Managing the Switch
fan1
fan2
fan3
N/A - Per module power not available
Power Usage Summary:
--------------------
Power Supply redundancy mode (configured)
)
Power Supply redundancy mode (operational)
)
Total Power Capacity (based on configured mode)
Total Power of all Inputs (cumulative)
Total Power Output (actual draw)
Total Power Input (actual draw)
Total Power Allocated (budget)
Total Power Available for additional modules
switch#

Power Cycling a Module

You can reset a module by using the reload module slot_number command and specifying the module by its
slot number in the chassis.
Reloading a module disrupts traffic through the module.
Caution
Note
To see which slots are filled with modules, use the show inventory command.
Step 1
Use the configure terminal command to enter the global configuration mode.
Example:
switch# configure terminal
switch(config)#
Step 2
Use the reload module slot_number command to specify the slot number of the module to reset.
Example:
switch(config)# reload module 4
This command will reload module 4. Proceed[y/n]?
reloading module 4 ...
switch(config)#

Rebooting a Switch

You can reboot or reload the switch by using the reload command without any options.
OL-30837-01
N9K-C9508-FAN
N9K-C9508-FAN
N9K-C9508-FAN
Cisco Nexus 9508 Switch Site Preparation and Hardware Installation Guide
47 W
225.00 W
Powered-Up
48 W
225.00 W
Powered-Up
47 W
249.00 W
Powered-Up
Non-Redundant(combined
Non-Redundant(combined
3000.00 W
3000.00 W
517.00 W
566.00 W
1728.24 W
1271.76 W
[n] y