Page 8
Read any additional safety information that comes with the server or optional device before you install the device. This device is intended for use with UL Listed BladeCenters. BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
Page 9
Statement 1: DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet. v Connect to properly wired outlets any equipment that will be attached to this product.
Page 10
Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil A Laser de Classe 1 viii BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
Page 11
Statement 8: CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components.
BladeCenter components, see the BladeCenter documentation that comes with these devices. To support each BladeCenter Virtual Fabric 10Gb Switch Module that you install in the BladeCenter unit, you must also install a compatible high-speed Ethernet expansion card (also known as an Ethernet I/O card) in each blade server that you want to communicate with the switch module.
Page 14
BladeCenter Virtual Fabric 10Gb Switch Module Model number _____________________________________________ Serial number _____________________________________________ Part number _____________________________________________ Media access control (MAC) _____________________________________________ address for switch module MAC addresses for other _____________________________________________ components _____________________________________________ _____________________________________________ BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
Installation and User's Guide v Application Guide for the BladeCenter Virtual Fabric 10Gb Switch Module v BBI Quick Guide for the BladeCenter Virtual Fabric 10Gb Switch Module v Menu-Based CLI Command Reference for the BladeCenter Virtual Fabric 10Gb Switch Module...
Danger: These statements indicate situations that can be potentially lethal or extremely hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation. BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
For more information about the components of the information panel, see Chapter 6, “Information panels, LEDs, and external ports,” on page 25. Chapter 1. The BladeCenter Virtual Fabric 10Gb Switch Module...
A removed hot-swap module is replaced with an identical module or filler module within 1 minute of removal. v A removed hot-swap blade server is replaced with another blade server or filler blade within 1 minute of removal. BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
v The ventilation areas on the sides of the blade server are not blocked. v You have followed the reliability guidelines in the documentation that comes with the BladeCenter unit. Cable requirements for the switch module are described in the Configuration and Options Guide at http://www-03.ibm.com/systems/xbc/cog/search.html.
9. Push the release levers on the front of the switch module to the closed position. After you insert and lock the switch module, it is turned on, and a power-on self-test (POST) occurs to verify that the switch module is operating correctly. BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
Page 23
Notes: a. The switch module takes approximately 60 seconds to complete the POST. When the switch module is turned on, an LED test occurs. All LEDs are lit and remain lit during POST; then, all the LEDs except the OK LED turn off.
Chapter 4, “Cabling the switch module and the SFP+ module,” on page 19, the documentation that comes with the cables, and the optional network devices to which the cables have been connected. For the locations of the connectors on BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
Page 25
the BladeCenter unit, see the documentation that comes with the BladeCenter unit. Then, continue with Chapter 3, “Installing and removing a 10 Gb SFP+ module,” on page 15. Chapter 2. Installing and replacing a switch module...
Page 28
Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil A Laser de Classe 1 BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
Installing an SFP+ module The SFP+ module provides two fiber-optic cable connectors for connecting to external ports. To install an SFP+ module, complete the following steps: 1. Read the safety information that begins on page v and “Installation guidelines” on page 8. 2.
5. Grasp the wire tab on the SFP+ module and pull it out of the port. 6. Replace the protective cap on the SFP+ module and the SFP+ module port. 7. Place the SFP+ module into a static-protective package. BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
To disconnect the SFP+ module cable, complete the following steps: 1. Squeeze the release tabs and gently pull the fiber optic cable from the SFP+ module. 2. Replace the protective caps on the ends of the fiber optic cable. BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
Connecting the RJ-45 cable The RJ-45 cable can be connected to port 11. To connect the RJ-45 connector to the switch module, push the RJ-45 cable connector into the port connector until it clicks into place, as shown in the following illustration.
Note: You can also use the management module to make sure that the switch module is operating correctly. For more information, see the documentation for the BladeCenter unit. BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
Switch-module status LEDs The following table provides descriptions of the switch-module status LEDs on the front panel of the switch module. Table 1. Switch-module status LEDs Status LED Description This green LED is at the top left of the switch module on the front OK ( ) LED panel.
Structural parts: Purchase and replacement of structural parts (components such as the top cover) is your responsibility. If Lenovo acquires or installs a structural part at your request, you will be charged for the installation.
Lenovo to assist you. Use this information to obtain additional information about Lenovo and Lenovo products, and determine what to do if you experience a problem with your Lenovo system or optional device. Note: This section includes references to IBM web sites and information about obtaining service.
The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device drivers or other software. Lenovo maintains pages on the World Wide Web where you can get the latest technical information and download device drivers and updates.
In the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378). Hardware service and support IBM is Lenovo's preferred service provider for the System x, Flex System and NeXtScale System products. You can receive hardware service through your Lenovo reseller or from IBM. To locate a reseller authorized by Lenovo to provide warranty service, go to http://www.ibm.com/partnerworld/ and click Business Partner Locator.
Taiwan product service Use this information to contact IBM Taiwan product service. IBM Taiwan product service contact information: IBM Taiwan Corporation 3F, No 7, Song Ren Rd. Taipei, Taiwan Telephone: 0800-016-888 BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...
(TBW). A device that has exceeded this limit might fail to respond to system-generated commands or might be incapable of being written to. Lenovo is not responsible for replacement of a device that has exceeded its maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the device.
Lenovo makes no representations or warranties with respect to non-Lenovo products. Support (if any) for the non-Lenovo products is provided by the third party, not Lenovo. Some software might differ from its retail version (if available) and might not include user manuals or all program functionality.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Lenovo is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
Grenzwerte der EN 55022 Klasse A ein. Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der Lenovo empfohlene Kabel angeschlossen werden. Lenovo übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der Lenovo verändert bzw.
Korea Communications Commission (KCC) statement This is electromagnetic wave compatibility equipment for business (Type A). Sellers and users need to pay attention to it. This is for any areas other than home. BladeCenter Virtual Fabric 10Gb Switch Module: Installation Guide...