Server
EXP287A
NEC EXP287A Manuals
Manuals and User Guides for NEC EXP287A. We have
3
NEC EXP287A manuals available for free PDF download: Maintenance Manual, User Manual
NEC EXP287A Maintenance Manual (160 pages)
Express Server
Brand:
NEC
| Category:
Server
| Size: 2.85 MB
Table of Contents
Documents for this Product
2
Table of Contents
3
Contents
3
Notations Used in this Document
6
Notations Used in the Text
6
Optical Disk Drive
6
Hard Disk Drive
6
Removable Media
6
Abbreviations of Operating Systems (Windows)
7
License Notification
8
Trademarks
8
Regulatory Notices
9
Warnings and Additions to this Document
12
Latest Editions
12
Chapter 1 Maintenance
13
Transfer, Movement, and Disposal
14
Transfer to a Third Party
14
Disposal of the Server and Consumables
15
Regarding the Transportation of this Server
15
Moving and Storage
15
Daily Maintenance
17
Checking and Applying Updates
17
Checking Alerts
17
Status Indicator Leds
18
Backup
18
Cleaning
18
Cleaning the Server
19
Cleaning the Tape Drive
19
Cleaning the Keyboard and Mouse
19
User Support
20
Maintenance Services
20
Before Asking for Repair
20
Collecting Failure Information
21
Collecting Event Logs
21
Windows Server 2012
21
Windows Server 2008 R2 / Windows Server 2008
23
Collecting Configuration Information
24
Windows Server 2012
24
Windows Server 2008 R2/ Windows Server 2008
25
Collecting User-Mode Process Dump
25
Collecting Memory Dump
25
Troubleshooting
26
Problem of Powering on
26
Problem of Starting EXPRESSBUILDER
28
Problem of Installing os
29
Problem of Starting os
31
Problem of Windows STOP Error
32
Problem of Operating a RAID System
33
Problem of Using Internal Devices and Other Hardware
35
Problem of os
37
Problem of Stating EXPRESSBUILDER on Windows
38
Problem of Bundled Software
38
Problem of Optical Disk Drive
39
Problem of Powering off
39
Windows System Recovery
40
Recovery of Windows Server 2012
40
Recovery of Windows Server 2008 R2 and Windows Server 2008
40
Resetting and Clearing the Server
41
Software Reset
41
BMC Reset
41
Forced Shutdown
43
Clearing BIOS Settings (CMOS Memory)
45
System Diagnostics
48
Test Items
48
Startup and Exit of System Diagnostics
48
Offline Tools
51
Starting Offline Tools
51
Features of Offline Tools
52
Console-Less Feature
53
How to Remotely Control
53
Preparation
53
Chapter 2 Useful Features
54
System BIOS
55
Starting SETUP
55
Parameters
55
Main
55
Advanced
57
Security
72
Server
76
Boot
81
Save & Exit
83
BMC Configuration
84
Starting BMC Configuration
84
Main Menu of BMC Configuration
85
Setting BMC Configuration
86
Network
87
User Management
89
Mail Alert
91
SNMP Alert
93
System Operation
94
Eco
95
Miscellaneous
97
Clear BMC Configuration
97
Resetting BMC
98
Initializing BMC
98
Flash FDD
99
Precautions
99
Compensation for Recorded Data
99
Handling Flash FDD
99
Precautions When Using EXPRESSBUILDER
99
Power Control Feature
100
Supported os
100
Notes on Using Windows Server 2008
100
RAID System Configuration
101
Running the LSI Software RAID Configuration Utility
101
Exiting the LSI Software RAID Configuration Utility
102
Menu Tree
103
Using LSI Software RAID Configuration Utility
105
Creating and Adding a Configuration
105
Executing Rebuilding Manually
110
Setting a Hot Spare
111
Executing the Consistency Check
113
Other Features
114
LSI Software RAID Configuration Utility and Universal RAID Utility
115
Webbios and Universal RAID Utility
117
Details of EXPRESSBUILDER
119
Starting EXPRESSBUILDER
119
Menus of EXPRESSBUILDER
120
Utilities Provided by EXPRESSBUILDER
123
EXPRESSSCOPE Engine 3
124
Nec Esmpro
125
NEC ESMPRO Agent (for Windows)
125
NEC ESMPRO Manager
126
NEC ESMPRO Agent Extension
127
BMC Configuration
127
NEC Expressupdate Agent
127
NEC Product Info Collection Utility
128
Usage
128
Universal RAID Utility
129
Easy Configuration Feature
129
Creating Logical Drive of RAID 6
129
Express Report Service / Express Report Service(HTTPS)
130
Express Report Service(MG)
131
Chapter 3 Appendix
132
POST Error Message
133
List of Windows Event Logs
145
Accessing Data for Electric Power, Temperature, and Processor Utilization
154
Windows
154
Power Consumption
154
Intake Air Temperature
155
Processor Utilization
158
Linux
159
Power Consumption
159
Intake Air Temperature
159
Processor Utilization
160
Advertisement
NEC EXP287A Maintenance Manual (164 pages)
Brand:
NEC
| Category:
Server
| Size: 12.26 MB
Table of Contents
Table of Contents
3
本文档中使用的提示标志
7
文本中的提示标志
7
选项磁盘驱动器
7
硬盘驱动器
7
可移动介质
7
操作系统的缩写(Windows)
8
版权注意事项
9
合规性注意事项
10
对本文档的警告及追述
13
最新版本
13
第 1 章 维护
14
转让、移动及保管服务器
15
转让给第三方
15
服务器和耗材的废弃处理
16
关于本服务器的运输
16
移动及保管
16
日常维护
18
查看并应用更新
18
查看警报消息
18
检查状态指示灯
19
清洁服务器
20
清洁磁带驱动器
20
清洁键盘及鼠标
20
用户支持
21
维护服务
21
报修前
21
收集故障信息
22
收集事件日志
22
Windows Server 2012 R2/Windows Server 2012
22
Windows Server 2008 R2 / Windows Server 2008
24
收集配置信息
25
Windows Server 2012 R2/Windows Server 2012
25
Windows Server 2008 R2/ Windows Server 2008
26
收集用户模式进程内存转储
26
收集内存转储
26
故障排除
27
开机时的故障
27
启动 Expressbuilder 时的故障
29
安装 os 时的故障
30
启动操作系统时的故障
33
Windows STOP Error 的故障
35
操作 Raid 系统时的故障
36
使用内部设备和其他硬件时的故障
39
操作系统的故障
40
在 Windows 中启动了 EXPRESSBUILDER 时的故障
41
附带的软件的问题
41
光盘驱动器的故障
42
关闭电源时的故障
42
Windows 系统恢复
43
恢复 Windows Server 2012 R2 和 Windows Server 2012
43
恢复 Windows Server 2008 R2 和 Windows Server 2008
43
复位和清理服务器
44
软件重置
44
Bmc 重置
44
强制关机
46
清除 Bios 设置(Cmos 内存)
48
系统诊断
51
系统诊断的用法
51
脱机工具
53
启动脱机工具
53
脱机工具的功能
54
省略控制台功能
55
如何进行远程控制
55
准备工作
55
第 2 章 便捷功能
56
系统 Bios
57
启动 Setup
57
Main
57
Advanced
59
Security
74
Server
79
Boot
84
Save & Exit
86
BMC Configuration
87
启动 BMC Configuration
87
BMC Configuration 的主菜单
88
设置 BMC Configuration
89
Network
90
User Management
92
Mail Alert
94
SNMP Alert
96
System Operation
97
Eco
98
清除 BMC Configuration
100
重置 Bmc
101
初始化 Bmc
101
Flash FDD
102
注意事项
102
被记录数据的赔偿
102
操作 Flash FDD
102
使用 Expressbuilder 时的注意事项
102
电源控制功能
103
支持的 os
103
使用 Windows Server 2008 时的提示
103
Raid 系统配置
104
运行 LSI Software RAID Configuration Utility
104
退出 LSI Software RAID Configuration Utility
105
菜单树
106
使用 LSI Software RAID Configuration Utility
108
创建和添加配置
108
手动执行重建
113
设置热备份
114
执行一致性检查
116
其他功能
117
LSI Software RAID Configuration Utility 和 Universal RAID Utility
118
Webbios 和 Universal RAID Utility
120
Expressbuilder 的详细信息
122
使用 Expressbuilder
122
Expressbuilder 的菜单
123
Expressbuilder 的实用程序
126
EXPRESSSCOPE Engine 3
127
Nec Esmpro
128
NEC ESMPRO Agent (for Windows)
128
NEC ESMPRO Manager
128
NEC ESMPRO Agent Extension
128
Bmc 配置
128
NEC Expressupdate Agent
128
Nec 产品信息收集实用程序
129
Universal RAID Utility
130
简易配置功能
130
创建 Raid 6 的逻辑驱动器
130
Express Report Service/Express Report Service(HTTPS)
131
Express Report Service(MG)
132
第 3 章 附录
133
Post 错误消息
134
Windows 事件日志列表
145
获取关于电源、温度和处理器使用率的数据
158
Windows
158
耗电量
158
进气温度
159
处理器利用率
162
Linux
163
耗电量
163
进气温度
163
处理器使用率
164
NEC EXP287A User Manual (133 pages)
Brand:
NEC
| Category:
Server
| Size: 4.22 MB
Table of Contents
Documents for this Product
2
Contents
3
Table of Contents
3
Hard Disk Drive
7
Notations Used in the Text
7
Notations Used in this Document
7
Optical Disk Drive
7
Removable Media
7
Abbreviations of Operating Systems
8
License Notification
9
Trademarks
9
Regulatory Notices
10
Latest Editions
13
Warnings and Additions to this Document
13
Precautions for Use (be Sure to Read)
14
Safety Precautions
14
Symbols Used in this Document and on Warning Labels
15
General
16
Safety Notes
16
Power Supply and Power Cord Use
17
Installation, Relocation, Storage, and Connection
19
Cleaning and Working with Internal Devices
20
During Operation
21
Warning Labels
22
Handling Precautions
23
Anti-Static Measures
24
Chapter 1 General Description
26
Introduction
27
Accessories
28
Standard Features
29
Management Features
31
Firmware and Software Version Management
32
Names and Functions of Parts
33
Front of the Server
33
Rear View
34
Internal View
35
Motherboard
37
Status Indicators
38
Power Led
38
Status Led ( )
39
Disk Access LED
40
Optical Disk Access LED
40
Disk LED
40
Link/Act Led ( 1, 2, M)
41
Speed Led ( 1, 2, M)
41
Ac Power Led
41
Chapter 2 Preparations
42
Installing Internal Optional Devices
43
Safety Precautions
43
Anti-Static Measures
44
Overview of Installation and Removal
45
Removing the Side Cover
46
Removing the Front Bezel
47
Internal Flash Memory
48
Installation
48
Removal
48
TPM Kit
49
Installation
49
DIMM
50
Maximum Supported Memory Size
51
Installation Order
51
Installation
52
Removal
53
Use of Internal Hard Disk Drives in the RAID System
54
Notes on Setting up a RAID System
58
Extra Battery for RAID Controller
60
Handling Precautions
60
Installing N8103-155 Extra Battery
60
Removal
64
Installing the Flash Backup Unit that Comes with N8103-168
64
Removal
67
PCI Card
68
Notes
69
List of Optional Devices and Installation Slots
70
Installation
72
Configuration after Installing
73
Removal
74
Installing the N8117-01A Extra RS-232C Connector Kit
74
HDD Cages
76
Installing a 3.5-Inch Fixed HDD Cage and Hard Disk Drives
77
Removing the 3.5-Inch Fixed Hard Disk Drives
79
Removing the 3.5-Inch Fixed HDD Cage
80
Installing the 3.5-Inch HDD Cage and Hard Disk Drives
81
Removing the 3.5-Inch Hard Disk Drives
84
Removing the 3.5-Inch HDD Cage
85
Installing the 2.5-Inch HDD Cage and Hard Disk Drives
86
Removing the 2.5-Inch Hard Disk Drives
89
Removing the 2.5-Inch HDD Cage
90
Optical Disk Drive
91
Replacing Drives
91
Removal
92
Backup Devices
93
Installation
94
Removal
94
Power Supply (EXP288A)
95
Cold Redundant Feature
95
Installing a Redundant Power Supply
95
Replacing or Removing a Faulty Redundant Power Supply
97
Connecting Cables
98
Internal Interface Cables
98
Power Cables
104
Attaching the Front Bezel
108
Installing the Side Cover
109
Installation and Connection
110
Installation
110
Preparation for Installation
112
Connection
113
Interface Cables
114
Power Cord
115
Chapter 3 Setup
116
Turning on the Server
117
Post
118
POST Sequence
118
POST Error Messages
119
System BIOS Setup
120
Overview
120
Starting SETUP Utility
120
Description on On-Screen Items and Key Usage
121
Cases that Require Setting Changes
123
Expressscope Engine 3
124
Overview
124
EXPRESSSCOPE ENGINE 3 Network Configuration
125
Expressbuilder
127
Features of EXPRESSBUILDER
127
Usage of EXPRESSBUILDER
127
Installing Software Components
128
Turning off the Server
129
Chapter 4 Appendix
130
Specifications
131
Express5800/T110G-E (EXP287A)
131
Express5800/T110G-E (EXP288A)
132
Interrupt Lines
133
Advertisement
Advertisement
Related Products
NEC EXP200
NEC EXP260A
NEC EXP292
NEC EXP285A
NEC EXP281A
NEC EXP291
NEC EXP283A
NEC EXP284A
NEC EXP288A
NEC Express5800/R120i-1M
NEC Categories
Monitor
Projector
Server
Telephone
Computer Hardware
More NEC Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL