thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. safety
Warning! ensure Health & Safety, local authority, and general
workshop practice regulations are adhered to when using this equipment.
Familiarise yourself with the application, limitations and hazards of the oil
9
drainer.
Maintain the drainer in good condition (use an authorised service agent).
9
Replace or repair damaged parts. Use genuine parts only. Unauthorised
9
parts may be dangerous and will invalidate the warranty.
Keep the work area clean, uncluttered and ensure there is adequate
9
lighting.
Keep the drainer clean for best and safest performance.
9
Maintain correct balance and footing. ensure the floor is not slippery
9
and wear non-slip shoes.
Keep children and unauthorised persons away from the work area.
9
Do not use the drainer for any purpose other than that for which it
8
is designed.
Do not operate the drainer if any parts are damaged or missing as
8
this may cause failure and/or personal injury.
Do not stand on the drainer.
8
Do not allow untrained persons to operate the drainer.
8
Do not operate the drainer when you are tired or under the influence
8
of alcohol, drugs or intoxicating medication.
When not in use, store in a safe, dry, childproof area.
9
dispose of waste oil in accordance with local authority regulations.
9
2. introDuction
Polyethylene reservoir, 36/80ltr capacity, mounted on four castors for mobility.
drain pan, with filter, on height adjustable down tube. Hand grips for emptying
(AK36d.V2): rotary pump or gravity drain tap for emptying (AK80d.V2)
3. specification
Model no:............................................................. aK36D.V2 .............................................................................. aK80D.V2
Air discharge: ................................................................... no ...........................................................................................no
Capacity: ......................................................................... 36ltr ........................................................................................ 80ltr
Collection Bowl Capacity (ltr): ......................................... 15ltr ........................................................................................ 15ltr
Gravity discharge: ............................................................ no ..........................................................................................Yes
Gravity Feed: ................................................................... Yes ..........................................................................................Yes
Manual discharge: ........................................................... Yes ..........................................................................................Yes
Maximum Height to Pan: .......................................... 1600mm ..................................................................................1800mm
Minimum Height to Pan: ............................................. 760mm ....................................................................................940mm
Model no: ...................................................................AK36d .................................................................................... AK80d
Pump discharge: .............................................................. no ...........................................................................................no
Suction Probe: .................................................................. no ...........................................................................................no
Temperature Range: .................................................... <80°C ..................................................................................... <80°C
4. asseMbly
4.1.
Insert the lower tube through lower tube clamp and secure by tightening the clamp.
4.2.
Place the tool tray over the lower tube.
4.3.
Insert the upper tube into the lower tube.
4.4.
Slide the upper tube retaining clip down the upper tube (press the two ends together to release the grip) until the clip rests on the lower
tube at the required level.
4.5.
Place the drain pan on top of the upper tube.
© Jack Sealey limited
36ltr/ 80ltr Mobile oil Drainer Manual
Discharge
Model no:
Wear protective
Wear protective
gloves
clothing
Original Language Version
aK36D.V2 & aK80D.V2
AK36d.V2 AK80d.V2 Issue 1 (3) 10/06/19