free stats
Download Print this page
Sealey GSS150819SDG Instructions Manual
Sealey GSS150819SDG Instructions Manual

Sealey GSS150819SDG Instructions Manual

Galvanized steel shed 1.5 x 0.8 x 1.9m with side door

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE
PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL
INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when building this shed.
Keep the work area clean, uncluttered and ensure there is adequate lighting.
Keep children and unauthorised persons away from the working area.
DO NOT use the shed for any purpose other than that for which it is designed.
Use appropriate safety clothing including eye protection.
Note: The assembly of this product will require assistance.
DO NOT attempt to assemble in windy weather.
2. INTRODUCTION
Galvanized, steel panels easily assembled to form a rigid and secure shed. Has skillion (sloping) roof and single door. Door are secured by cross
bolt and eyelet which will accept a padlock (not included) for additional security. Supplied with bolt-down fixing kit.
3. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . . GSS150819SDG
Overall Size (W x D x H*): . . . . . . . . 1500 x 800 x 1900mm
Roof Type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Skillion
* Minimum wall height
© Jack Sealey Limited
INSTRUCTIONS FOR:
SHED 1.5 x 0.8 x 1.9m WITH SIDE DOOR.
GSS150819SDG
MODEL NO:
Original Language Version
GALVANIZED STEEL
GSS150819SDG Issue: 1 - 27/08/14

Advertisement

loading

Summary of Contents for Sealey GSS150819SDG

  • Page 1 3. SPECIFICATION Model No: ......GSS150819SDG Overall Size (W x D x H*): ..1500 x 800 x 1900mm Roof Type: .
  • Page 2: Tools Required

    50mm edge around your shed. We recommend that you slope the 50mm edges downward by 10mm so that rain water will drain away from your shed. 5. TOOLS REQUIRED Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 3 Check contents: Lay out all components with the part numbers facing upwards and check off against the parts lists on the next four pages. In the unlikely event of a missing component please contact you local Sealey dealer. sheet 1980 x 770...
  • Page 4 Please note some component descriptions may differ in manual text to listings, always use pictures from listings to double check 6.1. component identity. ie M8 fixings may be supplied in lieu of 5/16”. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 5: Parts Diagram

    7. PARTS DIAGRAM Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 6 You will find it easier to assemble the shed using trestles with timber studding of equal or greater panel length. Trestles can be supplied separately by your Jack Sealey dealership. Attach the studding to trestles with equal overhang using nylon cable ties or similar “safe”...
  • Page 7 Fit item 38A the mid height wall channel to the panel and position it by the pre-punched holes and 10mm long self tapping screws. Note this channel is fitted with the flat face uppermost. 8.1.5. With self tapping screws fix items 20B and 20C to top and bottom edges. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 8 With self tapping screws fix item 21B to bottom edge, but do not screw fix item 21A to top edge at this stage,see places marked with asterisk *. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 9 The outside face is the diagram. Fix both with 10mm long self tapping screws except for positions marked with asterisk *, which are not fixed at this stage. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 10 Fit item 38B the mid height wall channel to the panel and position it by the pre-punched holes and 10mm long self tapping screws. Note this channel is fitted with the flat face uppermost, ie. nearest the “top”. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 11 Note that the smaller flange on the channels should always be adjacent to the outside face of the panel. The outside face is the top face in both diagrams. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 12 8.4.3. Fit item 50 (angles) to each edge, refer to diagram this page for flange orientation. Fix with 10mm long self tapping screws. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 13 Attach the side wall 2E to the rear wall 1A & 1L, then the front wall 9A & 9S. Fix all walls with the 10mm long self tapping screws. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 14 Install the front frame per following diagrams. The door mullion sections are fixed with 16mm long self tapping screws. Do not fix self tapping screws marked * in enlarged ballooned views at this stage. FIX DOOR MULLION SECTIONS WITH SIX 16mm LONG SELF TAPPING SCREWS Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 15 Fix the channel item 21H with 16mm long self tapping screws. 8.6.3. Slide and tap on top channel item 21J, but do not screw fix at this stage. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 16 Fit the shoot bolt item 70 and the bolt keeper item 71 and fix with 10mm long self tapping screws or 4mm diameter rivets, (fitting method A or B) Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 17 Please note anchor bolts and M8 machine screws are supplied, see “FITTINGS PACK”. 8.8.3. Insert anchor bolts, re-fit steel angles and anchor shed to plinth slab. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...
  • Page 18 When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable) into approved containers and dispose of the product and the fluids according to local regulations. Original Language Version GSS150819SDG Issue: 1 - 27/08/14 © Jack Sealey Limited...