free stats
NEC HT1000 Installation Manual
Hide thumbs Also See for HT1000:

Advertisement

HT1000/1100 Installation Guide
Used with optional NEC Anamorphic Lens (HT169-Lens)
Contents
Product Description, Lens Specs, Screen/Aspect Ratio,
Notes and Formulas
Diagrams & Distance Charts
Cabinet Dimensions; Top, Front and Right
Bottom, Back and Left
Ceiling Mount Dimensions
Input Panel and Control Codes
Product Description
Type:
1 chip DMD
Resolution:
1024 x 768 (Anamorphic mode)
Aspect Ratio:
16:9
Contrast Ratio:
HT1000: 3000:1 (2000:1 Iris open)
HT1100: 3500:1 (2000:1 Iris open)
Std Lens Specifications
Throw Ratio:
1.5-1.9:1 (for 100" diagonal)
°
Offset Angle:
15.8
-18.8
Screen Sizes:
40"-200" diagonal (16:9)
30"-200" diagonal (4:3)
NEC Anamorphic Lens (HT169-Lens)
The optional NEC Anamorphic Lens attaches to the existing standard lens without changing throw distance or image size. The lens
performs a vertical squeeze allowing the full 4:3 panel resolution (1024x768) to be used and have the image fit a 16:9 screen
appropriately. The lens causes a minor shift vertically to the image position, the values in the formulas below takes this into account.
Screen/Aspect Ratio
A 16:9 screen is recommended for best use of the anamorophic lens and the projectors aspect ratio contols.
The "Anamorphic" setting should be selected in the "Setup/Screen" menu when the projector is used with the optional NEC
Anamorphic Lens. This setting configures the aspect ratio controls so they work appropriately when an anamorphic lens is
used. Aspect ratio control is available for both 16:9 and 4:3 sources using NEC developed scaling technology.
*Firmware is available for the HT1000 allowing 'Anamorphic' mode to be selected in the 'Screen' menu.
Notes
For screen sizes not indicated in the projection charts, use the formulas below.
The ceiling must be strong enough to support the projector and the installation must be in accordance with any local
building codes.
Distances are in inches, for millimeters multiply by 25.4.
Distances may vary ±5%.
Formulas
The Projection Formulas use the image width for calculation. Image width is the same for all aspect ratios, only vertical image size
varies. For proper projector placement, determine the image width for a desired screen size. Use the Screen Formulas below to
calculate all screen dimensions. Plug in the image width for "W" in the Projection Formulas.
Refer to the diagrams and charts for popular screen sizes on page 2.
Note: Distances are measured at the standard lens. The Anamorphic lens is attached after installation.
Projection Formulas: (using a 16:9 screen)
B = 0.54405W – 0.021
C(wide) = 1.5607W – 1.751
C(tele) = 1.8789W – 1.694
D = 0.2628W – 0.021
α(wide) = tan
-1
(B/C(wide))
α(tele) = tan
-1
(B/C(tele))
Note: Vertical Position is not available in Anamorphic mode.
www.necvisualsystems.com
TM
projector
°
(for 100" diagonal)
NEC Solutions (America), Inc.
Pg 1
Pg 2
Pg 3
Pg 4
Pg 5
Pg 6
Color Wheel: 6 Segments (improved in HT1100)
Dimensions: 10.24"(W) x 4.74"(H) x 12.56"(D)
Weight:
7.1 lbs
Brightness:
HT1000: 1000 ANSI Lumens
HT1100: 1100 ANSI Lumens
Manual Focus/Manual Zoom/Manual Iris
Focal Length:
22.4mm – 27.0mm
F/#:
HT1000: 2.5 – 3.7
HT1100: 2.5 – 4.5 (due to new Iris)
Definitions:
W = Image Width
H = Image Height (Size)
B = Vertical distance between lens center and screen center
C = Throw distance
D = Vertical distance between lens center and screen bottom
(screen top for ceiling mounted application)
16:9 Screen Formulas:
W = H x 16/9
H = W x 9/16
Screen Diagonal = W x 18.358/16
HT1000/1100 + Anamorphic Lens
Visual Systems
v1.0
Page 1 of 6

Advertisement

Table of Contents
loading

Summary of Contents for NEC HT1000

  • Page 1 NEC Anamorphic Lens (HT169-Lens) The optional NEC Anamorphic Lens attaches to the existing standard lens without changing throw distance or image size. The lens performs a vertical squeeze allowing the full 4:3 panel resolution (1024x768) to be used and have the image fit a 16:9 screen appropriately.
  • Page 2: Ceiling Mounted Installation

    Note: For screen sizes not indicated on the chart, 75.6 215.2 - 259.5 36.5 19.4 - 16.2 use the formulas on page 1. 76.1 216.7 - 261.4 36.8 19.4 - 16.2 www.necvisualsystems.com HT1000/1100 + Anamorphic Lens Page 2 of 6...
  • Page 3: Cabinet Dimensions

    The following drawings show the cabinet dimensions. Dimensions are in inches. For millimeters multiply by 25.4. 2.756 2.244 VENTILATION 3.169 10.236 4.213 4.724 VENTILATION NEC Anamorphic Lens attached to Std. Lens 3.96 2.303 1.378 7.362 www.necvisualsystems.com HT1000/1100 + Anamorphic Lens Page 3 of 6...
  • Page 4 Cabinet Dimensions (continued) The following drawings show the cabinet dimensions. Dimensions are in inches. For millimeters multiply by 25.4. VENTILATION FOR CEILING MOUNT 2.559 4.213 3-M4x10 SECURITY SLOT 2.303 www.necvisualsystems.com HT1000/1100 + Anamorphic Lens Page 4 of 6...
  • Page 5 Dimensions are in inches. For millimeters multiply by 25.4. The LT60CM comes with a threaded pipe base and a flush base for minimal mount height. 7.52 Threaded Pipe Base 3.54 1.5" NPT Cable Management 8.12 Flush Base www.necvisualsystems.com HT1000/1100 + Anamorphic Lens Page 5 of 6...
  • Page 6: Input Panel

    FULL ZOOM STADIUM ASPECT RATIO (4:3 Screen) NORMAL ZOOM CINEMA V-ZOOM Note: Contact your NEC rep for codes not listed. Cable Connection Communication Protocol: PC Control Connector (DIN-8P) Baud Rate: 38400 bps Data Length: 8 bits To RxD of PC...

This manual is also suitable for:

Ht1100

Table of Contents