hit counter script

Lenovo System x3250 M4 Installation And Service Manual page 516

Table of Contents

Advertisement

Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
201-845-002 : Standalone Memory Test Aborted
Chipset Error: Problem clearing MSR machine check control registers.
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
502
Lenovo System x3250 M4 Installation and Service Guide