Sign In
Upload
Manuals
Brands
Panasonic Manuals
Air Conditioner
S-60PE1R5B
Panasonic S-60PE1R5B Manuals
Manuals and User Guides for Panasonic S-60PE1R5B. We have
2
Panasonic S-60PE1R5B manuals available for free PDF download: Technical Data & Service Manual, Operating Instructions Manual
Panasonic S-60PE1R5B Technical Data & Service Manual (260 pages)
Brand:
Panasonic
| Category:
Air Conditioner
| Size: 41.48 MB
Table of Contents
Product View
1
Safety Information
2
Check of Density Limit
6
Table of Contents
7
Specifications
8
Dimensional Data
43
Dimensional Data
44
Refrigerant Flow Diagram
52
Operating Range
53
Capacity Correction Graph According to Temperature Condition
54
1-1. Unit Specifications
59
Noise Criterion Curves
59
4-Way Cassette Type
59
Ducted Type
60
Ceiling Type
61
Low Silhouette Ducted Type
63
1-5. Capacity Correction Graph According to Temperature Condition
64
1-4. Operating Range
64
Wall Mounted Type
64
Noise Criterion Curves
64
Indoor Fan Performance
68
Type E1
68
External Static Pressure Setting
69
Flow of External Static Pressure
69
Type F1
69
How to Set on PC Board
70
Selection of Connected Short-Circuit Pins
70
Operating the High-Spec Wired Remote Controller
71
How to Set the External Static Pressure
71
Auto External Static Pressure Setting Operation
72
Operating the Timer Remote Controller
73
Auto Airflowvolume Control Operations
73
External Static Pressure Setting-Check Operation
73
Airflow Distance Chart
75
External Air Intake Coupling
80
Intaking Fresh Air of 4-Way Cassette Type
80
Mixed Air
80
Precautions Regarding External Air Intake
80
External Air Intake Volume & Resistance Within Unit
81
Operation Noise Characteristics
81
The Amount of External Air Intake that Is Possible to Feed
82
Electrical Wiring
84
General Precautions on Wiring
84
1-11. Installation Instructions
85
Outdoor Unit
85
Indoor Unit
85
How to Connect Wiring to the Terminal
87
Assembling Parts for Outdoor Unit Cover
87
Wiring Procedure
91
Connection for Demand and Forced Stop
94
When Connection to the Forced Stop Input
94
When Connecting the Demand Controller Input
95
When Connecting to the Next System Unit
95
Recommended Wire Length and Wire Diameter for Power Supply System
85
Wiring System Diagrams
85
Indoor Unit
97
Type U2
98
Type E1
99
Examples of Shield Wires
100
How to Carry out Power Supply Wiring
101
Type F1
101
Type K2
101
Installation Instructions
102
Selecting the Installation Site
102
Air-Discharge Chamber for Top Discharge
106
Countermeasures against Snow and Wind
106
Installing the Unit in Heavy Snow Areas
106
Tubing Size
107
Precautions for Installation Using New Refrigerant
109
Important Information Regarding the Refrigerant Used
110
Drainage Work
111
How to Install the Outdoor Unit
111
Caution before Connecting Tubes Tightly
112
Cautions During Brazing
112
How to Process Tubing
112
Use of the Flaring Method
112
Connecting Tubing between Indoor and Outdoor Units
113
Insulating the Refrigerant Tubing
113
Finishing the Installation
114
Taping the Tubes
114
Air Purging with a Vacuum Pump (for Test Run)
115
Leak Test
115
Leak Test, Evacuation and Additional Refrigerant Charge
115
Charging Additional Refrigerant
116
Evacuation
116
Finishing the Job
116
Precautions for Using R32 Refrigerant
117
Checks to Electrical Devices
119
Decommissioning
121
Recovery
122
Type K2
123
Accessories Supplied with Outdoor Unit
124
Select the Outdoor Unit Installation Location
124
Selecting the Location for Installation Service
125
Refrigerant Installation
127
Transport and Install the Outdoor Unit
127
Precautions for Connecting the Pipes
128
Precautions for Flare Nut Installation
128
Precautions for Insulation Installation
128
Precautions When Operating the 3-Way Valve for Piping Installation
128
Leak Test and Evacuation
129
Regarding Refrigerant Filling
129
Selecting the Installation Site - Indoor Unit
130
How to Install the Indoor Unit
131
Suspending the Indoor Unit
131
Placing the Unit Inside the Ceiling
132
Installing the Drain Pipe
133
Limitations of Drain Hose Connection
133
Limitations of Drain Pipe Connection
133
Limitations of Raising the Drain Pipe Connection
133
Checking the Drainage
135
Connecting the Refrigerant Tubing
136
Flaring Procedure with a Flare Tool
136
Taping the Flare Nuts
137
Accessories Supplied with the Indoor Unit
138
How to Install the Timer Remote Controller/Wired Remote Controller
138
How to Install the Ceiling Panel
139
How to Install the Panel for Cassette
139
Preparation for Panel for Cassette Installation
139
Installing the Panel for Cassette
140
Removing the Corner Cover
140
Attaching the Air-Intake Grille
141
Attaching the Corner Cover
141
Wiring the Panel for Cassette
141
Checking after Installation
142
Selecting DC Fan Motor Tap (4-Way Cassette)
142
Setting the Flap Separately
143
Criteria for Human Detection Area
146
ECONAVI System Setting
154
ECONAVI Test Operation
155
External Device Interlock
156
Checklist after Installation Work
157
Air Filter
158
Care and Cleaning
158
Troubleshooting
159
Check before Requiring Services
160
Should the Power Fail While the Unit Is Running
160
Tips for Energy Saving
160
Refrigerant Information
161
Removal and Evacuation
162
Air Intake Chamber
163
Option Parts
163
Selecting the DC Fan Motor Taps
165
Air-Flow Blocking Kit
166
Air Outlet Blocking Patterns
167
Procedure for Attaching the Parts
169
Thermal Insulation Kit
169
Parts Installed on the Indoor Unit
170
Parts Mounted on Ceiling Panels
171
Required Minimum Space for Installation and Service (Indoor Unit)
173
Connecting Duct to Indoor Unit
175
Tubing Insulation
177
Troubleshooting - Indoor Unit
180
Final Procedure
191
Type of Copper Tube and Insulation Material
192
Low Silhouette Ducted Type Indoor Unit - Installation
200
Installing the Drain Pipe
202
Connecting Duct to Air Intake Port Side
203
How to Make a Hole
214
Install the Installation Plate on the Wall
215
Left-Rear Side, Left Side, Left-Bottom Side Tubing
216
Right-Rear Side, Right Side, Right-Bottom Side Tubing
216
To Mount and Unmount Indoor Unit
217
Before Switching on
222
Precautions on Test Run
222
Type T2
101
Connection for Demand and Forced Stop
227
Capacity Table
231
Cooling Capacity Performance Data
231
1 Cooling Capacity Performance Data
233
2 Heating Capacity Performance Data
236
Test Run
242
U-100Pz2R5, U-125Pz2R5, U-140Pz2R5
242
U-100Pz2R8, U-125Pz2R8, U-140Pz2R8
242
U-60Pz2R5, U-71Pz2R5
243
Preparing for Test Run
243
Test Run Procedure
244
Caution
244
Items to Check before the Test Run
244
Test Run Using the Remote Controller
245
Precautions
246
Setting the Outdoor Unit System Addresses
247
Link Wiring Sample
247
Auto Address Setting Using the Remote Controller
248
Display During Auto Address Setting
249
Display of Remote Controller
249
Indicating (Marking) the Indoor and Outdoor Unit Combination Number
250
Table of Self-Diagnostic Functions and Corrections
251
Auto Address Setting from the Outdoor Unit
253
Test Run Using the Indicator of the Indoor Unit (Type K2)
253
Caution for Pump down
254
How to Perform Pump-Down (Refrigerant Recovery) Properly
254
Safe Servicing
254
How to Install Wireless Remote Controller
254
Removal and Evacuation
255
Charging Procedures
256
Decommissioning
256
Recovery
257
Precautions Regarding Test Run
258
U-100Pz2R5, U-125Pz2R5, U-140Pz2R5 U-100Pz2R8, U-125Pz2R8, U-140Pz2R8
258
Checks after Installation Have Completed
259
Regarding Delivery to the Customer
259
Advertisement
Panasonic S-60PE1R5B Operating Instructions Manual (12 pages)
Brand:
Panasonic
| Category:
Air Conditioner
| Size: 0.99 MB
Table of Contents
Table of Contents
2
Safety Precautions
2
Precautions for Use
5
Names of Parts
6
Maintenance
7
Operation Mechanism
7
Troubleshooting
8
Before Requesting Services
9
Advertisement
Related Products
Panasonic S-60PE1R5
Panasonic S-60PE3R
Panasonic S-60PT2R5
PANASONIC S-60PK1E5
PANASONIC S-60PT1E5
Panasonic S-60PF1E5A
Panasonic S-60PT2E5A
Panasonic S-60PT2E5
Panasonic S-60PT2R5A
Panasonic S-60PU1R5A
Panasonic Categories
Camcorder
Air Conditioner
TV
Digital Camera
Cordless Telephone
More Panasonic Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL