete Power Canister Replacement
52
Result
53
Replace DE2000H or DE4000H Fan Canister (60-Drive)
53
About this Task
53
Before You Begin
53
Step 1: Prepare to Replace Fan Canister
54
Step 2: Remove Failed Fan Canister and Install New One
55
Step 3: Complete Fan Canister Replacement
57
What's Next
58
Drives
59
Requirements for DE2000H or DE4000H Drive Replacement
59
Shelf Types
59
12-Drive or 24-Drive Shelves
59
60-Drive Shelves
59
Drive Drawer
60
Drive Handling
61
Lenovo DE120S Manual (100 pages)
Brand:
Lenovo
| Category:
Network Hardware
| Size: 2.15 MB
Table of Contents
Table of Contents
3
1 Maintain DE6400 and DE6600 Hardware
6
Batteries
6
Controllers
6
Dimms
6
Drives
6
Fans
6
Host Interface Cards (Hics)
6
Host Port Protocol
6
Power Supplies
6
SAS Expansion Cards
7
2 Batteries
8
Requirements for DE6400 or DE6600 Battery Replacement
8
Recovery Guru Alerts
8
Procedure Overview
8
Requirements
8
Replace DE6400 or DE6600 Battery
9
Step 1: Place Controller Offline
9
Step 2: Remove Controller Canister
10
Step 3: Remove Failed Battery
12
Step 4: Install New Battery
14
Step 5: Reinstall Controller Canister
14
Step 6: Complete Battery Replacement
15
3 Controllers
17
Requirements for DE6400 or DE6600 Controller Replacement
17
Controller Replacement Requirements
17
Replacement While Powered on
17
Replace DE6400 or DE6600 Controller
17
Step 1: Prepare to Replace Controller
18
Step 2: Remove Failed Controller
20
Step 2A: Remove Controller Canister
20
Step 2B: Remove Battery
21
Step 2C: Remove the HIC
23
Step 2D: Remove Power Supply
25
Step 2E: Remove Dimms
26
Step 2F: Remove Fans
28
Step 3: Install New Controller
29
Step 3A: Install Battery
29
Step 3B: Install the HIC
29
Step 3C: Install Power Supply
31
Step 3D: Install Dimms
32
Step 3E: Install Fans
33
Step 3F: Install New Controller Canister
34
Step 4: Complete Controller Replacement
35
4 Dimms
37
Requirements for Replacing a DE6400 or DE6600 DIMM
37
Replace Dimms in DE6400 or DE6600
37
Step 1: Determine if You Need to Replace a DIMM
38
Step 2: Place Controller Offline
38
Step 3: Remove Controller Canister
39
Step 4: Remove Dimms
40
Step 5: Install New Dimms
42
Step 6: Reinstall Controller Canister
43
Step 7: Complete Dimms Replacement
44
5 Drives
46
Requirements for DE6400 or DE6600 Drive Replacement
46
Drive Replacement Requirements
46
Drive Staggering in 24-Drive Controller Shelf
46
Replace Drive in a DE6400 Array
47
Step 1: Prepare to Replace Drive (24-Drive)
48
Step 2: Remove Failed Drive (24-Drive)
48
Step 3: Install New Drive (24-Drive)
49
Step 4: Complete Drive Replacement (24-Drive)
50
Replace Drive in a DE6600 Array
50
Step 1: Prepare to Replace Drive
51
Step 2: Remove Drive
52
Step 3: Install New Drive
52
Step 4: Complete Drive Replacement
53
6 Fans
54
Requirements for DE6400 or DE6600 Fan Replacement
54
Replace a DE6400 or DE6600 Fan
54
Step 1: Place Controller Offline
54
Step 2: Remove Controller Canister
55
Step 3: Remove Failed Fan
57
Step 4: Install New Fan
58
Step 5: Reinstall Controller Canister
59
Step 6: Complete Fan Replacement
60
7 Host Interface Cards
62
Requirements for DE6400 or DE6600 HIC Upgrades
62
Upgrade DE6400 or DE6600 Host Interface Card (HIC)
62
Step 1: Place Controller Shelf Offline
63
Step 2: Remove Controller Canister
64
Step 3: Remove the HIC
66
Step 4: Upgrade the HIC
68
Step 5: Reinstall Controller Canister
69
Step 6: Complete the HIC Upgrade
70
Replace Failed Host Interface Card (HIC) in DE6400 or DE6600
71
Step 1: Place the Controller Offline
72
Step 2: Remove Controller Canister
73
Step 3: Remove the HIC
74
Step 4: Replace the HIC
77
Step 5: Reinstall Controller Canister
78
Step 6: Complete HIC Replacement
79
8 Host Port Protocol Conversion
81
Requirements for DE6400 or DE6600 Host Protocol Conversion
81
Change Host Protocol for a DE6400 or DE6600
81
Step 1: Obtain the Feature Pack Key
81
Step 2: Stop Host I/O
84
Step 3: Change the Feature Pack
84
Complete Host Protocol Conversion for a DE6400 or DE6600
85
9 Power Supplies
87
Requirements for DE6400 or DE6600 Power Supply Replacement
87
Replace a DE6400 or DE6600 Power Supply
87
Step 1: Remove Failed Power Supply
87
Step 2: Install New Power Supply and Complete the Replacement
89
10 SAS Expansion Cards
91
Requirements for DE6400 and DE6600 SAS Expansion Card Replacement
91
Add SAS Expansion Card to DE6400 and DE6600
91
Step 1: Place Controller Shelf Offline
92
Step 2: Remove Controller Canister
93
Step 3: Add the New SAS Expansion Card
94
Step 4: Reinstall the Controller Canister
95
Step 5: Complete SAS Expansion Card Addition
96
11 Appendix
98
General Practice
98
Contacting Support
98
Notices
98
Trademarks
99
Advertisement
Lenovo DE120S Manual (36 pages)
Brand:
Lenovo
| Category:
Storage
| Size: 0.62 MB
Table of Contents
Table of Contents
3
Install and Set up DE2000, DE4000, and DE6000 Storage Systems
4
Overview
5
Install and Set up 60-Drives
7
Prepare for Installation
7
Install the Hardware
9
Cable the Shelves
13
Complete Storage System Setup and Configuration
16
Step 1: Cable the Data Hosts
16
Option 1: Direct-Attach Topology
16
Option 2: Fabric Topology
17
Step 2: Connect and Configure the Management Connection
17
Option 1: DHCP Server
17
Option 2: Static IP Address
18
Step 3: Configure and Manage Your Storage System
20
Install and Set up 12 and 24-Drives
21
Prepare for Installation
21
Install the Hardware
23
Connect the Cables
26
Complete Storage System Setup and Configuration
29
Step 1: Cable the Data Hosts
29
Option 1: Direct-Attach Topology
29
Option 2: Fabric Topology
29
Step 2: Connect and Configure the Management Connection
30
Option 1: DHCP Server
30
Option 2: Static IP Address
31
Step 3: Configure Storage System
33
Appendix
34
Contacting Support
34
Notices
34
Trademarks
35
Lenovo DE120S Installation And Setup Instructions (4 pages)
Brand:
Lenovo
| Category:
Storage
| Size: 31.44 MB
Advertisement
Related Products
Lenovo ThinkSystem D3284
Lenovo DE2000H
Lenovo DE4000H
Lenovo DE6000F
Lenovo DE4000F
Lenovo DE240S
Lenovo DE6000H
Lenovo ThinkSystem DW612S Neptune DWC
Lenovo ThinkSystem DE120S 7Y63
Lenovo ThinkSystem DE6000H 7Y70
Lenovo Categories
Laptop
Desktop
Server
Monitor
Tablet
More Lenovo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL