SPLIT-TYPE, AIR CONDITIONERS
SERVICE TECHNICAL GUIDE
Wireless type
Models
MS-A08ND -
MS-A10ND -
MS-A12ND -
MS-A15ND -
· MU-A08ND -
(WH)
C1
· MU-A10ND -
(WH)
C1
· MU-A12ND -
(WH)
C1
· MU-A15ND -
(WH)
C1
CONTENTS
MICROPROCESSOR CONTROL
1."I FEEL CONTROL" OPERATION ·································2
2. COOL OPERATION ·······················································5
3. DRY OPERATION ··························································5
4. FAN OPERATION ··························································5
5. FAN MOTOR CONTROL ···············································5
6. AUTO VANE OPERATION·············································5
7. TIMER OPERATION ······················································7
8. EMERGENCY / TEST OPERATION ······························7
No. OBT10
C1
C1
C1
C1
TM

Advertisement

loading

Summary of Contents for Mitsubishi Electric MS-A08ND

  • Page 1 SPLIT-TYPE, AIR CONDITIONERS No. OBT10 SERVICE TECHNICAL GUIDE Wireless type Models MS-A08ND - · MU-A08ND - (WH) MS-A10ND - · MU-A10ND - (WH) MS-A12ND - · MU-A12ND - (WH) MS-A15ND - · MU-A15ND - (WH) CONTENTS MICROPROCESSOR CONTROL 1.“I FEEL CONTROL” OPERATION ·································2 2.
  • Page 2: Microprocessor Control

    MICROPROCESSOR CONTROL MS-A08ND - MS-A10ND - MS-A12ND - MS-A15ND - MU-A08ND - MU-A10ND - MU-A12ND - MU-A15ND - Once the operation mode are set, the same operation mode WIRELESS REMOTE CONTROLLER can be repeated by simply turning the OPERATE/STOP(ON/OFF) button ON.
  • Page 3 (4) The initial set temperature is decided by the initial room temperature. Initial room temperature Initial set temperature Mode 24°C 26°C or more COOL mode of “I FEEL CONTROL” Initial room temperature 25°C to 26°C °C minus 2 Initial room temperature DRY mode of more than13°C, less than 25°C “I FEEL CONTROL”...
  • Page 4 Time control When the three conditions as follows have been satisfied for 1 hour and 45 minutes, compressor stops for 3 minutes. a. Compressor has been continuously operating. b. Indoor fan speed is Low or Med.. c. Room temperature is below 26°C. When compressor stops, the value of its duration measure is reset.
  • Page 5 2. COOL ( ) OPERATION (1) Press OPERATE/STOP(ON/OFF) button. OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone. (2) Select COOL mode with OPERATION SELECT button. (3) Set TEMPERATURE buttons. Press TOO WARM or TOO COOL button to select the desired temperature.
  • Page 6 (3) Positioning The vane is once pressed to the vane stopper below to confirm the standard position and then set to the desired angle. Confirming of standard position is performed in case of follows. (a) When OPERATE / STOP(ON/OFF) button is pressed. (POWER ON/OFF) (b) When the vane control is changed from AUTO to MANUAL.
  • Page 7 (9) POWERFUL COOL ( ) mode When POWERFUL COOL button is pressed in COOL mode, the fan speed and the set temperature are automatically adjusted. Operation becomes POWERFUL COOL mode. POWERFUL COOL mode is automatically released 15 minutes after operation starts, and the operation mode returns to the mode prior to POWERFUL COOL operation.