free stats
NEC NEAX2400 ICS Installation Notes
NEC NEAX2400 ICS Installation Notes

NEC NEAX2400 ICS Installation Notes

Isdn pri
Hide thumbs Also See for NEAX2400 ICS:

Advertisement

NEC America Inc.
CNG Product Development Division (PDD)
NEAX2400 ICS ISDN PRI
Installation Notes
DESCRIPTION
This Engineering Technical Information (ETI) bulletin describes installation procedures for NEAX2400
ICS ISDN Primary Rate Interface (PRI). For additional information sources, refer to the documents listed
in the
References
section of this ETI.
CONTENTS
1.
GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.
ISDN OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1
Layer 1 Physical Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.2
ISDN PRI Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.3
ISDN PRI Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.
HARDWARE/SOFTWARE REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.
CIRCUIT CARD (PA-24PRT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5.
DATA ASSIGNMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.1
ISDN PRI Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2
ASYD Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.3
ARTD Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.3.1
5.3.2
5.4
Examples of Office Data Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.4.1
5.4.2
5.4.3
5.5
ACBC Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.5.1
5.5.2
5.5.3
5.5.4
5.5.5
6.
TEST METHOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
7.
REFERENCES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Page 1
ETI-152A
ARTD Assignment for "B" Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ARTD Assignment for "D" Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Example 1: ADPC, ACSC and ACIC Commands. . . . . . . . . . . . . . . . . . . 15
External Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Floppy Disk Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Related Reference Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Entry Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
ENGINEERING TECHNICAL INFORMATION
E T I
Volume 5, Issue 3
September, 1997
PAGE
ETI-152A

Advertisement

Table of Contents
loading

Summary of Contents for NEC NEAX2400 ICS

  • Page 1: Table Of Contents

    NEC America Inc. CNG Product Development Division (PDD) ENGINEERING TECHNICAL INFORMATION E T I ETI-152A NEAX2400 ICS ISDN PRI Installation Notes Volume 5, Issue 3 September, 1997 DESCRIPTION This Engineering Technical Information (ETI) bulletin describes installation procedures for NEAX2400 ICS ISDN Primary Rate Interface (PRI). For additional information sources, refer to the documents listed...
  • Page 2: General Description

    This ETI describes the installation procedures and office data assignment for connecting ISDN lines to NEAX2400 ICS. The ISDN PRI (Primary Rate Interface 23B + D) allows a station user to gain access to a variety of services, associated with the ISDN, based on the office data assigned.
  • Page 3: Isdn Pri Services

    The PBX supports User to Network protocol; however, provision has been made for the PBX to be configured as a network for test purposes. In applications where two PBXs are connected via private lines, one PBX may be configured as a network (however, NEC does not guaranty this type of operation).
  • Page 4: Hardware/Software Requirements

    NEAX2400 ICS ISDN PRI Installation Notes HARDWARE/SOFTWARE REQUIREMENTS The following minimum requirements are necessary for this installation. 1. Required software: • ICS IMG must be version B5.1 or higher. • ICS MMG must be version B6.4 or higher. 2. Required firmware: •...
  • Page 5 NEAX2400 ICS ISDN PRI Installation Notes Table 1 contains ISDN switch names and descriptions. Table 1 ISDN PRI Switch Descriptions SWITCH SWITCH SWITCH SWITCH KIND OF SWITCH MEANING NAME LOCATION SETTING Front Circuit card make busy DOWN Circuit card make busy...
  • Page 6 NEAX2400 ICS ISDN PRI Installation Notes Table 1 ISDN PRI Switch Descriptions (Continued) SWITCH SWITCH SWITCH SWITCH KIND OF SWITCH MEANING NAME LOCATION SETTING Parts Dip Switch Impedance Setting: 100 Ω Mounted 1 2 3 4 Face Impedance Setting: 110 Ω...
  • Page 7 NEAX2400 ICS ISDN PRI Installation Notes Table 1 ISDN PRI Switch Descriptions (Continued) SWITCH SWITCH SWITCH SWITCH KIND OF SWITCH MEANING NAME LOCATION SETTING Parts Dip Switch 1 ~ 3 Equalizer Setting Mounted Distance SW2-1 SW2-2 SW2-3 1 2 3 4 5 6 7 8...
  • Page 8 NEAX2400 ICS ISDN PRI Installation Notes Table 1 ISDN PRI Switch Descriptions (Continued) SWITCH SWITCH SWITCH SWITCH KIND OF SWITCH MEANING NAME LOCATION SETTING Parts Dip Switch 1, 2 Alarm Sending when this Mounted circuit card is in N-OPE 1 2 3 4 5 6 7 8 Face state.
  • Page 9 NEAX2400 ICS ISDN PRI Installation Notes Table 1 ISDN PRI Switch Descriptions (Continued) SWITCH SWITCH SWITCH SWITCH KIND OF SWITCH MEANING NAME LOCATION SETTING Parts Dip Switch 1 ~ 3 PAD Pattern Selection Mounted SW5-1 SW5-2 SW5-3 1 2 3 4 5 6 7 8...
  • Page 10 Table 2 is an example of switch settings for ISDN with ESF and B8ZS. The configuration shown below is recommended for ISDN PRI, and is used for ESF and B8ZS settings and connection of the NEAX2400 ICS to network ISDN PRI. Table 2 PA-24PRT Switch Settings for ISDN PRI...
  • Page 11: Data Assignment

    NEAX2400 ICS ISDN PRI Installation Notes Table 3 shows lamp indications for the PA-24PRT card. Table 3 Lamp Indications LAMP NAME COLOR STATE OPE Note Green Remains lit while this circuit card is operating. N-OPE Remains lit while this circuit card is in make-busy state.
  • Page 12: Asyd Command

    NEAX2400 ICS ISDN PRI Installation Notes ADPC Assign the determined point code. Same point code is used for the B and D route of one interface. If more than one ISDN link is used and no NFAS is used, each interface will have a different point code.
  • Page 13: Artd Command

    NEAX2400 ICS ISDN PRI Installation Notes ARTD Command 5.3.1 ARTD Assignment for “B” Channel B-Channel must be assigned separately for each ISDN link. Route 11 ISDN “B” DATA NAME DATA DATA NAME DATA DATA NAME DATA OSGS ONSG ISGS RVSD...
  • Page 14: Artd Assignment For "D" Channel

    NEAX2400 ICS ISDN PRI Installation Notes Route 11 ISDN “B” (Continued) DATA NAME DATA DATA NAME DATA DATA NAME DATA SMDR4 The same value should be used in ARTD CDN 65 for B and D route. Note: CDN 65 = 5 for AT&T #4ESS and #5ESS CDN 65 = 7 for NT DMS100 and DMS250 5.3.2...
  • Page 15: Examples Of Office Data Assignment

    NEAX2400 ICS ISDN PRI Installation Notes Route 10 ISDN “D” (Continued) DATA NAME DATA DATA NAME DATA DATA NAME DATA SMDR2 LYER1 TDMQ TRSC (Note 2) SMDR4 Note 1: 7 is the only valid PAD value for the D Channel.
  • Page 16 NEAX2400 ICS ISDN PRI Installation Notes ADPC RT11 (B Route) PC=1 RT10 (D Route) PC=1 ACIC CSC=130 No LEN Space Bar 2 times ACSC 130 = LEN of the DCH D Channel (See Figure 131 = Same LEN as 130...
  • Page 17 NEAX2400 ICS ISDN PRI Installation Notes Channel 1D Group 15 Group 14 B Channels Group 13 Group 12 LEN for CSC = Even CSC = Odd Channel 2D Preferred mounting slots are 10, 11, 12, 21, 22 and 23. Note 1: Each ISDN interface requires assignment of 23 B channels and 2 D channels.
  • Page 18: Example 2: Adpc, Acsc And Acic Commands (Pa-24Prtb-A)

    NEAX2400 ICS ISDN PRI Installation Notes 5.4.2 Example 2: ADPC, ACSC and ACIC Commands (PA-24PRTB-A) Figure 2 shows an example of office data assignment when PA-24PRTB-A is mounted in a 16 port slot. Slot No. PIM0 Group No. (G) Figure 2 Example of 24PRT (PRI) Mounting The table below shows relations of parameters assigned in ADPC, ACSC and ACIC Commands.
  • Page 19 NEAX2400 ICS ISDN PRI Installation Notes Figure 3 shows an example of office data assignment for ATRK Command (PA-24PRTB-A) in a 16 port slot. 24PRTB-A(PRI) MOUNTING SLOT TK8 (B) TK1 (D) TK7 (B) TK23 (B) TK6 (B) TK22 (B) Odd-...
  • Page 20: External Interface

    NEAX2400 ICS ISDN PRI Installation Notes 5.4.3 External Interface Accommodation of the LT connector leads of this circuit card are shown in Figure 4 for PA-24PRT. Figure 4 24PRT LT Connector Leads Accommodation ETI-152A Page 20...
  • Page 21 NEAX2400 ICS ISDN PRI Installation Notes Accommodation of the PL0 LT Cable Connection leads of this circuit card are shown in Figure 5. Figure 5 PLO LT Cable Connection Page 21 ETI-152A...
  • Page 22: Acbc Command

    NEAX2400 ICS ISDN PRI Installation Notes Figure 6 shows the connecting routes for accommodation of the LT connector leads to the PRT and PL0 circuit cards. Figure 6 Connecting Route Diagram ACBC Command ACBC: Assignment of Call by Call Service 5.5.1...
  • Page 23: Entry Procedure

    NEAX2400 ICS ISDN PRI Installation Notes 5.5.5 Entry Procedure • For AT&T and Feature Access Assignment of Call by Call Service Data TDPTN:0 OPR:0 RA:0 MD:0 INT:0 NET:0 SERV:0 CODE:0 SCC:288 SCC 288 = Transmit Network Selection code for AT&T...
  • Page 24 NEAX2400 ICS ISDN PRI Installation Notes • For AT&T and Service Access (SDN) Assignment of Call by Call Service Data TDPTN:0 OPR:1 RA:0 MD:0 INT:0 NET:0 SERV:1 CODE:1 BAND:1 SCC:201 WRT? ACBC COMMAND DATA NAME ASSIGNMENT/REMARKS TDPTN Time of Day Change Pattern (0-7)
  • Page 25 NEAX2400 ICS ISDN PRI Installation Notes • For AT&T and Service Access (MEGACOM, etc.) Assignment of Call by Call Service Data TDPTN:0 OPR:1 RA:0 MD:0 INT:0 NET:0 SERV:1 CODE:1 BAND:1 SCC:201 WRT? ACBC COMMAND DATA NAME ASSIGNMENT/REMARKS TDPTN Time of Day Change Pattern (0-7)
  • Page 26 NEAX2400 ICS ISDN PRI Installation Notes • For NT (Public, etc.) Assignment of Call by Call Service Data TDPTN:0 OPR:1 RA:0 MD:0 INT:0 NET:1 SERV:0 CODE:0 WRT? ACBC COMMAND DATA NAME ASSIGNMENT/REMARKS TDPTN Time of Day Change Pattern (0-7) Outgoing Route Selection Pattern Number (0-4095)
  • Page 27 NEAX2400 ICS ISDN PRI Installation Notes • For NT (OUTWATS) Assignment of Call by Call Service Data TDPTN:0 OPR:1 RA:0 MD:0 INT:0 NET:1 SERV:0 CODE:3 BAND:0 WRT? ACBC COMMAND DATA NAME ASSIGNMENT/REMARKS TDPTN Time of Day Change Pattern (0-7) Outgoing Route Selection Pattern Number (0-4095)
  • Page 28: Test Method

    NEAX2400 ICS ISDN PRI Installation Notes TEST METHOD The following test method will allow you to verify the proper operation of the ISDN PRI in the PBX without a physical connection to the network. In order to accomplish a ISDN PRI internal test, two 24PRTs are necessary - one PRT configured as the user side (normal operation) and the second PRT configured as the network side.
  • Page 29: References

    NEAX2400 ICS ISDN PRI Installation Notes REFERENCES Command Manual (Stock # 200705) ISDN Feature and Specifications Manual (Stock # 200710) Page 29 ETI-152A...

Table of Contents