Sign In
Upload
Manuals
Brands
Siemens Manuals
Control Unit
LMV51.000B2
Siemens LMV51.000B2 Manuals
Manuals and User Guides for Siemens LMV51.000B2. We have
1
Siemens LMV51.000B2 manual available for free PDF download: Basic Documentation
Siemens LMV51.000B2 Basic Documentation (299 pages)
Burner Control with integrated Fuel / Air Ratio Control and Load Control, Load Control including O2 Trim Control for Forced Draft Burners
Brand:
Siemens
| Category:
Control Unit
| Size: 5.36 MB
Table of Contents
Table of Contents
4
Lmv51.140B1
23
Lmv51.200A1
23
Lmv51.200A2
23
Lmv52.200A1
23
Lmv52.200A2
23
Lmv52.240A1
23
Lmv52.240A2
23
Block Diagram Inputs / Outputs
24
Block Diagram (Cont'D)
25
Block Diagram (Cont'D)
26
Fuel Train Applications (Examples)
27
Direct Gas Ignition
27
Gas Pilot Ignition 1
27
Gas Pilot Ignition 2
27
Fuel Valve Control Program
27
Fuel Train Applications (Cont'D)
28
Direct Ignition with Light Oil, Multistage
28
Direct Ignition with Light Oil, Modulating
29
Fuel Valve Control Program
29
Direct Ignition with Heavy Oil, Multistage
30
Direct Ignition with Heavy Oil, Modulating
30
Fuel Valve Control Program
31
Dual-Fuel Burner Gas / Light Oil with Gas Pilot Ignition
32
Fuel Valve Control Program
32
Dual-Fuel Burner Gas / Heavy Oil with Gas Pilot Ignition
33
Fuel Valve Control Program
33
Burner Control
34
Description of Inputs and Outputs
34
Flame Signal Input and Flame Detector X10-01 and X10-03
34
Self-Test Function LMV5
34
Separate Flame Supervision, Only with LMV52
34
Application Example
35
Implementation
35
Technical Data, Flame Supervision
35
QRI (Suited for Continuous Operation)
35
Connection Diagram
35
IONIZATION (Suited for Continuous Operation)
36
Qrb
36
Digital Inputs
37
Safety Loop X3-04
37
Flange X3-03
37
Inputs for External Controller (ON/OFF) X5-03
37
Inputs (on / off or STAGE2 / STAGE3)
38
X5-03
38
Air Pressure Switch (APS) X3-02
38
Pressure Switch-VP-Gas / LT or Closed Position Indicator (CPI) X9-03
39
Pressure Switch-Min-Gas, Start Release Gas (Psmin-Gas) X9-03
39
Start Release Gas X7-03 (Only with LMV52
40
Pressure Switch-Max-Gas, (Psmax-Gas) X9-03
40
Pressure Switch-Min-Oil (Psmin-Oil) X5-01
40
Pressure Switch-Max-Oil (Psmax-Oil) X5-02
41
Start Release-Oil (START) X6-01
41
Direct Heavy Oil Start (HO-START) X6-01
41
Fan Contactor Contact (FCC) or FGR-PS X4-01
41
Digital Outputs
42
Alarm Output, Type No-SI X3-01
42
Output Fan, Type No-SI X3-01
42
Output Ignition, Type si (IGNITION) X4-02
42
Outputs Valves-Oil , Type si (V
42
Outputs Valves -Gas, Type si (V
42
Output Oil Pump / Magnetic Clutch, Type No-SI X6-02
43
(Start) X4-03
43
Program Sequence
44
Parameters
44
Time Parameters
44
Gas Valve Proving
45
Recommendation
45
Determination of VP Leakage Rate
46
Special Functions During the Program Sequence
47
Lockout Phase (Phase 00)
47
Safety Phase (Phase 01)
47
Reset / Manual Lockout
47
Characteristics
47
Signaling Star Preventions
48
Forced Intermittent Operation
48
Program Stop Function
48
Gas Shortage Program
49
Sequence Diagram
49
Part Load Shutdown
49
Normal / Direct Start
50
Continuous Fan Operation
50
Continuous Pilot Control (Only LMV52)
50
Response to Extraneous Light in Standby
50
Selection of Fuel
51
Selection of Fuel with the Fuel Selector on the LMV5
51
Selection of Fuel on the AZL5
51
Selection of Fuel Via BACS
51
Fuel Changeover
51
Sequence Diagrams
52
Direct Gas Ignition
52
Gas Pilot Ignition 1
53
Gas Pilot Ignition 2
54
Light Oil Direct Ignition
55
Heavy Oil Direct Ignition
56
Light Oil with Gas Pilot Ignition
57
Heavy Oil with Gas Pilot Ignition
58
Legend to the Sequence Diagrams
59
Fuel / Air Ratio Control (FARC)
60
General
60
Basic Documentation LMV5
60
Program Sequence
60
Standby
60
Preventilation
60
Ignition
61
Traveling to the Operating Position
61
Operation
61
End of Operating Position
61
Postpurging
62
Actuator Speed Outside Normal Operation
62
Operating Position
62
Modulating
62
Multistage Operation
63
Position Check
64
Dynamic Safety Time Ratio Control
64
Outside the Operating Position
66
Operating Position Modulating
66
Operating Position Multistage
66
Special Features
66
Program Stop
66
Direction of Rotation of Actuators
66
Limitation of the Load Range
67
Activation of Actuators / VSD
68
Lmv51
68
Lmv52
68
Number of Fuel Actuators
68
Traveling Times
68
Shutdown Behavior
68
Overload Protection of Actuators
68
Curve Adjustment
68
Temperature or Pressure Controller (Internal Load Controller LC)
69
General
69
Connection Diagram
69
Operating Modes with the Load Controller
69
Operating Mode 1 (Extlc X5-03)
70
Operating Mode 2 (Intlc)
71
Operating Mode 3 (Int LC Bus)
71
Operating Mode 4 (Int LC X62)
72
Operating Mode 5 (Ext LC X62)
72
Operating Mode 6 (Ext LC Bus)
73
Operating Mode Changeover to Internal Load Controller
73
Control (Characteristics)
74
Operating Mode
74
Integrated 2-Position Controller (C = on / OFF)
74
General
74
Switching Differentials
74
Modulating Control
75
General
75
Function Diagrams
75
Control Parameters
75
Manual Setting of the Control Parameters
75
Self-Setting of Control Parameters (Adaption)
76
Adaption Sequence
76
Checking the Control Parameters
77
Example
77
Settling of the Manipulated Variable
78
Principle
78
Description (Graph)
78
Multistage Control
79
General
79
Load-Dependent Activation of the Higher Burner Stages
79
Function Diagrams
80
Actual Values (X)
81
Input 1, TEMP, Pt100 Sensor (DIN) X60
81
Input 2: TEMP. / PRESS INPUT, DC 0
81
X61
81
Measuring Range Temperature (Can be Parameterized)
81
Measuring Range Pressure (Can be Parameterized)
81
Input 4: TEMP, Pt1000 / LG-Ni 1000 X60
82
Setpoints (W)
83
Internal Setpoint
83
Input 3: SET POINT INPUT X62
83
External Predefined Setpoint
83
External Predefined Load
83
External Predefined Load, Modulating
83
External Predefined Load, Multistage
84
External Setpoint Changeover
84
External Setpoints or Predefined Load Via Digital Modbus / E-Bus Interface
84
Integrated Temperature Limiter Function
85
TL Within the Scope of TRD
85
TL with External Predefined Load
85
Requirements Placed on Sensor and Protection Pocket
85
Cold Start Thermal Shock Protection (CSTP)
86
CSTP - Modulating Operation
86
CSTP - Multistage Operation
87
CSTP with Temperature Sensor in Pressure Plants
87
Output
88
Output 4
88
Output, Modulating
88
Output, Multistage
88
Multiboiler Plants
88
Multiboiler Plants by Means of an Analog Input
88
Multiboiler Plants by Means of a Digital Interface
88
Display and Operating Unit AZL5
89
Assignment of AZL5
90
Connecting Cable to the E-Bus Adapter
91
Connecting Cable to the PC
91
Ports of the AZL5
92
Port for the PC
93
Connection to Superposed Systems
94
General Information and BACS Functions
94
Reading Ebus-Specific
94
Data
94
Writing Parameters
95
List of Supported Ebus Commands
95
Display and Settings
96
Menu Structure
96
Displays
97
Display (Cont'D)
98
Displays (Cont'D)
99
Lockout and Error Messages
100
Lockout and Error Messages (Cont'D)
101
Standard Parameterizations (Incl. Entry of Password)
102
Entry of Password (PW)
103
Start Display
103
First Submenu Level
104
Second Submenu Level
104
Third Submenu Level
104
Fourth Submenu Level
104
Addressing the Actuators (Function Assignment)
105
Direction of Rotation
106
Reset
106
Operational Status Indication by LED on the Actuator
106
Power Is Fed to Unaddressed Actuator
106
Button for Addressing Is Pressed (Display During Addressing Procedure)
106
Addressing Completed, Normal Operation of Actuator
106
Special Function Curve Settings FARC
107
Special Function Adaption LC
117
Burner Identification (Burner ID)
119
Makeup of Burner ID
119
Languages
119
Real Time Clock and Calendar
119
S / W Changeover
119
Backup
119
Type of Battery
119
Adjustment of Contrast (Display)
120
Shutdown Function
120
Quick Access Normal Operation
120
Safety Check Function
121
Loss-Of-Flame Test
121
SLT Test
121
Menu and Parameter Lists
121
Azl5
121
Commissioning Instructions for the LMV5
150
Practice-Oriented Setting Instructions for the System Configuration, the Burner Control, and the Electronic Fuel / Air Ratio Control System
150
Basic Configuration
150
Parameterizing the Burner Identification (Burner ID)
150
Selecting the Fuel Trains
150
Checking the Inputs / Outputs While Taking into Account the Burner
150
Setting Gas Valve Proving
151
Addressing the Actuators
151
Selecting the Actuator's Direction of Rotation
152
Configuration of VSD (Only Lmv5X.2
152
Lmv52
152
Setting the Load Controller (Option)
153
Selecting a Temperature or Pressure Sensor
153
Settings for Gas-Fired Operation
154
Activating Program Stops in Different Program Phases
154
Checking and Presetting the Actuators Positions for Gas Ignition
154
Manual Startup
154
Actuator Positions During the Prepurge Time
155
Note
155
Ignition Positions
155
Setting the Curve
156
First Setting
156
Changing an Existing Curve
157
Creating a New Curvepoint
157
Loadlimits
157
Shutdown
157
Settings for Multistage Firing on Oil
158
Fuel Changeover for Firing on Oil
158
Changing the Burner Operating Mode from Modulating to Multistage (Only When Firing on Oil)
158
Activating the Program Stops in the Different Program Phases
158
Checking and Presetting the Ignition Positions for Firing on Oil
159
Manual Startup
159
Actuator Positions During the Prepurge Time
159
Note
159
Ignition Positions
160
Setting the Burner Stages
161
Shutdown
162
Extra Functions of the LMV5
163
Valve Proving (Leakage Test LT)
163
Example 1 (Calculation of Test Time)
164
Example 2 (Determination of Detectable Leakage Rate)
164
Configuration of the Load Controller
165
Selection of Operating Mode
165
Control Parameters of the Load Controller
166
Selection of the Standard Parameter Set
166
Individual Setting of the PID Parameters
166
Automatic Adaption
166
Temperature Limiter Function
167
Boiler Setpoints W1 and W2
167
2-Position Controller (C = on / OFF)
168
Diagram
168
Cold Start Thermal Shock Protection (CSTP)
168
Description
168
Connection Terminals / Coding of Connectors
170
Connection Terminals of the Lmv51.000X1 / Lmv51.040X1
170
Connection Terminals of the Lmv51.000X2
171
Connection Terminals of the Lmv51.100X1 / Lmv51.140X1
172
Connection Terminals of the Lmv51.100X2
173
Connection Terminals of the Lmv51.200X1
174
Connection Terminals of the Lmv51.200X2
175
Connection Terminals of the LMV52.200A2 / LMV52.240A2
176
Connection Terminals of the LMV52.200A1 / LMV52.240A1
177
Coding of Connectors
178
Agg5.720
179
Agg5.721
180
Description of the Connection Terminals (AC 120 V)
181
Description of the Connection Terminals (AC 230 V)
186
Mounting, Electrical Installation and Service
191
Installation
191
Electrical Connections and Wiring
191
Connection of LMV5
191
Power Supply to the LMV5
192
Determination of the Maximum Cable Length
195
Types of Cable
196
Suppliers of Other Accessory Items
197
Mounting Rail Adapter Type: USA 10 / 4,6
197
E-Bus / PC Adapter Part No. 230 437
197
Duties of the Authorized Inspector
198
Lmv51
198
In Addition with LMV52
198
Correct Parameterization of the System
198
Fuel / Air Ratio Control System
199
Burner Control Section
199
O2 Trim Control (Only with LMV52
200
General
200
Technical Data
201
Lmv5
201
Basic Unit LMV5
201
Environmental Conditions LMV5
201
Azl
201
Environmental Conditions AZL5
201
Lmv5
202
Types of Cable
202
Loads on Terminals, Cable Lengths and Cross-Sectional Areas
203
Loads on Terminals
203
General Data
203
Mains Supply
203
Undervoltage
203
Oil Pump / Magnetic Clutch
203
APS Test Valve
203
Status Inputs (CFN)
203
Load on Terminals "Outputs
203
Total Load on Contacts
203
Load on Individual Contacts
204
Fan Motor Contactor
204
Alarm Output
204
Ignition Transformer
204
Fuel Valves (Gas)
204
Fuel Valves (Oil)
204
Cable Lengths
204
Cross-Sectional Areas
204
Fuses Used in the LMV5
204
Dimensions
205
Lmv5
205
Azl5
205
Addendum 1: List of Fault Status Messages of LMV5
206
Addendum 2: Connection Diagram
251
Addendum 3: Variable Speed Drive (VSD) Module
252
General
252
Basic Diagram
252
Lmv51
252
Lmv52
252
VSD Module
253
General
253
Inputs / Outputs
253
Connection Diagram
253
Release Contact X73-1 / -2
253
Alarm Input X73-3
253
Analog Output to the VSD X73-4
253
Voltage
253
Speed Feedback Signal
254
Speed Input X70
254
Sensor Disk
254
Speed Sensor
254
Selection of Fan Motor
254
Fuel Meter
255
Fuel Meter Input X71 / X72
255
Configuration of VSD
255
Configuration of Speed Acquisition
256
Standardization
256
Note
256
Settling Time
257
Configuration of Current Interface
258
Configuration of Fuel Meter
258
Pulse Value Gas
258
Pulse Value Oil
258
Fuel Meter Readings
259
Process Data
259
Advertisement
Advertisement
Related Products
Siemens LMV51.000C2
Siemens LMV51.040C1
Siemens LMV51.040C2
Siemens LMV51.000C1
Siemens LMV51.000B1
Siemens LMV51.040B1
Siemens LMV51.000A1
Siemens LMV51.000A2
Siemens LMV51.100C2
Siemens LMV51.300B1
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL