free stats
Download Print this page
Sealey AK457D Instructions
Sealey AK457D Instructions

Sealey AK457D Instructions

Oil drainer unit

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. USE
THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
! Replace damaged parts. Use genuine parts only. Non authorised parts may be dangerous and will invalidate the warranty.
! Keep the drainer clean and in good condition for best and safest performance.
! Wear appropriate protective clothing.
! Use drainer in an appropriate working area for its function. Keep area clean and tidy and free from unrelated materials and ensure
there is adequate lighting.
! Ensure the floor is not slippery and wear non slip shoes.
! Keep children and unauthorised persons away from the working area.
! Dispose of waste liquids in accordance with local authority regulations.
F WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment.
% DO NOT position drainer in such a way that it will cause potential hazards when moving, holding
for draining or storing.
I
IMPORTANT: AK450DX must be used in conjunction with a wall mounted air pump, model no: AK450DP
s
in order to discharge waste oil (not supplied with this unit).
2. DESCRIPTION & APPLICATION
2.1.
Description.
Drainers are steel fabricated and have a 75 litre reservoir with telescopic steel funnel fitted with filter
grid and drum full device.
Model AK457D is fitted with a gravity drain tap at the rear of the unit.
Model AK450DX has a dry-fit male coupling for connection to wall mounted air pump AK450DP.
2.2.
Application.
Drainer units are designed to collect waste oil of fluids via the vertically adjustable collection bowl.
Drainers are not suitable for vehicles above 3.5 tons for which you should use AK464DX or AK465D.
3. SPECIFICATIONS & ASSEMBLY
AK457D Specifications.
Maximum capacity . . . . . .75 litres
Min Height . . . . . . . . . . . .1180mm
Max Height . . . . . . . . . . .1750mm
Length . . . . . . . . . . . . . . . .590mm
Width . . . . . . . . . . . . . . . . .600mm
Discharge . . . . . . . . . . . . . .Gravity
Net weight . . . . . . . . . . . . . . .29kg
AK450DX Specifications.
Maximum capacity . . . . . .75 litres
Min Height . . . . . . . . . . . .1180mm
Max Height . . . . . . . . . . .1750mm
Length . . . . . . . . . . . . . . . .590mm
Width . . . . . . . . . . . . . . . . .600mm
Discharge . . . . . . . . . . . .air pump
Net weight . . . . . . . . . . . . . . .29kg
4. OPERATING INSTRUCTIONS
4.1.
Collection of waste oil
4.1.1. If unit has been used to drain a previous vehicle, check the oil level indicator float to ensure there is sufficient remaining capacity left
before you use the unit. If model AK457D is empty, ensure the evacuation tap is closed before you use the unit.
4.1.2. Place the unit under the raised vehicle and adjust the collection bowl to the desired height and tighten the scalloped hand wheel
of the adjustable height adaptor.
4.2.
Evacuation of waste oil from unit. WARNING! ensure all waste is disposed of in accordance with local regulations.
4.2.1. AK457D position the gravity drain tap over a suitable outlet and open the tap.
4.2.2. AK450DX take the discharge hose of wall mounted pump unit AK450DP and connect the female coupling to the male coupling
of the pan unit and evacuate waste accordingly.
Drainer parts: (see parts diagram fig 1).
Reservoir with handle (item 5). 2 castor wheels (item 8 and 9). 2 rear wheels (item 14).
Adjustable collection bowl with drainage tube (items 2 & 3).
AK457D Gravity drain tap (item 15).
AK450DX Quick release connector (item 15).
Assembly. (see parts diagram fig 1).
1.
Unscrew the complete axle assembly from the transportation position. Use the nuts, bolts, and
washers that are provided to fit the axle assembly and position the castor wheels as illustrated
in the parts diagram.
2.
Screw the drainage tube (item 3) into the collection bowl (item 2).
3.
Introduce the drainage tube through the height adjustment adaptor into the reservoir and
tighten the scalloped hand wheel (item 4).
4.
Place the filter into the collection bowl (item 1).
INSTRUCTIONS FOR:
OIL DRAINER UNIT
AK457D
Models No:
AK450DX
&
AK457D & AK450DX - 2 - 020304

Advertisement

loading

Summary of Contents for Sealey AK457D

  • Page 1 4.1.1. If unit has been used to drain a previous vehicle, check the oil level indicator float to ensure there is sufficient remaining capacity left before you use the unit. If model AK457D is empty, ensure the evacuation tap is closed before you use the unit.
  • Page 2 INFORMATION: Call us for a copy of our latest catalogue on 01284 757525 and leave your full name and address including your postcode. Sole UK Distributor, Sealey Group, Bury St. Edmunds, Suffolk. www.sealey.co.uk 01284 757500 01284 703534 sales@sealey.co.uk e-mail 9A> AK457D & AK450DX - 2 - 020304...

This manual is also suitable for:

Ak450dx