free stats
Download Print this page
Sealey VS904.V2 Instructions
Sealey VS904.V2 Instructions

Sealey VS904.V2 Instructions

Infrared laser digital thermometer

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1. General Safety
WARNING! Ensure that Health & Safety, local authority and general workshop practice regulations
are adhered to when using this equipment.
WARNING! DO NOT aim the laser beams at your or another person's or animal's eye and beware of
reflections from mirrors or other shiny surfaces.
Familiarise yourself with the applications, limitations, and potential hazards of the thermometer.
Keep the thermometer clean and in good condition.
Protect the thermometer from the following:
Electro-magnetic fields from engine components, arc welders and induction heaters closer than 125mm.
Static electricity.
Thermal shock caused by large and/or rapid ambient temperature change.
High temperatures.
DO NOT get the thermometer wet or use in damp or wet locations or areas where there is condensation.
DO NOT take readings through transparent materials such as glass or clear plastic. The surface
temperature of these materials will be measured.
DO NOT use the thermometer in areas where there is steam, dust or smoke. These conditons will
result in erroneous readings.
DO NOT use the thermometer for any purpose other than that for which it is designed.
DO NOT allow untrained persons (particularly children) to operate the thermometer.
DO NOT operate the thermometer when you are tired or under the influence of alcohol, drugs or
intoxicating medication.
1.2. Laser Safety
The VS904.V2 utilises a Class II laser that emits low levels of visible radiation (i.e. wavelengths between 400 and 700 nanometres)
which are safe for the skin but not inherently safe for the eyes. The Class II emission limit is set at the maximum level for which eye
protection is normally afforded by natural aversion responses to bright light. Accidental eye exposure is therefore normally safe, although
the natural aversion response can be overridden by deliberately staring into the beam, and can also be influenced by the use of alcohol
or drugs.
WARNING! DO NOT look or stare into the laser beam as permanent eye damage could result.
Be aware that reflections of the laser beam from mirrors or other shiny surfaces can be as hazardous as direct eye exposure.
2. INTRODUCTION/SPECIFICATION
2.1.
Introduction
High resolution laser thermometer that detects energy emission in the infrared spectrum and converts reading into a display of temperature.
Features laser pointer, data hold function and auto power off. Temperature is displayed on a large 23mm LCD panel with back-lit display for
use in low light areas. Temperature can be shown in either °C or °F. The Digital Thermometer is powered by a 9V cell (supplied).
2.2.
Specification
Model No:....................................................................................... VS904.V2
Focal Ratio:............................................................................................... 12:1
Temperature Range:.......................................-50 to +550°C (-58 to +1022°F)
Accuracy:(0°C to 550°C)..................................+/- 1.5°C whichever is greater
(-50° to 0°C).................................................................. ....+/- 3°C
Resolution:................................................................................ 0.1°C or 0.1°F
Repeatability:............................................................................ 1% of reading
Response time:....................................................... 500mSec, 95% response
Spectral response: ............................................................................. 8-14μm
Emissivity:..................................................................................... 0.95 Preset
Operating Temperature: ........................................... 0 to +40°C (32 to 104°F)
Operating Humidity:............ 10 to 95%RH non-condensing up to 30°C (86°F)
Storage Temperature:.......................................... -20 to +60°C (-4 to +140°F)
Power:............................................................................ 9V battery (supplied)
Typical battery life:.................... Non laser mode: 22 hrs; Laser mode: 12 hrs
Weight: ................................................................................................. 147.5g
Dimensions: .......................................................... 153mm x 101mm x 43mm
© Jack Sealey Limited 2012
INSTRUCTIONS FOR:
DIGITAL THERMOMETER (12:1)
Model No: VS904.V2
Original Language Version
INFRARED LASER
C
B
A
G
LCD Display-:
A: Data hold icon
B: Scanning icon
C: Laser "ON" icon
D: Backlight "ON" icon
E: Battery status icon
F: Temperature units (C° or F°)
G: Temperature reading
VS904.V2
D
E
F
Issue: 2(SP) - 22/07/13

Advertisement

loading

Summary of Contents for Sealey VS904.V2

  • Page 1 1.2. Laser Safety The VS904.V2 utilises a Class II laser that emits low levels of visible radiation (i.e. wavelengths between 400 and 700 nanometres) which are safe for the skin but not inherently safe for the eyes. The Class II emission limit is set at the maximum level for which eye protection is normally afforded by natural aversion responses to bright light.
  • Page 2 Dispose of batteries according to local authority guidelines. Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme.