Sign In
Upload
Manuals
Brands
Mitsubishi Electric Manuals
Air Conditioner
CITY MULTI PEFY-P36VMS-E-S
Mitsubishi Electric CITY MULTI PEFY-P36VMS-E-S Manuals
Manuals and User Guides for Mitsubishi Electric CITY MULTI PEFY-P36VMS-E-S. We have
1
Mitsubishi Electric CITY MULTI PEFY-P36VMS-E-S manual available for free PDF download: Data Book
Mitsubishi Electric CITY MULTI PEFY-P36VMS-E-S Data Book (350 pages)
Brand:
Mitsubishi Electric
| Category:
Air Conditioner
| Size: 34.73 MB
Table of Contents
Ceiling Concealed (Middle Static Pressure Type)
30
Table of Contents
30
Specifications
31
External Dimensions
37
Center of Gravity
41
Electrical Wiring Diagrams
42
Sound Levels
45
NC Curves
47
Fan Characteristics Curves
61
Ceiling Cassette (1-Way Flow Type)
72
Specifications
73
External Dimensions
74
Center of Gravity
75
Electrical Wiring Diagrams
76
NC Curves
77
Sound Levels
77
Airflow Distributions
78
Temperature Distributions
78
Temperature/Airflow Distributions
78
Plfy-P-Vbm-E-S
80
Specifications
81
External Dimensions
83
Center of Gravity
84
Electrical Wiring Diagrams
85
NC Curves
86
Sound Levels
86
Temperature Distributions
87
Temperature/Airflow Distributions
87
Airflow Distributions
88
Air Outlet Shutter Plate
89
Optional Parts
89
Optional Parts Line up for the Indoor Unit
89
High Efficiency Filter Element
90
Multi-Function Casement
90
Automatic Filter Elevation Panel
91
Move-Eye Sensor Corner Panel
91
Duct Flange for Fresh Air Intake
92
Space Panel
92
Wireless Signal Receiver
92
Wall Mounted
94
Specifications
95
External Dimensions
97
Center of Gravity
99
Electrical Wiring Diagrams
100
NC Curves
102
Sound Levels
102
Temperature Distributions
103
Temperature/Airflow Distributions
103
Airflow Distributions
104
Drain Pump
105
External LEV Box
105
Optional Parts
105
Optional Parts Line up for the Indoor Unit
105
Lossnay
106
Performance
109
Specifications
110
Sample Installations
113
Electrical Installations
114
Electrical Wiring Diagrams
115
Oa Processing Unit
118
Specifications
120
Measurement Condition
121
NC Curves
121
Sound Levels
121
Fan Characteristics Curves
122
External Dimensions
123
Electrical Wiring Diagrams
124
Capacity Table
126
Cooling Capacity with PUMY-P100-140YHMC-C/VHMC-S
127
Cooling [Ceiling Concealed (Slim Type)]
127
Cooling Capacity with PUMY-P200-250YKMC-C
129
Cooling Capacity with PUHY-P300YRJC-A
131
Cooling Capacity with PUHY-P350-400YRJC-A
133
Cooling Capacity with PUHY-P450YRJC-A
135
Cooling Capacity with PUMY-P100-140YHMC-C/VHMC-S
137
Cooling [Ceiling Concealed (Middle Static Pressure Type)]
137
Cooling Capacity with PUMY-P200-250YKMC-C
141
Cooling Capacity with PUHY-P300YRJC-A
145
Cooling Capacity with PUHY-P350-400YRJC-A
149
Cooling Capacity with PUHY-P450YRJC-A
153
Cooling Capacity with PUMY-P100-140YHMC-C/VHMC-S
157
Cooling [Ceiling Cassette (1-Way Flow Type)]
157
Cooling Capacity with PUMY-P200-250YKMC-C
158
Cooling Capacity with PUHY-P300YRJC-A
159
Cooling Capacity with PUHY-P350-400YRJC-A
160
Cooling Capacity with PUHY-P450YRJC-A
161
Cooling Capacity with PUMY-P100-140YHMC-C/VHMC-S
162
Cooling [Ceiling Cassette (4-Way Flow Type)]
162
Cooling Capacity with PUMY-P200-250YKMC-C
163
Cooling Capacity with PUHY-P300YRJC-A
164
Cooling Capacity with PUHY-P350-400YRJC-A
165
Cooling Capacity with PUHY-P450YRJC-A
166
Cooling Capacity with PUMY-P100-140YHMC-C/VHMC-S
167
Cooling [Wall Mounted]
167
Cooling Capacity with PUMY-P200-250YKMC-C
168
Cooling Capacity with PUHY-P300YRJC-A
169
Cooling Capacity with PUHY-P350-400YRJC-A
170
Cooling Capacity with PUHY-P450YRJC-A
171
Heating Capacity with PUMY-P100-140YHMC-C/VHMC-S
172
Heating [All Indoor Units]
172
Heating Capacity with PUMY-P200-250YKMC-C
174
Heating Capacity with PUHY-P300YRJC-A
176
Heating Capacity with PUHY-P350-400YRJC-A
178
Heating Capacity with PUHY-P450YRJC-A
180
Heating Capacity with PUHY-P300YRJC-A "COP Priority Mode
182
Heating Capacity with PUHY-P350-400YRJC-A "COP Priority Mode
184
Heating Capacity with PUHY-P450YRJC-A "COP Priority Mode
186
Section 8
190
Outdoor Units
191
Specifications
191
External Dimensions
195
Center of Gravity
198
Electrical Wiring Diagrams
199
Sound Levels
202
Correction by Temperature
204
Correction by Total Indoor
206
Correction by Refrigerant Piping Length
210
Correction at Frost and Defrost
211
Operation Temperature Range
212
Joint
213
Optional Parts
213
Header
214
Section 9
216
Outdoor Units
217
Specifications
217
External Dimensions
219
Center of Gravity
223
Electrical Wiring Diagrams
224
Capacity Tables
226
Correction by Temperature
226
Correction by Total Indoor
232
Correction by Refrigerant Piping Length
234
Correction at Frost and Defrost
235
Joint
236
Header
237
City Multi 3. Controller
238
Controller
239
MITSUBISHI Electric's Air-Conditioner Network System. (MELANS)
239
1-1.Function Table of Controllers
240
2-1.MA Remote Controller [PAR-30MAAC]
241
Local Remote Controller
241
2-2.MA Remote Controller [PAR-21MAA]
242
2-4.Simple MA Remote Controller [PAC-YT51CRB]
244
2-5.Simple ME Remote Controller [PAC-SE51CRA]
245
2-6.Wireless Remote Controller [PAR-FL32MA / PAR-FA32MA]
246
2-7.LOSSNAY Remote Controller [PZ-52SF]
247
3-1.ON/OFF Remote Controller [PAC-YT40ANRA]
248
System Remote Controller
248
3-2.Advanced Touch Controller [AT-50A]
250
3-3.Power Supply Unit [PAC-SC51KUA]
251
3-4.Bm Adapter [Bac-Hd150]
260
ON ORKS Interface [LMAP02-E]
262
3-6.DIDO Controller [PAC-YG66DCA]
264
4-1.S, y Series
273
System Component
273
4-2.Outdoor Unit Input/Output Connector
275
4-3.Indoor Unit "-E (C)" Type Input/Output Connector
277
City Multi System Design S Series
280
1-1.General Cautions
281
Electrical Work
281
1-4.Power Supply Examples
285
M-NET Control
286
2-2.Transmission Cable Specifications
287
2-3.System Configuration Restrictions
288
2-4.Address Setting
291
3-1.R410A Piping Material
297
Piping Design
297
3-2.Piping Design
298
3-3.Refrigerant Charging Calculation
300
4-1.Requirement on Installation Site
302
Outdoor Installation
302
4-3.Piping Direction
305
5-1.General Precautions
306
Installation Information
306
5-2.Precautions for Indoor Unit
307
5-3.Precautions for Fresh Air Intake Type Indoor Unit
308
5-4.Precautions for Outdoor Unit/Heat Source Unit
308
5-5.Precautions for Control-Related Items
309
6-1.Refrigerant Property
310
6-2.Confirm the Critical Concentration and Take Countermeasure
310
Caution for Refrigerant Leakage
310
City Multi System Design y Series
312
1-1.General Cautions
313
Electrical Work
313
1-3.Power Cable Specifications
316
M-NET Control
319
2-4.Address Setting
323
Piping Design
333
3-2.Piping Design
334
Outdoor Installation
336
4-3.Piping Direction
339
4-4.Weather Countermeasure
342
4-5.Caution on Selecting Outdoor Units
343
5-1.General Precautions
344
Installation Information
344
6-1.Refrigerant Property
348
Caution for Refrigerant Leakage
348
Advertisement
Advertisement
Related Products
Mitsubishi Electric PEFY-P36NMHU-E
Mitsubishi Electric CITY MULTI PEFY-P36NMAU-E
Mitsubishi Electric PEFY-P36
Mitsubishi Electric CITY MULTI PEFY-P36NMAU-E3
Mitsubishi Electric CITY MULTI PEFY-P36NMHU-E-OA
Mitsubishi Electric CITY MULTI PEFY-P36NMHU-E2
Mitsubishi Electric City Multi PEFY-P36NMAU-E4
Mitsubishi Electric PEFY-P30NMHU-E
Mitsubishi Electric PEFY-P32VMS1(L)-E
Mitsubishi Electric CITY MULTI PEFY-P30NMAU-E3
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL