Sign In
Upload
Manuals
Brands
Mitsubishi Electric Manuals
Inverter
FR-F740-02600-EC
Mitsubishi Electric FR-F740-02600-EC Manuals
Manuals and User Guides for Mitsubishi Electric FR-F740-02600-EC. We have
5
Mitsubishi Electric FR-F740-02600-EC manuals available for free PDF download: Instruction Manual, Installation Manuallines
Mitsubishi Electric FR-F740-02600-EC Instruction Manual (341 pages)
F700 Series
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 17.53 MB
Table of Contents
Instruction Manual
1
Table of Contents
4
Outline
10
Product Checking and Parts Identification
11
Inverter and Peripheral Devices
12
Peripheral Devices
13
Method of Removal and Reinstallation of the
14
Installation of the Inverter and Enclosure Design
16
Inverter Installation Environment
16
Enclosure Design
17
Cooling System Types for Inverter Enclosure
18
Inverter Placement
18
Wiring
20
Wiring
21
Terminal Connection Diagram
21
EMC Filter
22
Main Circuit Terminal Specifications
23
Specification of Main Circuit Terminal
23
Terminal Arrangement of the Main Circuit Terminal, Power Supply and the Motor Wiring
23
Cables and Wiring Length
26
When Connecting the Control Circuit and the Main Circuit Separately to the Power Supply
29
Control Circuit Specifications
31
Control Circuit Terminals
31
Changing the Control Logic
34
Control Circuit Terminal Layout
36
Wiring Instructions
37
When Connecting the Operation Panel Using a Connection Cable
38
Terminal Block
39
Communication Operation
39
Connection of Stand-Alone Option Units
40
Connection of the Brake Unit (FR-BU2)
40
Connection of the Brake Unit (FR-BU/MT-BU5)
42
Connection of the Brake Unit (BU Type)
44
Connection of the High Power Factor Converter (FR-HC/MT-HC)
44
Connection of the Power Regeneration Common Converter (FR-CV)(01160 or Less)
46
Connection of the Power Regeneration Converter (MT-RC) (01800 or More)
47
Connection of the Power Factor Improving DC Reactor (FR-HEL)
47
Precautions for Use of the Inverter
48
EMC and Leakage Currents
49
Leakage Currents and Countermeasures
49
EMC Measures
51
Power Supply Harmonics
53
Installation of a Reactor
54
Power-Off and Magnetic Contactor (MC)
54
Inverter-Driven 400V Class Motor
55
Precautions for Use of the Inverter
56
Failsafe of the System Which Uses the Inverter
58
Parameters
60
Operation Panel (FR-DU07)
61
Parts of the Operation Panel (FR-DU07)
61
Basic Operation (Factory Setting)
62
Changing the Parameter Setting Value
63
Setting Dial Push
63
Parameter List
64
Adjustment of the Output Torque (Current) of the Motor
76
Manual Torque Boost (Pr. 0, Pr. 46)
76
Simple Magnetic Flux Vector Control (Pr.80, Pr.90)
77
Slip Compensation (Pr. 245 to Pr. 247)
78
Stall Prevention Operation (Pr. 22, Pr. 23, Pr. 48, Pr. 49, Pr. 66, Pr. 148, Pr. 149, Pr. 154, Pr. 156, Pr. 157)
79
Stall Prevention Operation
79
Multiple Rating (Pr.570)
84
Limiting the Output Frequency
85
Maximum/Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)
85
Avoiding Mechanical Resonance Points (Frequency Jump) (Pr. 31 to Pr. 36)
86
V/F Pattern
87
Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)
87
Load Pattern Selection (Pr. 14)
89
Adjustable 5 Points V/F (Pr. 71, Pr. 100 to Pr. 109)
90
Frequency Setting by External Terminals
91
Multi-Speed Setting Operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
91
Jog Operation (Pr. 15, Pr. 16)
93
Input Compensation of Multi-Speed and Remote Setting (Pr. 28)
95
Remote Setting Function (Pr. 59)
96
Setting of Acceleration/Deceleration Time and Acceleration/Deceleration Pattern
99
Setting of the Acceleration and Deceleration Time (Pr.7, Pr.8, Pr.20, Pr.21, Pr.44, Pr.45)
99
Starting Frequency and Start-Time Hold Function (Pr.13, Pr.571)
101
Acceleration/Deceleration Pattern (Pr.29, Pr.140 to Pr.143)
102
Selection and Protection of a Motor
104
Motor Protection from Overheat (Electronic Thermal Relay Function) (Pr. 9, Pr. 51)
104
Applied Motor (Pr. 71)
108
Motor Brake and Stop Operation
109
DC Injection Brake (Pr. 10 to Pr. 12)
109
Selection of a Regenerative Brake and DC Feeding (Pr. 30, Pr. 70)
111
Stop Selection (Pr. 250)
116
Output Stop Function (Pr.522)
117
Function Assignment of External Terminal and Control
119
Input Terminal Function Selection (Pr. 178 to Pr. 189)
119
Inverter Output Shutoff Signal (MRS Signal, Pr. 17)
121
Condition Selection of Function Validity by the Second Function Selection Signal (RT) (RT Signal, Pr. 155)
122
Start Signal Selection (STF, STR, STOP Signal, Pr. 250)
123
Output Terminal Function Selection (Pr. 190 to Pr. 196)
125
Detection of Output Frequency (SU, FU, FU2 Signal, Pr. 41 to Pr. 43, Pr. 50)
129
Output Current Detection Function (Y12 Signal, Y13 Signal, Pr. 150 to Pr. 153, Pr. 166, Pr. 167)
130
Output Current Detection Function
130
Remote Output Function (REM Signal, Pr. 495 to Pr. 497)
132
Pulse Train Output of Output Power (Y79 Signal, Pr. 799)
133
Monitor Display and Monitor Output Signal
134
Speed Display and Speed Setting (Pr. 37, Pr. 144)
134
DU/PU Monitor Display Selection (Pr. 52, Pr. 54, Pr. 158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564, Pr. 891)
135
DU/PU Monitor Display Selection
135
CA, am Terminal Function Selection (Pr.55, Pr.56, Pr.867, Pr.869)
140
Terminal CA, am Calibration (Calibration Parameter C0 (Pr. 900), C1 (Pr. 901), C8 (Pr.930) to C11 (Pr. 931))
142
Operation Selection at Power Failure and Instantaneous Power Failure
145
Automatic Restart after Instantaneous Power Failure / Flying Start (Pr. 57, Pr. 58, Pr. 162 to Pr. 165, Pr. 299, Pr. 611)
145
Instantaneous Power Failure
147
Power Failure-Time Deceleration-To-Stop Function (Pr. 261 to Pr. 266 )
149
Operation Setting at Fault Occurrence
152
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
152
Fault Code Output Selection (Pr.76)
154
Input/Output Phase Loss Protection Selection (Pr. 251, Pr. 872)
155
Energy Saving Operation and Energy Saving Monitor
156
Energy Saving Control and Optimum Excitation Control (Pr. 60)
156
Energy Saving Monitor (Pr. 891 to Pr. 899)
157
Motor Noise, EMI Measures, Mechanical Resonance
162
PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240, Pr. 260)
162
Speed Smoothing Control (Pr. 653, Pr. 654)
163
Frequency Setting by Analog Input (Terminal 1, 2, 4)
164
Analog Input Selection (Pr. 73, Pr. 267)
164
Analog Input Compensation (Pr. 73, Pr. 242, Pr. 243, Pr. 252, Pr. 253)
169
Response Level of Analog Input and Noise Elimination (Pr. 74)
170
Bias and Gain of Frequency Setting Voltage (Current) (Pr. 125, Pr. 126, Pr. 241, C2(Pr. 902) to C7(Pr. 905))
171
Operation Display
175
4Ma Input Check of Current Input (Pr. 573)
176
Misoperation Prevention and Parameter Setting Restriction
178
Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)
178
Parameter Write Selection (Pr. 77)
181
Reverse Rotation Prevention Selection (Pr. 78)
182
Display of Applied Parameters and User Group Function (Pr. 160, Pr. 172 to Pr. 174)
182
Selection of Operation Mode and Operation Location
184
Operation Mode Selection (Pr. 79)
184
Operation Mode at Power on (Pr. 79, Pr. 340)
192
Start Command Source and Speed Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
193
Communication Operation and Setting
198
Wiring and Configuration of PU Connector
198
System Configuration
199
Wiring and Arrangement of RS-485 Terminals
200
Initial Settings and Specifications of RS-485 Communication (Pr. 117 to Pr. 124, Pr. 331 to Pr. 337, Pr. 341, Pr. 549)
203
Communication EEPROM Write Selection (Pr. 342)
204
Mitsubishi Inverter Protocol (Computer Link Communication)
205
Run Command
215
Modbus-RTU Communication Specifications (Pr. 331, Pr. 332, Pr. 334, Pr. 343, Pr. 539, Pr. 549)
216
Special Operation and Frequency Control
228
PID Control (Pr. 127 to Pr. 134, Pr. 241, Pr. 553, Pr. 554, Pr. 575 to Pr. 577, C42 (Pr. 934) to C45 (Pr. 935))
228
Special Operation and Frequency Control
230
Bypass-Inverter Switchover Function (Pr. 135 to Pr. 139, Pr. 159)
240
Advanced PID Function (Pump Function) (Pr. 554, Pr. 575 to Pr. 591)
245
Traverse Function (Pr. 592 to Pr. 597)
255
Regeneration Avoidance Function (Pr. 882 to Pr. 886)
257
Useful Functions
259
Cooling Fan Operation Selection (Pr. 244)
259
Display of the Life of the Inverter Parts (Pr. 255 to Pr .259)
260
Maintenance Timer Alarm (Pr. 503, Pr. 504)
263
Current Average Value Monitor Signal (Pr. 555 to Pr. 557)
264
Free Parameter (Pr. 888, Pr. 889)
266
Setting from the Parameter Unit, Operation Panel
267
PU Display Language Selection (Pr. 145)
267
Operation Panel Frequency Setting/Key Lock Selection (Pr. 161)
267
Buzzer Control (Pr. 990)
269
PU Contrast Adjustment (Pr. 991)
269
Parameter Clear
270
All Parameter Clear
271
Parameter Copy and Parameter Verification
272
Parameter Copy
272
Parameter Verification
273
Check and Clear of the Faults History
274
Protective Functions
276
Reset Method of Protective Function
277
List of Fault or Alarm Display
278
Causes and Corrective Actions
279
Correspondences between Digital and Actual Characters
290
Check First When You Have a Trouble
291
Motor Does Not Start
291
Motor or Machine Is Making Abnormal Acoustic Noise
293
Inverter Generates Abnormal Noise
293
Motor Generates Heat Abnormally
293
Motor Rotates in the Opposite Direction
294
Speed Greatly Differs from the Setting
294
Acceleration/Deceleration Is Not Smooth
294
Speed Varies During Operation
295
Operation Mode Is Not Changed Properly
295
Operation Panel (FR-DU07) Display Is Not Operating
296
Motor Current Is too Large
296
Speed Does Not Accelerate
297
Unable to Write Parameter Setting
297
Power Lamp Is Not Lit
297
Precautions for Maintenance and Inspection
298
Inspection Item
299
Daily Inspection
299
Periodic Inspection
299
Daily and Periodic Inspection
300
Display of the Life of the Inverter Parts
301
Checking the Inverter and Converter Modules
301
Cleaning
302
Replacement of Parts
302
Inverter Replacement
306
Measurement of Main Circuit Voltages, Currents and Powers
307
Measurement of Voltages and Currents
307
Measurement of Powers
309
Measurement of Voltages and Use of PT
309
Measurement of Currents
310
Use of CT and Transducer
310
Measurement of Inverter Input Power Factor
310
Measurement of Converter Output Voltage (Across Terminals P/+ - N/-)
311
Insulation Resistance Test Using Megger
311
Pressure Test
311
Specifications
312
Rating
313
Common Specifications
314
Outline Dimension Drawings
316
Inverter Outline Dimension Drawings
316
Heatsink Protrusion Attachment Procedure
325
When Using a Heatsink Protrusion Attachment (FR-A7CN)
325
Protrusion of Heatsink of the FR-F740-04320 or more
325
Appendices
328
Appendix 1 for Customers Who Are Replacing the Conventional Model with this Inverter
329
Appendix 1-1 Replacement of the FR-F500 Series
329
Appendix 1-2 Replacement of the FR-A100 <EXCELENT> Series
330
Instructions for Installation
330
Appendix 2 Parameter Clear, Parameter Copy and Instruction Code List
331
Appendix 3 Specification Change
339
Appendix 3-1 SERIAL Number Check
339
Appendix 3-2 Changed Functions
339
Advertisement
Mitsubishi Electric FR-F740-02600-EC Instruction Manual (280 pages)
Frequency Inverter
Brand:
Mitsubishi Electric
| Category:
DC Drives
| Size: 9.86 MB
Table of Contents
Table of Contents
5
Inverter and Peripheral Devices
13
Peripheral Devices
14
Wiring
15
Terminal Connection Diagram
15
EMC Filter
16
Main Circuit Terminal Specifications
17
Specification of Main Circuit Terminal
17
Terminal Arrangement of the Main Circuit Terminal, Power Supply and the Motor Wiring
17
Cables and Wiring Length
20
Control Circuit Specifications
23
Control Circuit Terminals
23
Control Circuit Terminal Layout
25
Wiring Instructions
26
When Connecting the Control Circuit and the Main Circuit Separately to the Power Supply (Separate Power)
27
Changing the Control Logic
29
Connection of Stand-Alone Option Units
31
Connection of the Brake Unit (FR-BU/MT-BU5)
31
Connection of the Brake Unit (BU Type)
33
Connection of the High Power Factor Converter (FR-HC/MT-HC)
33
Connection of the Power Regeneration Common Converter (FR-CV)
35
Connection of Power Regeneration Converter (MT-RC) (01800 or More)
36
Connection of the Power Factor Improving DC Reactor (FR-HEL)
36
When Connecting the Operation Panel Using a Connection Cable
37
Precautions for Use of the Inverter
38
Enclosure Design
39
Inverter Installation Environment
39
Cooling System Types for Inverter Enclosure
41
Inverter Placement
41
Precautions for Use of the Inverter
43
Noise and Leakage Currents
45
Leakage Currents and Countermeasures
45
Inverter-Generated Noises and Their Reduction Techniques
47
Power Supply Harmonics
49
Installation of a Reactor
50
Power-Off and Magnetic Contactor (MC)
50
Inverter-Driven 400V Class Motor
51
Parameters
52
Parameter List
53
Adjust the Output Torque of the Motor (Current)
68
Manual Torque Boost (Pr. 0, Pr. 46)
68
Simple Magnetic Flux Vector Control (Pr.80, Pr.90)
69
Slip Compensation (Pr. 245 to Pr. 247)
70
Stall Prevention Operation (Pr. 22, Pr. 23, Pr. 48, Pr. 49, Pr. 66, Pr. 148, Pr. 149, Pr. 154, Pr. 156, Pr. 157)
71
Multiple Rating (Pr.570)
76
Limit the Output Frequency
77
Maximum/Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)
77
Avoid Mechanical Resonance Points (Frequency Jump) (Pr. 31 to Pr. 36)
78
Set V/F Pattern
79
Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)
79
Load Pattern Selection (Pr. 14)
81
Adjustable 5 Points V/F (Pr. 71, Pr. 100 to Pr. 109)
82
Frequency Setting by External Terminals
83
Multi-Speed Setting Operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
83
Jog Operation (Pr. 15, Pr. 16)
83
Jog Operation (Pr. 15, Pr. 16)
85
Input Compensation of Multi-Speed and Remote Setting (Pr. 28)
87
Remote Setting Function (Pr. 59)
88
Setting of Acceleration/Deceleration Time and Acceleration/Deceleration Pattern
90
Setting of the Acceleration and Deceleration Time (Pr.7, Pr.8, Pr.20, Pr.21, Pr.44, Pr.45)
90
Starting Frequency and Start-Time Hold Function (Pr.13, Pr.571)
92
Acceleration/Deceleration Pattern (Pr.29, Pr.140 to Pr.143)
93
Selection and Protection of a Motor
94
Motor Protection from Overheat (Electronic Thermal Relay Function) (Pr. 9)
94
Applied Motor (Pr. 71)
96
Motor Brake and Stop Operation
97
DC Injection Brake (Pr. 10 to Pr. 12)
97
Selection of a Regenerative Brake (Pr. 30, Pr. 70)
99
Stop Selection (Pr. 250)
100
Function Assignment of External Terminal and Control
101
Input Terminal Function Selection (Pr. 178 to Pr. 189)
101
Inverter Output Shutoff Signal (MRS Signal, Pr. 17)
103
Operation Condition Selection of Second Function Selection Signal (RT) (Terminal RT, Pr. 155)
104
Start Signal Selection (Terminal STF, STR, STOP, Pr. 250)
105
Output Terminal Function Selection (Pr. 190 to Pr. 196)
107
Detection of Output Frequency (SU, FU, FU2 Signal, Pr. 41 to Pr. 43, Pr. 50)
111
Output Current Detection Function (Y12 Signal, Y13 Signal, Pr. 150 to Pr. 153, Pr. 166, Pr. 167)
112
Remote Output Function (REM Signal, Pr. 495 to Pr. 497)
114
Monitor Display and Monitor Output Signal
115
Speed Display and Speed Setting (Pr. 37, Pr. 144)
115
DU/PU Monitor Display Selection (Pr. 52, Pr. 54, Pr. 158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564, Pr. 891)
116
CA, am Terminal Function Selection (Pr.55, Pr.56, Pr.867, Pr.869)
121
Terminal CA, am Calibration (Calibration Parameter C0 (Pr. 900), C1 (Pr. 901), C8 (Pr.930) to C11 (Pr. 931))
122
Operation Selection at Power Failure and Instantaneous Power Failure
125
Automatic Restart after Instantaneous Power Failure / Flying Start (Pr. 57, Pr. 58, Pr. 162 to Pr. 165, Pr. 299, Pr. 611)
125
Power Failure-Time Deceleration-To-Stop Function (Pr. 261 to Pr. 266 )
129
Operation Setting at Alarm Occurrence
131
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
131
Alarm Code Output Selection (Pr.76)
133
Input/Output Phase Failure Protection Selection (Pr. 251, Pr. 872)
134
Energy Saving Operation and Energy Saving Monitor
135
Energy Saving Control and Optimum Excitation Control (Pr. 60)
135
Energy Saving Monitor (Pr. 891 to Pr. 899)
136
Motor Noise, Noise Reduction
141
PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240, Pr. 260)
141
Frequency Setting by Analog Input (Terminal 1, 2, 4)
142
Analog Input Selection (Pr. 73, Pr. 267)
142
Analog Input Compensation (Pr. 73, Pr. 242, Pr. 243, Pr. 252, Pr. 253)
144
Input Filter Time Constant (Pr. 74)
145
Bias and Gain of Frequency Setting Voltage (Current) (Pr. 125, Pr. 126, Pr. 241, C2(Pr. 902) to C7(Pr. 905))
146
4Ma Input Check of Current Input (Pr. 573)
151
Misoperation Prevention and Parameter Setting Restriction
153
Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)
153
Parameter Write Selection (Pr. 77)
156
Reverse Rotation Prevention Selection (Pr. 78)
157
Display of Applied Parameters and User Group Function (Pr. 160, Pr. 172 to Pr. 174)
157
Selection of Operation Mode and Operation Location
159
Operation Mode Selection (Pr. 79)
159
Operation Mode at Power on (Pr. 79, Pr. 340)
167
Operation Command Source and Speed Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
168
Communication Operation and Setting
173
Wiring and Configuration of PU Connector
173
Wiring and Arrangement of RS-485 Terminals
175
Initial Settings and Specifications of RS-485 Communication (Pr. 117 to Pr. 124, Pr. 331 to Pr. 337, Pr. 341, Pr. 549)
178
Communication EEPROM Write Selection (Pr. 342)
179
Mitsubishi Inverter Protocol (Computer Link Communication)
180
Modbus-RTU Communication Specifications (Pr. 331, Pr. 332, Pr. 334, Pr. 343, Pr. 549)
190
Special Operation and Frequency Control
201
PID Control (Pr. 127 to Pr. 134, Pr. 575 to Pr. 577)
201
Commercial Power Supply-Inverter Switchover Function (Pr. 135 to Pr. 139, Pr. 159)
209
Advanced PID Function (Pump Function) (Pr. 575 to Pr. 591)
214
Traverse Function (Pr. 592 to Pr. 597)
223
Regeneration Avoidance Function (Pr. 882 to Pr. 886)
225
Useful Functions
227
Cooling Fan Operation Selection (Pr. 244)
227
Display of the Life of the Inverter Parts (Pr. 255 to Pr .259)
228
Maintenance Timer Alarm (Pr. 503, Pr. 504)
230
Current Average Value Monitor Signal (Pr. 555 to Pr. 557)
231
Free Parameter (Pr. 888, Pr. 889)
233
Setting from the Parameter Unit, Operation Panel
234
PU Display Language Selection (Pr. 145)
234
Operation Panel Frequency Setting/Key Lock Operation Selection (Pr. 161)
234
Buzzer Control (Pr. 990)
236
PU Contrast Adjustment (Pr. 991)
236
Parameter Clear
237
All Parameter Clear
238
Parameter Copy and Parameter Verification
239
Parameter Copy
239
Parameter Verification
240
Check and Clear of the Alarm History
241
Protective Functions
244
List of Alarm Display
245
Causes and Corrective Actions
246
Reset Method of Protective Function
257
Correspondences between Digital and Actual Characters
257
Characters
257
Meters and Measuring Methods
258
Measurement of Powers
258
Measurement of Voltages and Use of PT
259
Measurement of Currents
259
Use of CT and Transducer
260
Measurement of Inverter Input Power Factor
260
Measurement of Converter Output Voltage (Across Terminals P/+ - N/-)
260
Check First When You Have Troubles
261
Motor Does Not Rotate as Commanded
261
Motor Generates Abnormal Noise
261
Motor Generates Heat Abnormally
261
Motor Rotates in Opposite Direction
262
Speed Greatly Differs from the Setting
262
Acceleration/Deceleration Is Not Smooth
262
Motor Current Is Large
262
Speed Does Not Increase
262
Speed Varies During Operation
262
Operation Mode Is Not Changed Properly
263
Operation Panel (FR-DU07) Display Is Not Operating
263
POWER Lamp Is Not Lit
263
Parameter Write Cannot be Performed
263
Specifications
264
Rating
265
Common Specifications
266
Outline Dimension Drawings
268
Inverter Outline Dimension Drawings
268
Outline Dimension Drawings
269
Operation Panel (FR-DU07) Outline Dimension Drawings
275
Parameter Unit (FR-PU04) Outline Dimension Drawings
275
Heatsink Protrusion Attachment Procedure
276
When Using a Heatsink Protrusion Attachment (FR-A7CN)
276
Protrusion of Heatsink of the FR-F740-04320 or more
276
Mitsubishi Electric FR-F740-02600-EC Instruction Manual (144 pages)
Brand:
Mitsubishi Electric
| Category:
DC Drives
| Size: 10.92 MB
Table of Contents
Table of Contents
3
Contents 1 Product Checking and Parts Identification
8
Installation and Wiring
9
Peripheral Devices
10
Method of Removal and Reinstallation of the
11
Installation of the Inverter and Instructions
13
Wiring
14
Terminal Connection Diagram
14
EMC Filter
15
Specification of Main Circuit Terminal
16
Terminal Arrangement of the Main Circuit Terminal, Power Supply and the Motor Wiring
16
Control Circuit Terminals
21
When Connecting the Operation Panel Using a Connection Cable
29
Terminal Block
29
Communication Operation
30
Power-Off and Magnetic Contactor (MC)
31
Precautions for Use of the Inverter
32
Drive the Motor
34
Step of Operation
34
Operation Panel (FR-DU07)
35
Parts of the Operation Panel (FR-DU07)
35
Basic Operation (Factory Setting)
36
Operation Lock (Press [MODE] for an Extended Time (2S))
37
Monitoring of Output Current and Output Voltage
38
First Priority Monitor
38
Setting Dial Push
38
Overheat Protection of the Motor by the Inverter (Pr. 9)
39
Start/Stop from the Operation Panel (PU Operation Mode)
40
Set the Set Frequency to Operate (Example: Performing Operation at 30Hz)
40
Use the Setting Dial Like a Potentiometer to Perform Operation
41
Use Switches to Give a Start Command and a Frequency Command (Multi-Speed Setting)
42
Perform Frequency Setting by Analog (Voltage Input)
44
Perform Frequency Setting by Analog (Current Input)
46
Make a Start and Stop with Terminals (External Operation)
48
Use the Set Frequency Set by the Operation Panel (Pr. 79 = 3)
48
Use Switches to Give a Start Command and a Frequency Command (Multi-Speed Setting) (Pr. 4 to Pr. 6)
50
Perform Frequency Setting by Analog (Voltage Input)
52
Change the Frequency (50Hz) of the Maximum Value of Potentiometer (at 5V)
53
Perform Frequency Setting by Analog (Current Input)
54
Change the Frequency (50Hz) of the Maximum Value of Potentiometer (at 20Ma)
55
Adjustment
56
Simple Mode Parameter List
56
Increase the Starting Torque (Pr. 0)
57
Limit the Maximum and Minimum Output Frequency (Pr. 1, Pr. 2)
58
When the Rated Motor Frequency Is 60Hz (Pr. 3)
59
Change Acceleration and Deceleration Time (Pr. 7, Pr. 8)
60
Energy Saving Operation (Pr. 60)
61
Energy Saving Operation Mode (Setting "4")
61
Optimum Excitation Control Mode (Setting "9")
61
Selection of the Operation Command and Frequency Command Locations (Pr. 79)
63
Parameter Clear
64
All Parameter Clear
65
Parameter Copy and Parameter Verification
66
Parameter Copy
66
Parameter Verification
67
Troubleshooting
68
List of Alarm Display
68
Causes and Corrective Actions
69
Reset Method of Protective Function
80
Correspondences between Digital and Actual Characters
80
Check and Clear of the Alarm History
81
Check First When You Have Troubles
83
Motor Does Not Rotate as Commanded
83
Motor Generates Abnormal Noise
83
Motor Generates Heat Abnormally
83
Motor Rotates in Opposite Direction
84
Speed Greatly Differs from the Setting
84
Acceleration/Deceleration Is Not Smooth
84
Motor Current Is Large
84
Speed Does Not Increase
84
Speed Varies During Operation
84
Operation Mode Is Not Changed Properly
85
Operation Panel (FR-DU07) Display Is Not Operating
85
POWER Lamp Is Not Lit
85
Parameter Write Cannot be Performed
85
Precautions for Maintenance and Inspection
86
Inspection Item
86
Daily Inspection
86
Periodic Inspection
86
Daily and Periodic Inspection
87
Display of the Life of the Inverter Parts
88
Checking the Inverter and Converter Modules
89
Cleaning
90
Replacement of Parts
90
Inverter Replacement
94
Measurement of Main Circuit Voltages, Currents and Powers
95
Insulation Resistance Test Using Megger
95
Pressure Test
95
Measurement of Voltages and Currents
95
Specifications
97
Rating
97
Common Specifications
98
Outline Dimension Drawings
100
Inverter Outline Dimension Drawings
100
Operation Panel (FR-DU07) Outline Dimension Drawings
107
Parameter Unit (FR-PU04) Outline Dimension Drawings
107
Heatsink Protrusion Attachment Procedure
108
When Using a Heatsink Protrusion Attachment (FR-A7CN)
108
Protrusion of Heatsink of the FR-F740-04320 or more
108
Appendices
111
Appendix 1 List of Parameters Classified by Purpose of Use
111
Appendix 2 Extended Parameters
113
Appendix 2-1Used to Display the Extended Parameters
113
Appendix 2-2Extended Parameter List
114
Appendix 3For Customers Who Have Replaced the Older Model with this Inverter
137
Appendix 3-1Replacement of the FR-F500 Series
137
Appendix 3-2Replacement of the FR-A100 <EXCELENT> Series
138
Appendix 4 Instructions for UL and Cul
139
Appendix 5 Instructions for Compliance with the European Directives
141
Advertisement
Mitsubishi Electric FR-F740-02600-EC Installation Manuallines (36 pages)
FR-F700 Series
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 1.43 MB
Table of Contents
Table of Contents
1
Installation and Instructions
7
Outline Drawing
9
Main Circuit
10
Wiring
10
Terminal Layout and Wiring
11
Cable Size
13
Control Circuit Terminals
16
Precautions for Use of the Inverter
17
Failsafe of the System Which Uses the Inverter
19
Parameter List
20
Parameter
20
Troubleshooting
27
Reset Method of Protective Function
28
List of Alarm Display
29
Appendix
30
Aappendix
30
Mitsubishi Electric FR-F740-02600-EC Installation Manuallines (13 pages)
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 8.97 MB
Table of Contents
Introduction
2
Outline
2
Product Check
4
Setting up
6
Advertisement
Related Products
Mitsubishi Electric FR-F740-02160-NA
Mitsubishi Electric FR-F740-02600-NA
Mitsubishi Electric FR-F 740-02160-EC
Mitsubishi Electric FR-F 740-02600-EC
Mitsubishi Electric FR-F740-00023
Mitsubishi Electric FR-F740-00038-NA
Mitsubishi Electric FR-F740-00470-NA
Mitsubishi Electric FR-F 740-05470-EC
Mitsubishi Electric FR-F 740-03610-EC
Mitsubishi Electric FR-F 740-04320-EC
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL