free stats
Download Print this page
Sealey GSS150815 Instructions Manual
Sealey GSS150815 Instructions Manual

Sealey GSS150815 Instructions Manual

Galvanized steel shed 1.5 x 0.8 x 1.5m
Hide thumbs Also See for GSS150815:

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
refer to
Wear eye
instruction
protection
manual
1. SAFETY
WARNING! ensure Health & safety, local authority, and general workshop practice regulations are adhered to when building this shed.
Keep the work area clean, uncluttered and ensure there is adequate lighting.
9
Keep children and unauthorised persons away from the working area.
9
DO NOT use the shed for any purpose other than that for which it is designed.
8
use appropriate safety clothing including eye protection.
9
DO NOT attempt to assemble in windy weather.
8
Note: the assembly of this product will require assistance.
2. INTRODucTION
Galvanized steel panels easily assembled to form rigid and secure structure. flat roof and double doors, secured by cross bolt and eyelet which
will accept a padlock (not included) for additional security. Supplied with bolt down fixing kits.
3. SpEcIFIcATION
model no: ......................................................... Gss150815G
colour: ..........................................................................green
roof type:.......................................................................... flat
doors: .................................................................................. 2
overall size (W x D x H*): ................... 1500 x 800 x 1500mm
note: *minimum wall height
4. cONcRETE pLINTH
Please ensure that your site is level. it is recommended that your slab is 100mm thick and you use builders plastic and f52 reinforcing mesh.
We recommend that you make your slab 100mm bigger than the base dimensions of your shed. this will allow for a 50mm edge around your
shed. We recommend that you slope the 50mm edges downward by 10 mm so that rain water will drain away from your shed.
© Jack sealey limited
instructions for
GALVANIZED STEEL SHED
1.5 x 0.8 x 1.5M
model no:
Wear safety
Wear
footwear
gloves
Original Language Version
GSS150815 & GSS150815G
Gss150815/G| issue 2 (i) 21/04/17

Advertisement

loading

Summary of Contents for Sealey GSS150815

  • Page 1 GSS150815 & GSS150815G model no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Tools Required: Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 3 Door Sheet Sheet 1443x710 door Door Sheet Sheet 1443x710 door Channel channel 1477 roof roof channel 1477 Channel Channel channel 1477 rear wall channel 1477 Channel rear wall Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 4 718 Channel side wall jamb 1498 Jamb front jamb 1498 Jamb front jamb 1431 Jamb front Jamb 1498 Jamb Jamb Jamb 1498 lip 856 roof Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 5 Qty checking date: Qty checking personal badge number: Signature: In the unlikely event that you find you are missing a part, please contact Romak at 1800 702 660 . Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 6 Shed Overview Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 7 A ) or sliding it in. ( diagram B ) Be noted that the small lip of the channel is always facing out. This is to ensure that rainwater cannot build up inside your shed. Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 8 Now fit B5 mid wall channel to the sheeting and position it by the self-tapping screws. Please note that the groove should face downwards. Position the top and bottom channels by the self-tapping screws as well. Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 9 Be noted that the small lip of the channel is always facing out. This is to ensure that rainwater cannot build up inside your shed. Repeat the same steps for the other side wall. Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 10 Place 11B and 3A the sheeting on your worktable and join together with the self-tapping screws per the diagram. Now tap or slide in 39A and 39B the channels to the sheeting and fix them by the self-tapping screws. Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 11 Now fit 50A and 50A side lips to the sheeting and fix them by the self-tapping screws. Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 12 Step 5: Fit rear and side panels together and install the front frame. Attach the two side walls to the back wall, Fix all the components by the self-tapping screws. Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 13 Slide D3 the jamb into the top channel and fix with self-tapping screws. Note not to fix those depicted crossed untill D3 the jamb is in position. Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 14 Step 6: Install the front doors and the top panel. Fix 74 barrel bolt and 75 the plate onto 5M the door by rivets. Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 15 Fix 72 the brackets onto both corners. Fix 70 the pad bolt and 71 the keeper to the pre-drill holes by the 16mm self-tapping screws as well. (or the rivets provided ) Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 16 Now fit the bolt down kit per the diagram. Original Language Version Gss150815/G | issue 2 (i) 21/04/17 © Jack sealey limited...
  • Page 17 To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500. Environmental protection Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

This manual is also suitable for:

Gss150815g