hit counter script
Lenovo ThinkSystem NE2572O Installation Manual

Lenovo ThinkSystem NE2572O Installation Manual

Rackswitch for network operating system
Table of Contents

Advertisement

Quick Links

Lenovo ThinkSystem NE2572O RackSwitch
Installation Guide
For Network Operating System

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo ThinkSystem NE2572O

  • Page 1 Lenovo ThinkSystem NE2572O RackSwitch Installation Guide For Network Operating System...
  • Page 2     Important Product Information: Before using this information and the product it supports, read Appendix B, “Notices“ of this manual. Also  read the product Warranty Information document and the Important Notices document included with the  product. First Edition (November 2018) © Copyright Lenovo 2018 Portions © Copyright IBM Corporation 2014. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant a General  Services Administration “GSA” contract, use, reproduction, or disclosure is subject to restrictions set forth  in Contract No. GS‐35F‐05925. Lenovo and the Lenovo logo are trademarks of Lenovo in the United States, other countries, or both.
  • Page 3: Table Of Contents

    ..... . . Safety Statements .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  9 Other Important Safety Notices .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    13 ThinkSystem NE2572O..... . 15 Port Configuration    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    15 Transceiver Configuration  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    15 Orientation, Airflow, and Redundancy.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    15...
  • Page 4 Korea Communications Commission (KCC) Statement .   .   .   .   .   .   .   .   .    79 Russia Electromagnetic Interference (EMI) Class A statement  .   .   .   .   .   .    79 People’s Republic of China Class A electronic emission statement  .   .   .   .    79 Taiwan Class A compliance statement  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    79 Taiwan BSMI RoHS declaration .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    80 Technical Specifications ..... 81 Physical Characteristics   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    82 Environmental Specifications .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    83 Lenovo NE2572O Installation Guide...
  • Page 5 Power Specifications    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    84 © Copyright Lenovo 2018 Contents...
  • Page 6 Lenovo NE2572O Installation Guide...
  • Page 7: Safety Information

    Safety Information Before installing this product, read the Safety Information. Antes de instalar este produto, leia as Informações de Segurança. Prije instalacije ovog produkta obavezno pročitajte Surgonosne Upute. Před instalací tohoto produktu si přečtěte příručku bezpečnostních instrukcí. Læs sikkerhedsforskrifterne, før du installerer dette produkt. Lees voordat u dit product installeert eerst de veiligheidsvoorschriften. Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information. Avant dʹinstaller ce produit, lisez les consignes de sécurité. Vor der Installation dieses Produkts die Sicherheitshinweise lesen.’ Πριν εγκαταστήσετε το προϊόν αυτό, διαβάστε τις Πληροφορίες ασφαλείας (safety information). A termék telepítés előtt olvassa el a Biztonsági előírásokat! Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Πред да инсталира овој продукт, прочитајте информацијата за безбедност. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Przed zainstalowaniem tego produktu, należy zapoznać się z książką “Informacje  dotyczace bezpieczeństwa” (Safety Information). Antes de instalar este produto, leia as Informações sobre Segurança. Перед установкой продукта прочтитe инcтрyкции по тexникe безопасности. © Copyright Lenovo 2018 Safety Information...
  • Page 8 Pred inštaláciou tohto zariadenia si prečítajte Bezpečnostné predpisy. Pred namestitvijo tega proizvoda preberite Varnostne informacije. Antes de instalar este producto, lea la información de seguridad.  Läs säkerhetsinformationen innan du installerar den här produkten. Bu ürünü kurmadan önce güvenlik bilgilerini okuyun. Youq mwngz yungh canjbinj neix gaxgonq, itdingh aeu doeg aen canjbinj soengq  cungj vahgangj ancien suisik. NE2572O Installation Guide...
  • Page 9: Safety Statements

    Safety Statements Important Each caution and danger statement in this document is labeled with a number. This  number is used to cross reference the English‐language caution or danger statement  with the translated versions of the caution or danger statement in the Safety  Information document. For example, if a caution statement is labeled “Statement 1,” translations for that  caution statement are in the Safety Information document under “Statement 1.” Be sure to read all caution and danger statements in this document before you  perform the procedures. Read any additional safety information that comes with  the system or optional device before you install the device. Following is a compilation of the statements found throughout this manual. Statement 3 CAUTION: When laser products (such as CD‐ROMs, DVD drives, fiber optic devices, or  transmitters) are installed, note the following:  Do not remove the covers. Removing the covers of the laser product could result  in exposure to hazardous laser radiation. There are no serviceable parts inside  the device. Use of controls or adjustments or performance of procedures other than those   specified herein might result in hazardous radiation exposure. DANGER   Some laser products contain an embedded Class 3A or Class 3B laser diode.  Note the following. Laser radiation when open. Do not stare into the beam, do not view directly  with optical instruments, and avoid direct exposure to the beam. Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil À Laser de Classe 1 © Copyright Lenovo 2018 Safety Information...
  • Page 10 Statement 5 CAUTION: The power control button on the device and the power switch on the power  supply do not turn off the electrical current supplied to the device. The device  also might have more than one power cord. To remove all electrical current from  the device, ensure that all power cords are disconnected from the power source.    Statement 8 CAUTION: Never remove the cover on a power supply or any part that has the following  label attached.   Hazardous voltage, current, and energy levels are present inside any component  that has this label attached. There are no serviceable parts inside these  components. If you suspect a problem with one of these parts, contact a service  technician. Statement 13 DANGER:   Overloading a branch circuit is potentially a fire hazard and a shock hazard  under certain conditions. To avoid these hazards, ensure that your system  electrical requirements do not exceed branch circuit protection requirements.  Refer to the information that is provided with your device for electrical  specifications. NE2572O Installation Guide...
  • Page 11 CAUTION: This product contains a Class 1M laser. Do not view directly with optical  instruments. Statement 26 CAUTION: Do not place any object on top of rack‐mounted devices.   Statement 31 DANGER      Electrical current from power, telephone, and communication cables is  hazardous. To avoid a shock hazard: Do not connect or disconnect any cables or perform installation,   maintenance, or reconfiguration of this product during an electrical storm.  Connect all power cords to a properly wired and grounded power source.  Connect to properly wired power sources any equipment that will be  attached to this product.  When possible, use one hand only to connect or disconnect signal cables.  Never turn on any equipment when there is evidence of fire, water, or  structural damage.  Disconnect the attached ac power cords, dc power sources, network  connections, telecommunications systems, and serial cables before you  open the device covers, unless instructed otherwise in the installation and  configuration procedures. Connect and disconnect cables as described in the following table when   you install, move, or open covers on this product or attached devices. © Copyright Lenovo 2018 Safety Information...
  • Page 12 For dc systems, ensure correct   cables. polarity of ‐48 V dc connections:  2.Remove the signal cables from the  RTN is + and ‐48 V dc is ‐. Earth  connectors. ground should use a two‐hole  lug for safety. 3.Remove all cables from the  4.Attach signal cables to other  devices. devices. 5.Connect power cords to their  sources. 6.Turn ON all the power sources. Statement 37 DANGER   When you populate a rack cabinet, adhere to the following guidelines:  Always lower the leveling pads on the rack cabinet.  Always install the stabilizer brackets on the rack cabinet.  Always install the heaviest devices in the bottom of the rack cabinet. Always install devices starting from the bottom of the rack cabinet.   Do not extend multiple devices from the rack cabinet simultaneously,  unless the rack‐mounting instructions direction you to do so. Multiple  devices extended into the service position can cause your rack cabinet to  tip. If you are not using the Lenovo 9308 rack cabinet, securely anchor the rack   cabinet to ensure its stability. NE2572O Installation Guide...
  • Page 13: Other Important Safety Notices

    Other Important Safety Notices This product is also designed for IT power distribution systems with  phase‐to‐phase voltage of 230V. This product is not intended for use in the direct field of view at visual display  workplaces. Machinenlärminformations‐Verordnung—3. GPSGV, der höchste Shalldruckpegel  beträgt 70 dB (A) oder weniger. © Copyright Lenovo 2018 Safety Information...
  • Page 14 NE2572O Installation Guide...
  • Page 15: Thinksystem Ne2572O

    Chapter 1. ThinkSystem NE2572O This Installation Guide provides information about the Lenovo RackSwitch Lenovo  ThinkSystem NE2572O RackSwitch (referred to as NE2572O throughout this  document). This Installation Guide provides information about the Lenovo ThinkSystem  NE2572O RackSwitch (referred to as NE2572O throughout this document). The NE2572O uses a wire‐speed, non‐blocking switching fabric that provides  simultaneous wire‐speed transport of multiple packets at low latency on all ports. Port Configuration The NE2572O contains the following ethernet ports: Forty‐eight 25 Gigabit Ethernet (GbE) Small Form Pluggable 28 (SFP28) ports   Six 100 GbE Quad Small Form Pluggable 28 (QSFP28) ports, each of which can  optionally be used as four 10GbE SPF+ ports, or four 25GbE SPF28 ports, or two  50GbE QSPF28 ports, or one 40GbE QSPF+ port Transceiver Configuration QSFP+ ports can be populated with optical QSFP+ modules or passive Direct‐Attach  Cables (DACs), including those that allow the port to be used as four 25 GbE SFP+  ports. Orientation, Airflow, and Redundancy The NE2572O is 1U in height and can be mounted horizontally or vertically,  depending on your application. Mounting options are available for a variety of rack  systems. For superior reliability, the NE2572O uses redundant, hot‐swap power supply  modules and six hot‐swap fan modules. Module options are available for  rear‐to‐front airflow. Management You can manage the switch through the local console port, or through a remote  network connection. © Copyright Lenovo 2018...
  • Page 16: Ne2572O Documentation

    NE2572O Documentation This Installation Guide provides information and instructions for installing the  NE2572O, updating the firmware, and solving problems. For other information  about configuration and management of the switch, refer to the documents  described in “Related Documentation” on page Notes:  The illustrations in this document might differ slightly from your hardware.  The console output described or referenced in this document might differ  slightly from that displayed by your system. Output varies according to the type  of Lenovo chassis and the firmware versions and options that are installed. Notices and Statements in this Document The following notices and statements are used in this document:   Note: These notices provide important tips, guidance, or advice. Important: These notices provide information or advice that might help you   avoid inconvenient or problem situations.  Attention: These notices indicate potential damage to programs, devices, or  data. An attention notice is placed just before the instruction or situation in  which damage could occur.  Caution: These statements indicate situations that can be potentially hazardous   to you. A caution statement is placed just before the description of a potentially  hazardous procedure step or situation.  Danger: These statements indicate situations that can be potentially lethal or  extremely hazardous to you. A danger statement is placed just before the  description of a potentially lethal or extremely hazardous procedure step or  situation. Related Documentation Additional or updated product documents may be available from the Lenovo ...
  • Page 17: Switch Components

    Chapter 2. Switch Components This chapter describes the NE2572O hardware components. © Copyright Lenovo 2018...
  • Page 18: Switch Unit

    Switch Unit The NE2572O is a 1U rack‐mountable GbE switch. You can mount the switch in  either the horizontal or vertical orientation. The following illustrations show the features on the front and rear of the switch. Figure 1. ThinkSystem NE2572O front panel  25 GbE SFP28 Ports Management Panel 100 GbE QSPF28 Ports Figure 2. ThinkSystem NE2572O management panel detail  Status Micro-USB LEDs Type A Port Reset Button RJ45 Management Port RJ45 Console Port Figure 3. ThinkSystem NE2572O rear panel  NE2572O Installation Guide...
  • Page 19: Management Panel

    To Switch RJ45 To PC Console Port Terminal RJ45-to-DB9 Serial Console Cable If using cables other than those from the included cable kit, ensure that they are  compatible with the port pin assignments shown in the following tables.   Table 1. Console cable RJ45 port connector pin assignments Pin Number Function RTS (Request To Send) DTR (Data Terminal Ready) TxD (Transmit Data) GND (Ground) GND (Ground) RxD (Receive Data) DSR (Data Set Ready) CTS (Clear To Send) © Copyright Lenovo 2018 Chapter 2: Switch Components...
  • Page 20: Rj45 Management Port

    RJ45 Management Port The RJ45 management port on the front panel supports 10/100/1000BASE‐T, in‐line  switch management. To attach an RJ45 connector to the switch, push the RJ45 cable connector into the  port connector until it clicks into place.   To disconnect the RJ45 cable, squeeze the release tab and gently pull the cable  connector out of the switch connector. RJ45 Management LEDs The RJ45 management port LEDs are oriented as shown in the following figure. Figure 5. RJ45 management port LEDs Link LED Speed LED Status LEDs for the RJ45 management port are described in the following table.   Table 2. RJ45 status LEDs behavior State Functional Meaning Link Flashing green Activity Steady green Link up No link Speed Steady green 100/1000 Mbps connection 10 Mbps connection or no link Reset Button The Reset button is recessed within a hole on the front panel. Use a straightened ...
  • Page 21: Micro-Usb Port

    Micro-USB Port The micro‐USB Type A port enables you to connect a USB drive to the switch. You  can copy files from the switch to the USB drive, or from the USB drive to the switch.  You can also start the switch using files on the USB drive. A micro‐USB Type A to USB Type A data cable is provided with switch. It can be  used to connect an USB drive to the switch. The supported file system formats for USB drives are FAT32 and NTFS (read‐only). Note: When using a NTFS formatted USB drive, copying operations are limited to  read‐only. Files can be copied from the USB drive to the switch, but copying files to  the NTFS formatted USB drive results in failure. © Copyright Lenovo 2018 Chapter 2: Switch Components...
  • Page 22: Switching Ports

    Switching Ports The NE2572O contains the following:  Forty‐eight 25 Gigabit Ethernet (GbE) Small Form Pluggable 28 (SFP28)  Six 100 GbE Quad Small Form Pluggable 28 (QSFP28) ports QSFP28 ports can be populated with optical QSFP28 modules or Direct‐Attach  Cables (DACs), including those that allow the port to be used as four 25 GbE SFP+  ports. SFP+ ports can be populated with optical or copper transceiver modules or  DACs. Note: The SFP28 ports (Ethernet ports 1‐48) must be configured in groups of four  (ports 1‐4, 5‐8, 9‐12, and so on), with each port in that group having the same port  speed (10 or 25 Gbps). Trying to configure the SFP28 ports as single ports or in  discrete ranges (for example, Ethernet 1/3,5,11‐15) result in error. The switching ports are described in the following sections. For information about  ports on the management panel, see “Management Panel” on page SFP28 Ports Forty‐eight 25GbE SFP28 ports are located on the front panel. For 10 GbE connections, SFP28 ports can be used with 10GbE SFP+ direct‐attached  copper (DAC) cables or 10 GbE SFP+ active optical cables (AOCs). For 25 GbE connections, SFP28 ports can be used with 25 GbE SFP28 DAC cables or  25 GbE SFP28 active optical cables. SFP28 LEDs Status LEDs for the SFP28 ports are described in the following table.   Table 3. SFP28 port status LED behavior State Functional Meaning Link Solid green Secure 25 Gbps connection or link Flashing green Packet transmitting or receiving on 25G connection...
  • Page 23: Qsfp28 Leds

    QSFP28 LEDs Status LEDs for the QSFP28 ports are described in the following table.   Table 4. QSFP28 port status LED behavior State Functional Meaning Link Steady white Secure 100 Gbps connection or link Flashing white Packet transmitting or receiving Steady blue Secure 40 Gbps connection or link Flashing blue Packet transmitting or receiving Solid amber Secure 25 Gbps connection or link Flashing amber Packet transmitting or receiving Solid green Secure 10/25 Gbps connection or link Flashing green Packet transmitting or receiving Light off Link down or port disabled © Copyright Lenovo 2018 Chapter 2: Switch Components...
  • Page 24: Rear Panel

    Rear Panel The rear panel is composed of the following components. Fans For cooling, the rear panel of the NE2572O has six bays for hot‐swap fan modules.  Six fan modules are required for redundancy. When six fan modules are used, if  there is a failure of one of the fans, the switch reports the condition, the other fans  continue to run, and the switch continues to operate normally. You can replace one failed hot‐swap fan module while the switch is operating. If a  second fan fails, the switch reports the condition and shuts down to prevent  overheating. Compatible fan options are listed in the Lenovo Networking Catalog. Fan operation and internal temperatures are monitored. If the air temperature  exceeds a desired threshold, the environmental monitor displays warnings. Note: If a fan fails, the maximum operating temperature drops from +40°C (104°F)  to +35°C (95°F). NE2572O Installation Guide...
  • Page 25: Power Supply

    CAUTION: The power control button on the device and the power switch on the power  supply do not turn off the electrical current supplied to the device. The device  also might have more than one power cord. To remove all electrical current from  the device, ensure that all power cords are disconnected from the power source.    Statement 31 DANGER   Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: Do not connect or disconnect any cables or perform installation,   maintenance, or reconfiguration of this product during an electrical storm.  Connect all power cords to a properly wired and grounded power source.  Connect to properly wired power sources any equipment that will be  attached to this product.  When possible, use one hand only to connect or disconnect signal cables.  Never turn on any equipment when there is evidence of fire, water, or  structural damage.  Disconnect the attached ac power cords, dc power sources, network  connections, telecommunications systems, and serial cables before you  open the device covers, unless instructed otherwise in the installation and  configuration procedures. Connect and disconnect cables as described in the following table when   you install, move, or open covers on this product or attached devices. © Copyright Lenovo 2018 Chapter 2: Switch Components...
  • Page 26    To Connect: To Disconnect: 1.Turn OFF all power sources and  1.Turn OFF all power sources and  equipment that is to be attached to  equipment that is to be attached to  this product. this product. For ac systems, remove all power   2.Attach signal cables to the  cords from the chassis power  product. receptacles or interrupt power at  the ac power distribution unit. 3.Attach power cords to the  For dc systems, disconnect dc   product. power sources at the breaker  For ac systems, use appliance  panel or by turning off the power   inlets. source. Then, remove the dc  cables. For dc systems, ensure correct   polarity of ‐48 V dc connections:  2.Remove the signal cables from the  RTN is + and ‐48 V dc is ‐. Earth  connectors. ground should use a two‐hole  lug for safety. 3.Remove all cables from the  4.Attach signal cables to other  devices. devices. 5.Connect power cords to their  sources.
  • Page 27: Installing Ne2572O Hardware And Options

    Chapter 3. Installing NE2572O Hardware and Options This chapter describes how to install the NE2572O hardware and options. The  following topics are covered:  “Before Installing the NE2572O” on page 28 How to record important product information  Tools required for installation  A list of items included in the package  Environmental requirements  Vital safety information   Installing the switch in one of the supported rack types “Installing the NE2572O in a Standard Equipment Rack” on page 33  “Installing the NE2572O in a Lenovo System x or Power Rack” on page 36   “Installing the Air‐Duct Option” on page 43 Note: For information on removing or replacing installed NE2572O components,  see Chapter 4, “Removing and Replacing Components“. © Copyright Lenovo 2018...
  • Page 28: Before Installing The Ne2572O

    Some of the product information labels may be hidden from view once the  NE2572O is installed. To prevent the need to remove the switch in order to read  required product information, locate and record the information shown on Table 5  prior to installation. Figure 6 contains examples of product information labels. Figure 6. Sample product labels from the switch   Note: These examples are to help locate and identify the information labels. The  actual labels and information for your specific switch may differ. The identification labels on the front, rear, and/or bottom of the NE2572O contain  the Machine Type‐Model (MTM) number, serial number, part number of the switch.  These labels also include the Media Access Control (MAC) address (on the rear  panel of unit) of the switch. Though helpful, the MAC address is not required for  opening a service call. Print this page and record product information below. Keep the information in a  safe place for future reference. You will need this information when you register the  switch or open a service call with Lenovo.   Table 5. Important product information Product Name ThinkSystem NE2572O Machine‐Type Model Serial Number Part Number Media Access Control  (MAC) address for switch MAC addresses for other  components NE2572O Installation Guide...
  • Page 29: Required Tools

     One RJ45 to DB9 console cable  One Micro‐USB Type A to USB Type A cable   One power cord retention bracket  One Important Notices document  One Warranty Information document For a list of compatible switch components and options (such as rack‐mounting kits,  modules, cords, and cables), see the Lenovo Networking Catalog. Environmental Requirements This section describes the basic environmental requirements for the NE2572O.  Make sure the location where you install the switch meets the following  requirements: Install the switch unit in a dry, clean, well‐ventilated area.   Provide adequate space in the front and back of the switch unit, to ensure proper  air flow.  Make sure that an adequate grounded power supply is within reach of the  switch unit.  Make sure that twisted‐pair cable is routed away from power lines, fluorescent  lighting fixtures and other sources of electrical interference. © Copyright Lenovo 2018 Chapter 3: Installing NE2572O Hardware and Options...
  • Page 30: Preventing Electric Shock

    Preventing Electric Shock This product does not contain any user‐serviceable parts. Do not remove the cover  of this device. The NE2572O AC power module is designed to work with single‐phase power  systems that have a grounded neutral conductor. For your safety, a power cord with  a ground attachment plug is available to order for use with this product. To avoid  electrical shock, always use an appropriate power cord and plug with a properly  grounded outlet. Power cords for this product that are used in the United States and Canada are  listed by Underwriterʹs Laboratories (UL) and certified by the Canadian Standards  Association (CSA). For units intended to be operated at 115 volts: Use a UL‐listed and CSA‐certified  cord set consisting of a minimum of 18 AWG, Type SVT or SJT, three‐conductor  cord, a maximum of 15 feet in length and a parallel blade, grounding‐type  attachment plug rated 15 amperes, 125 volts. For units intended to be operated at 230 volts (U.S. use): Use a UL‐listed and  CSA‐certified cord consisting of a minimum of 18 AWG, Type SVT or SJT,  three‐conductor cord, a maximum of 15 feet in length and a tandem blade,  grounding‐type attachment plug rated 15 amperes, 250 volts. For units intended to be operated at 230 volts (outside the U.S.): Use a cord set with  a grounding‐type attachment plug. The cord set should have the appropriate safety  approvals for the country in which the equipment will be installed. Power cords for this product for a specific country or region are usually available  only in that country or region. Power cord installation should also conform to the recommendations listed in  “Cabling Guidelines” on page NE2572O Installation Guide...
  • Page 31 For dc systems, disconnect dc   power sources at the breaker  For ac systems, use appliance   panel or by turning off the power  inlets. source. Then, remove the dc  For dc systems, ensure correct   cables. polarity of ‐48 V dc connections:  RTN is + and ‐48 V dc is ‐. Earth  2. Remove the signal cables from the  ground should use a two‐hole  connectors. lug for safety. 3. Remove all cables from the  4. Attach signal cables to other  devices. devices. 5. Connect power cords to their  sources. 6. Turn ON all the power sources. © Copyright Lenovo 2018 Chapter 3: Installing NE2572O Hardware and Options...
  • Page 32: Handling Static-Sensitive Devices

    Handling Static-Sensitive Devices Attention: Static electricity can damage the switch and other electronic devices. To  avoid damage, keep static‐sensitive devices in their static‐protective packages until  you are ready to install them. To reduce the possibility of electrostatic discharge, observe the following  precautions: Limit your movement. Movement can cause static electricity to build up around   you.  The use of a grounding system is recommended. For example, wear an  electrostatic‐discharge wrist strap, if one is available.  Handle the device carefully, holding it by its edges or its frame. Do not touch solder joints, pins, or exposed printed circuitry.   Do not leave the device where others can handle and damage it.  While the device is still in its static‐protective package, touch it to an unpainted  metal part of any unpainted metal surface on a grounded rack component in the  rack in which you are installing the device, for at least 2 seconds. This drains  static electricity from the package and from your body.  Remove the device from its package and install it directly into the switch  without setting it down. If it is necessary to set down the device, put it back into  its static‐protective package. Do not place the device on a switch cover or on a  metal surface.  Take additional care when you handle devices during cold weather. Heating  reduces indoor humidity and increases static electricity. Cabling Guidelines Make sure that all connection cables comply with the following recommendations:  Make sure that the cables and cabling components comply with industry  standards.  Dress and affix cables to the rack to minimize the stress on the I/O connectors, ...
  • Page 33: Installing The Ne2572O In A Rack

    Installing the NE2572O in a Standard Equipment Rack This section describes how to install the NE2572O in a standard 19‐inch equipment  rack using the mounting kit included with the switch. For information about  mounting the switch in other supported racks, see the appropriate section in this  chapter. The following parts are included in the standard mounting kit.   Table 6. 2-post rack mount kit parts Item number Description Quantity Mounting brackets M4 screws M6 screws M6 clip nuts M6 cage nuts Attention:  The rack‐mounting frame may be unable to support the weight of the  switch with only the front post mounting brackets (2‐post application). If the switch  has an undesirable amount of sag, it is recommended to use a 4‐post mounting kit. Attention:  For earthquake stability, mount the switch in a 4‐post rack. © Copyright Lenovo 2018 Chapter 3: Installing NE2572O Hardware and Options...
  • Page 34 Statement 26 CAUTION: Do not place any object on top of rack‐mounted devices.   To install the NE2572O in a standard equipment rack, complete the following steps: 1. Locate, record, and retain the product switch information in order to configure and  register your product. See “Before Installing the NE2572O” on page Note: If this switch is a replacement switch, copy the product information from the  original switch onto the RID label that is shipped with replacement switch and  affix the new label to the bottom of the new switch. 2. Attach a mounting bracket (Item 1) to each side of the switch with M4 screws  (Item 2). Torque the screws to approximately 2.0 newton‐meters (Nm) ± 0.1 Nm  (17.7 inch‐pounds).   NE2572O Installation Guide...
  • Page 35 3. From the front, slide the switch into the rack at the desired height. 4. Secure the switch unit to the rack posts with M6 screws (Item 3) and either clip nuts  (Item 4) or cage nuts (Item 5). Torque the screws to approximately 5.7 Nm ± 0.1 Nm  (50 inch‐pounds).     Connect all external cables in accordance with the “Cabling Guidelines” on  page Initialize the switch. See Chapter 5, “Initializing the NE2572O“, on page © Copyright Lenovo 2018 Chapter 3: Installing NE2572O Hardware and Options...
  • Page 36: Installing The Ne2572O In A Lenovo System X Or Power Rack

    Installing the NE2572O in a Lenovo System x or Power Rack This section describes how to install the NE2572O in a Lenovo System x or Power  4‐post rack, using the Lenovo Adjustable 19” 4‐Post Rail Kit. This kit must be purchased separately. It includes the following parts:   Table 7. Lenovo Adjustable 19” 4-Post Rail Kit parts Item number Description Quantity Switch front bracket M4 screws M6 screws M6 clip nuts M6 cage nuts M3.5 screws Rear mounting bracket Rear mounting bracket with cord exit Filler plate Note: When using a System x or Power 4‐post rack, the 4‐Post Rail Kit is  compatible with the optional air‐duct kit (available separately). See “Installing the  Air‐Duct Option” on page 43 for details.
  • Page 37 To install the NE2572O in a System x or Power rack, complete the following steps: 1. Locate, record, and retain the product switch information in order to configure and  register your product. See “Before Installing the NE2572O” on page Note: If this switch is a replacement switch, copy the product information from the  original switch onto the RID label that is shipped with replacement switch and  affix the new label to the bottom of the new switch. 2. Attach the front mounting brackets (Item 1) to each side of the switch with M4  screws (Item 2). Torque the screws to approximately 2.0 newton‐meters (Nm) ± 0.1  Nm (17.7 inch‐pounds).   © Copyright Lenovo 2018 Chapter 3: Installing NE2572O Hardware and Options...
  • Page 38 3. From the front, slide the switch into the rack at the desired height. 4. Secure the switch to the front rack posts with M6 screws (Item 3) and either clip  nuts (Item 4) or cage nuts (Item 5). Torque the screws to approximately 5.7 Nm ± 0.1  Nm (50 inch‐pounds).   5. Slide the rear mounting brackets (Item 7 and Item 8) into the slots available on the  front mounting brackets.    NE2572O Installation Guide...
  • Page 39 6. Attach the filler plate (Item 9) and rear mounting brackets to the rear rack posts  with M6 screws (Item 3), and either clip nuts (Item 4) or cage nuts (Item 5). Torque  the screws to approximately 5.7 Nm ± 0.1 Nm (50 inch‐pounds).   7. Secure the rear brackets to the front brackets with M3.5 screws (Item 6). Torque the  screws to approximately 0.5 Nm (4 inch‐pounds).   If installing the 1U air‐duct option, see the instruction on page Connect all external cables in accordance with the “Cabling Guidelines” on  page Initialize the switch. See Chapter 5, “Initializing the NE2572O“. © Copyright Lenovo 2018 Chapter 3: Installing NE2572O Hardware and Options...
  • Page 40: Installing The Ne2572O In A Lenovo Idataplex Rack

    Installing the NE2572O in a Lenovo iDataPlex Rack This section describes how to install the NE2572O in a Lenovo iDataPlex rack. The  iDataPlex mounting kit allows the switch to be mounted either horizontally or  vertically. The kit must be purchased separately. It includes the following parts:   Table 8. Lenovo Adjustable 19” 4-Post Rail Kit parts Item number Description Quantity Switch front brackets M4 screws M6 screws M6 clip nuts Switch rear brackets Rear alignment plates Attention:  The rack‐mounting frame may not be able to support the weight of the  networking switch with only the front post mounting brackets (2‐post application).  If the switch has an undesirable amount of sag, it is recommended to use a 4‐post  mounting kit. Attention:  For earthquake stability, mount the switch in a 4‐post rack. Statement 26 CAUTION: Do not place any object on top of rack‐mounted devices.  ...
  • Page 41 To install the NE2572O in an iDataPlex rack, complete the following steps: 1. Locate, record, and retain the product switch information in order to configure and  register your product. See “Before Installing the NE2572O” on page Note: If this switch is a replacement switch, copy the product information from the  original switch onto the RID label that is shipped with replacement switch and  affix the new label to the bottom of the new switch. 2. Attach front mounting brackets (Item 1) and rear mounting brackets (Item 5) to  each side of the switch with M4 screws (Item 2). Torque the screws to  approximately 2 newton‐meters (Nm) +/‐ 0.1 Nm (17.7 inch‐pounds).  3. From the front, slide the switch into the rack at the desired height. 4. Secure the switch to the front rack posts with M6 screws (Item 3), and clip nuts  (Item 4). Torque the screws to approximately 5.7 Nm +/‐ 0.1 Nm (50 inch‐pounds).  © Copyright Lenovo 2018 Chapter 3: Installing NE2572O Hardware and Options...
  • Page 42 5. Attach the rear alignment plate (Item 6) to the rear rack posts with M6 screws (Item  3), and clip nuts (Item 4). Torque the screws to approximately 5.7 Nm +/‐ 0.1 Nm (50  inch‐pounds).  If installing the 1U air‐duct option, see the instruction on page Connect all external cables in accordance with the “Cabling Guidelines” on  page Initialize the switch. See Chapter 5, “Initializing the NE2572O“. NE2572O Installation Guide...
  • Page 43: Installing The Air-Duct Option

    19” rack. The air‐duct option is only supported when the switch is installed on a 4‐post rack  mount kit basis. If the switch is installed on a rack using default 2‐post rack mount  kit, it will not support the air‐duct option. For information on removing an installed 1U air‐duct option, see “Removing the  Air‐Duct Option” on page 61.   The following table lists the parts included with the air‐duct option kit.   Table 9. Air-duct Option Kit parts Item Number Description Quantity Cable tie 1U Duct sleeve (long) Mounting bracket (left) Mounting bracket (right) Foam carrier assembly M3.5 screws Attention:  The rack‐mounting frame may not be able to support the weight of the  networking switch with only the front post mounting brackets (2‐post application).  If the switch has an undesirable amount of sag, it is recommended to use a 4‐post  mounting kit. Attention:  For earthquake stability, mount the switch in a 4‐post rack. © Copyright Lenovo 2018 Chapter 3: Installing NE2572O Hardware and Options...
  • Page 44 Statement 26 CAUTION: Do not place any object on top of rack‐mounted devices.   To install the 1U air‐duct option in a 19” rack, complete the following steps: 1. Loosen and remove the mounting screws from both sides of the mounting rail and  set them aside to reuse for securing the foam carrier in the next step. 2. Place the half shears on the rear side of the foam carriers and use the M3.5  mounting rail screws to secure the foam carrier assemblies snugly against the rear  of the NE2572O unit. Torque the screws to approximately 1.1 Nm ± 0.1 Nm (10  inch‐pounds).   Foam carrier snug against rear of unit Reuse mounting screws Half shear Mounting screws Note: There are additional M3.5 screws in the air‐duct assembly kit. NE2572O Installation Guide...
  • Page 45 3. Secure the air‐duct mounting bracket to the rails with M6 screws. Torque the  screws to approximately 5.7 Nm ± 0.1 Nm (50 inch‐pounds).  Air duct mounting bracket M6 screws M3.5 screws Note:  Reuse the original M6 screws used to fasten the 4‐post rack mounting  brackets to secure the air duct mounting brackets with 4‐post mounting brackets  together.  4. Secure the air‐duct mounting bracket to the rack chassis with M3.5 screws. Torque  the screws to approximately 1.1 Nm ± 0.1 Nm (10 inch‐pounds). 5. Plug the power cords into their respective NE2572O power connectors and using  tie wraps, secure the power cords to the mounting rails.   Power connection Tie wraps Tie wraps Power connection © Copyright Lenovo 2018 Chapter 3: Installing NE2572O Hardware and Options...
  • Page 46 6. Gently slide the air‐duct unit side flanges into the card guides until the unit is  seated firmly. Make sure that the foam strip is oriented on top.   Foam Card guides thumbscrews Side flanges 7. Secure the air‐duct unit to the air‐duct brackets with the two M4 thumbscrews. NE2572O Installation Guide...
  • Page 47: Installing A Qsfp28 Optical Transceiver

    Installing a QSFP28 Optical Transceiver The QSFP28 ports accept approved QSFP28 transceivers. The QSFP28 optical  transceiver provides an MTP cable connector for connecting to external ports. Statement 3 CAUTION: When laser products (such as CD‐ROMs, DVD drives, fiber optic devices, or  transmitters) are installed, note the following: Do not remove the covers. Removing the covers of the laser product could result   in exposure to hazardous laser radiation. There are no serviceable parts inside  the device.  Use of controls or adjustments or performance of procedures other than those  specified herein might result in hazardous radiation exposure. DANGER   Some laser products contain an embedded Class 3A or Class 3B laser diode.  Note the following. Laser radiation when open. Do not stare into the beam, do not view directly  with optical instruments, and avoid direct exposure to the beam. Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil À Laser de Classe 1 © Copyright Lenovo 2018 Chapter 3: Installing NE2572O Hardware and Options...
  • Page 48 To install a QSFP28 optical transceiver in a QSFP28 port, complete the following  steps. Note: To avoid damage to the cable or the QSFP28 transceiver, do not connect the  cable before you install the transceiver. 1. Remove the safety cap and pull the locking lever into the down (unlocked)  position. 2. Insert the transceiver into the port until it clicks into place. Use minimal pressure  when you insert the transceiver into the slot. Do not use excessive force when you  insert the transceiver or you might damage the transceiver or the QSFP28 slot. The transceiver has a mechanical guide key to prevent you from inserting the  transceiver in an incorrect orientation. 3. Pull up the locking lever to lock the transceiver into place.  Connect the fiber‐optic cable following the “Cabling Guidelines” on page 32.  To remove a QSFP28 optical transceiver, disconnect the fiber‐optic cable, and pull  down the locking lever to release the transceiver. After you remove the transceiver,  replace the safety cap. NE2572O Installation Guide...
  • Page 49: Removing And Replacing Components

    Chapter 4. Removing and Replacing Components This chapter describes how to remove NE2572O hardware components for  replacement. The following topics are covered:  Removing and replacing hot‐swap modules “Removing and Replacing a Power Supply Module” on page 50  “Removing and Replacing a Fan Module” on page 54  Removing the switch from one of the supported rack types  “Removing the NE2572O from a Standard Equipment Rack” on page 56  “Removing the NE2572O from a Lenovo System x or Power Rack” on page 57   “Removing the Air‐Duct Option” on page 61  “Replacing the NE2572O” on page 62 © Copyright Lenovo 2018...
  • Page 50: Removing And Replacing A Power Supply Module

    Removing and Replacing a Power Supply Module The rear panel of the NE2572O has two bays for hot‐swap power supply modules.  Two active power supply modules are required for load‐sharing and redundancy. If  one power supply module fails, you can replace it without powering off the switch  or disrupting switch functions. For proper airflow when operating the switch with only one power supply module,  the empty power supply bay must be closed by a blank power filler plate. NE2572O Installation Guide...
  • Page 51: Removing The Power Supply Module

    Removing the Power Supply Module Statement 5 CAUTION: The power control button on the device and the power switch on the power  supply do not turn off the electrical current supplied to the device. The device  also might have more than one power cord. To remove all electrical current from  the device, ensure that all power cords are disconnected from the power source.    To remove a hot‐swap power supply module, complete the following steps: 1. Remove the power cord from the module’s power connector. 2. Press the release latch of the power supply module, and slide the module out of the  bay.    Attention:  Do not leave the power‐supply bay empty for more than 90 seconds  while the switch is operating. Either replace the power supply module or install a  blank power filler plate. To return the component to customer service for replacement, see Appendix A,  “Getting Help and Technical Assistance“ to help you gather all the required  information that is necessary to return a component. After you remove the  component, securely pack the component for shipping. © Copyright Lenovo 2018 Chapter 4: Removing and Replacing Components...
  • Page 52: Replacing The Power Supply Module

    Replacing the Power Supply Module Statement 31 DANGER Electrical current from power, telephone, and communication cables is  hazardous. To avoid a shock hazard:  Do not connect or disconnect any cables or perform installation,  maintenance, or reconfiguration of this product during an electrical storm.  Connect all power cords to a properly wired and grounded power source.  Connect to properly wired power sources any equipment that will be  attached to this product. When possible, use one hand only to connect or disconnect signal cables.   Never turn on any equipment when there is evidence of fire, water, or  structural damage.  Disconnect the attached ac power cords, dc power sources, network  connections, telecommunications systems, and serial cables before you  open the device covers, unless instructed otherwise in the installation and  configuration procedures.  Connect and disconnect cables as described in the following table when  you install, move, or open covers on this product or attached devices. NE2572O Installation Guide...
  • Page 53 For dc systems, ensure correct   cables. polarity of ‐48 V dc connections:  2.Remove the signal cables from  RTN is + and ‐48 V dc is ‐. Earth  the connectors. ground should use a two‐hole  lug for safety. 3.Remove all cables from the  4.Attach signal cables to other  devices. devices. 5.Connect power cords to their  sources. 6.Turn ON all the power sources. To replace a hot‐swap power supply module, complete the following steps: 1. Select an empty power supply module bay on the rear of the switch. If the target  bay is protected by a blank power filler plate, remove the blank. 2. Insert the power supply module into the selected power‐supply bay and gently  push it into the slot until it latches. Each power supply module has a mechanical  guide key to prevent you from inserting the module incorrectly.   3. Connect the power cord to the power supply module and to an appropriate  universal grounded AC power source. 4. Make sure that the power supply module’s LEDs are green. © Copyright Lenovo 2018 Chapter 4: Removing and Replacing Components...
  • Page 54: Removing And Replacing A Fan Module

    Removing and Replacing a Fan Module The rear panel of the NE2572O has Six bays for hot‐swap fan modules. Six active fan  modules are required for redundancy. With active fan modules in all fan bays, if one fan fails, the switch will send an error  message and continue operation. You can then replace the failed fan without  powering off the switch or disrupting switch functions. If a second fan fails, the  switch will send another error message, write a log message to flash memory, and  shut down to prevent overheating. Removing the Fan Module To remove a hot‐swap fan module, complete the following steps: 1. Loosen the retainer screw. 2. Grasp the extractor handle and gently pull the fan module from the slot.   Retainer Screw Attention:  If the inlet air temperature is above 35°C (95°F) while the switch is in  operation, replace the fan module within five minutes to avoid overheating the  switch. To return the component to customer service for replacement, see Appendix A,  “Getting Help and Technical Assistance“ to help you gather all the required  information that is necessary to return a component. After you remove the  component, securely pack the component for shipping. NE2572O Installation Guide...
  • Page 55: Replacing The Fan Module

    Replacing the Fan Module To replace a hot‐swap fan module, complete the following steps: 1. Select an empty fan module bay on the rear of the switch. If the target bay is  covered by a blank fan filler plate, loosen the retainer screw and slide the filler plate  out of the slot. 2. Remove the new fan module from the antistatic shielded bag. 3. Slide the fan module into the card guides in the open slot and gently push it all the  way into the slot, so that it firmly engages with the connector (see the illustration).  Each fan module has a mechanical guide key to prevent you from inserting the  module incorrectly.  Retainer Screw 4. Tighten the retaining screw on the fan module. Torque the screw to approximately  0.25 Nm +/‐ 0.1 Nm (2 inch‐pounds). 5. Make sure that the fan module’s LED is lit. © Copyright Lenovo 2018 Chapter 4: Removing and Replacing Components...
  • Page 56: Removing The Ne2572O From A Standard Equipment Rack

    Removing the NE2572O from a Standard Equipment Rack This section describes how to remove the NE2572O from a standard 19‐inch  equipment rack. For information about removing the switch from other supported  racks, see the appropriate section in this chapter. To remove the NE2572O from a standard rack, complete the following steps: 1. Disconnect all external cables. 2. Loosen and remove M6 screws, washers, and clip nuts (or cage nuts) to release the  switch unit from the rack.   3. Slide the switch unit out of the rack. 4. Loosen and remove the M4 screws attaching the mounting bracket on each side of  the switch.    If replacing the unit with another NE2572O, see “Replacing the NE2572O” on  page NE2572O Installation Guide...
  • Page 57: Removing The Ne2572O From A Lenovo System X Or Power Rack

    Removing the NE2572O from a Lenovo System x or Power Rack This section describes how to remove the NE2572O from a Lenovo System x or  Power 4‐post rack.  To remove the NE2572O from a System x or Power rack, complete the following steps: 1. Disconnect all external cables. If the air‐duct option has been installed, remove it as described in “Removing the  Air‐Duct Option” on page 3. Loosen and remove M3.5 screws that secure the rear brackets to the front brackets. 4. Loosen and remove the M6 screws, and clip nuts (or cage nuts) that attach the filler  plate and rear mounting brackets to the rear rack posts.  5. Slide the rear mounting brackets out of their slots in the front mounting brackets.   © Copyright Lenovo 2018 Chapter 4: Removing and Replacing Components...
  • Page 58 6. Loosen and remove the M6 screws, and clip nuts (or cage nuts) connecting the front  mounting brackets to the front rack posts.   7. Slide the NE2572O unit out of the rack. 8. Loosen and remove the M4 screws that attach the front mounting brackets to each  side of the switch.   If replacing the unit with another NE2572O, see “Replacing the NE2572O” on  page NE2572O Installation Guide...
  • Page 59: Removing The Ne2572O From A Lenovo Idataplex Rack

    Removing the NE2572O from a Lenovo iDataPlex Rack This section describes how to remove the NE2572O from a Lenovo iDataPlex rack. To remove the NE2572O from an iDataPlex rack, complete the following steps: 1. Disconnect all external cables. If the 1U air‐duct option has been installed, remove it as described in “Removing  the Air‐Duct Option” on page 3. Loosen and remove the M6 washers, screws, and clip nuts that attach the alignment  plate.  4. Loosen and remove the M6 washers and screws that mount the switch into the  rack.  © Copyright Lenovo 2018 Chapter 4: Removing and Replacing Components...
  • Page 60 5. Slide the switch out of the rack. 6. Loosen and remove the M4 screws that attach front and rear mounting brackets to  each side of the switch.   If replacing the unit with another NE2572O, see “Replacing the NE2572O” on  page NE2572O Installation Guide...
  • Page 61: Removing The Air-Duct Option

    Removing the Air-Duct Option The NE2572O supports an optional 1U air duct to maximize air flow conditions in a  Lenovo Power Systems Group rack. To remove an installed 1U air‐duct option from a 19” rack, complete the following  steps. 1. Loosen the M4 thumbscrews securing the air‐duct unit to the mounting brackets. 2. Slide the 1U air‐duct unit out of the rack.   thumbscrews To return the component to customer service for replacement, see Appendix A,  “Getting Help and Technical Assistance“ to help you gather all the required  information. After you remove the component, securely pack it for shipping. For instructions to install a replacement air‐duct option, see “Installing the Air‐Duct  Option” on page © Copyright Lenovo 2018 Chapter 4: Removing and Replacing Components...
  • Page 62: Replacing The Ne2572O

    Replacing the NE2572O Preparing and Returning the NE2572O If replacing the NE2572O, remove all associated components and options according  to the instructions in this chapter. Remove and retain clips, cords, cables, modules,  caps or blanks, air‐duct option (if installed), and any mounting hardware. These  items can then be reinstalled on the replacement unit. When you remove the NE2572O from the rack, record the product Machine  Type‐Model (MTM) number and serial number to use for the replacement switch.  See “Before Installing the NE2572O” on page 28 to locate the product information  labels on the switch or through the switch firmware interface. To return the chassis to customer service for replacement, see Appendix A, “Getting  Help and Technical Assistance“ to help you gather all the required information that  is necessary to return a component. After you remove the NE2572O unit, securely  pack it for shipping. Replace power and fan modules. For details, see “Removing and Replacing a Power  Supply Module” on page 50 and “Removing and Replacing a Fan Module” on  page Install the replacement NE2572O hardware as directed in Chapter 3, “Installing  NE2572O Hardware and Options“). NE2572O Installation Guide...
  • Page 63: Initializing The Ne2572O

    Chapter 5. Initializing the NE2572O When you supply power to the NE2572O, the switch initializes automatically for  basic functions. Statement 5 CAUTION: The power control button on the device and the power switch on the power  supply do not turn off the electrical current supplied to the device. The device  also might have more than one power cord. To remove all electrical current from  the device, ensure that all power cords are disconnected from the power source.    © Copyright Lenovo 2018...
  • Page 64: Connecting To The Switch

    Connecting to the Switch Use the switch Command‐Line Interface (CLI) to perform additional configuration  tasks. You can access the CLI in any of the following ways:  Telnet connection over the network SSH connection over the network   Serial connection via the serial port on the switch (this option is always  available) When reloaded, the switch will boot in ONIE Install mode. Using SSH or Telnet You can access the switch CLI using a Telnet or a SSH client. Make sure ONIE  receives an IP address provided by the network’s DHCP server. To do so, please  check the DHCP client lease database (dhcpd.leases file). Once the connection is setup, no password is required. Use the following command to access the ONIE log file:  ONIE:~ # cat /var/log/onie.log Using the Serial Console Port You can access the switch CLI through the serial console port on the front panel of  the switch. This port uses RS‐232 serial communications. Use the console cable kit to  connect the serial console port to a terminal or a computer running a terminal  emulation program. The console port terminal‐emulation requirements are as follows:  Default baud rate = 115,200 bps   Character size = 8 characters ...
  • Page 65: Updating Firmware

    Updating Firmware If ONIE firmware updates are available, you can download them from the Lenovo  website. To check for firmware and documentation updates, go to the Lenovo  website: http://support.lenovo.com/ Note: Changes are made periodically to the Lenovo website. Procedures for  locating firmware and documentation might vary slightly from what is described  in this document. © Copyright Lenovo 2018 Chapter 5: Initializing the NE2572O...
  • Page 66: The Grub Menu

    The GRUB Menu The Lenovo ThinkSystem NE2572O RackSwitch uses the GNU GRUB bootloader. Welcome to GRUB! GNU GRUB version 2.00 +----------------------------------------------------------------------+ |ONIE +----------------------------------------------------------------------+ Use the ^ and v keys to select which entry is highlighted. Press enter to boot the selected OS, `e' to edit the commands before booting or `c' for a command-line. ESC to return previous menu.
  • Page 67: Getting Help And Technical Assistance

     Check for updated software, firmware, and operating‐system device drivers for  your Lenovo product. The Lenovo Warranty terms and conditions state that  you, the owner of the Lenovo product, are responsible for maintaining and  updating all software and firmware for the product (unless it is covered by an  additional maintenance contract). Your service technician will request that you  upgrade your software and firmware if the problem has a documented solution  within a software upgrade.  If you have installed new hardware or software in your environment, check the  Lenovo Support portal to make sure that the hardware and software is  supported by your product., and where you can check for information to help  you solve the problem.  Gather the following information to provide to the service technician. This data  will help the service technician quickly provide a solution to your problem and  ensure that you receive the level of service for which you might have contracted. Hardware and Software Maintenance agreement contract numbers, if   applicable Machine type number (if applicable–Lenovo 4‐digit machine identifier)  Model number  Serial number  Current system UEFI and firmware levels  Other pertinent information such as error messages and logs   Start the process of determining a solution to your problem by making the  pertinent information available to the service technicians. The IBM service  technicians can start working on your solution as soon as you have completed  and submitted an Electronic Service Request. © Copyright Lenovo 2018...
  • Page 68 You can solve many problems without outside assistance by following the  troubleshooting procedures that Lenovo provides in the online help or in the  Lenovo product documentation. The Lenovo product documentation also  describes the diagnostic tests that you can perform. The documentation for most  systems, operating systems, and programs contains troubleshooting procedures  and explanations of error messages and error codes. If you suspect a software  problem, see the documentation for the operating system or program. NE2572O Installation Guide...
  • Page 69: Notices

    Lenovo may have patents or pending patent applications covering subject matter  described in this document. The furnishing of this document does not give you any  license to these patents. You can send license inquiries, in writing, to: Lenovo (United States), Inc. 1009 Think Place ‐ Building One Morrisville, NC 27560 U.S.A. Attention: Lenovo Director of Licensing LENOVO PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF  ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED  TO, THE IMPLIED WARRANTIES OF NON‐INFRINGEMENT,  MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some  jurisdictions do not allow disclaimer of express or implied warranties in certain  transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors.  Changes are periodically made to the information herein; these changes will be  incorporated in new editions of the publication. Lenovo may make improvements  and/or changes in the product(s) and/or the program(s) described in this  publication at any time without notice. The products described in this document are not intended for use in implantation or  other life support applications where malfunction may result in injury or death to  persons. The information contained in this document does not affect or change  Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or  indemnity under the intellectual property rights of Lenovo or third parties. All  information contained in this document was obtained in specific environments and  is presented as an illustration. The result obtained in other operating environments  may vary. Lenovo may use or distribute any of the information you supply in any way it  believes appropriate without incurring any obligation to you. Any references in this publication to non‐Lenovo Web sites are provided for  convenience only and do not in any manner serve as an endorsement of those Web  sites. The materials at those Web sites are not part of the materials for this Lenovo  product, and use of those Web sites is at your own risk. © Copyright Lenovo 2018...
  • Page 70 Any performance data contained herein was determined in a controlled  environment. Therefore, the result obtained in other operating environments may  vary significantly. Some measurements may have been made on development‐level  systems and there is no guarantee that these measurements will be the same on  generally available systems. Furthermore, some measurements may have been  estimated through extrapolation. Actual results may vary. Users of this document  should verify the applicable data for their specific environment. NE2572O Installation Guide...
  • Page 71: Trademarks

    Trademarks Lenovo, the Lenovo logo, Flex System, System x, NeXtScale System, and  X‐Architecture are trademarks of Lenovo in the United States, other countries, or  both. Intel and Intel Xeon are trademarks of Intel Corporation in the United States, other  countries, or both. Internet Explorer, Microsoft, and Windows are trademarks of the Microsoft group  of companies. Linux is a registered trademark of Linus Torvalds. Other company, product, or service names may be trademarks or service marks of  others. © Copyright Lenovo 2018 Appendix B: Notices...
  • Page 72: Important Notes

    Important Notes Processor speed indicates the internal clock speed of the microprocessor; other  factors also affect application performance. CD or DVD drive speed is the variable read rate. Actual speeds vary and are often  less than the possible maximum. When referring to processor storage, real and virtual storage, or channel volume,  KB stands for 1,024 bytes, MB stands for 1,048,576 bytes and GB stands for  1,073,741,824 bytes. When referring to hard disk drive capacity or communications volume, MB stands  for 1,000,000 bytes and GB stands for 1,000,000,000 bytes. Total user‐accessible  capacity can vary depending on operating environments. Maximum internal hard disk drive capacities assume the replacement of any  standard hard disk drives and population of all hard‐disk‐drive bays with the  largest currently supported drives that are available from Lenovo. Maximum memory might require replacement of the standard memory with an  optional memory module. Each solid‐state memory cell has an intrinsic, finite number of write cycles that the  cell can incur. Therefore, a solid‐state device has a maximum number of write cycles  that it can be subjected to, expressed as total bytes written (TBW). A device that has  exceeded this limit might fail to respond to system‐generated commands or might  be incapable of being written to. Lenovo is not responsible for replacement of a  device that has exceeded its maximum guaranteed number of program/erase cycles,  as documented in the Official Published Specifications for the device. Lenovo makes no representations or warranties with respect to non‐Lenovo  products. Support (if any) for the non‐Lenovo products is provided by the third  party, not Lenovo. Some software might differ from its retail version (if available) and might not  include user manuals or all program functionality. NE2572O Installation Guide...
  • Page 73: Recycling Information

    Recycling Information Lenovo encourages owners of information technology (IT) equipment to  responsibly recycle their equipment when it is no longer needed. Lenovo offers a  variety of programs and services to assist equipment owners in recycling their IT  products. For information on recycling Lenovo products, go to: http://www.lenovo.com/recycling © Copyright Lenovo 2018 Appendix B: Notices...
  • Page 74: Particulate Contamination

    Particulate Contamination Attention: Airborne particulates (including metal flakes or particles) and reactive  gases acting alone or in combination with other environmental factors such as  humidity or temperature might pose a risk to the device that is described in this  document. Risks that are posed by the presence of excessive particulate levels or concentrations  of harmful gases include damage that might cause the device to malfunction or  cease functioning altogether. This specification sets forth limits for particulates and  gases that are intended to avoid such damage. The limits must not be viewed or  used as definitive limits, because numerous other factors, such as temperature or  moisture content of the air, can influence the impact of particulates or  environmental corrosives and gaseous contaminant transfer. In the absence of  specific limits that are set forth in this document, you must implement practices that  maintain particulate and gas levels that are consistent with the protection of human  health and safety. If Lenovo determines that the levels of particulates or gases in  your environment have caused damage to the device, Lenovo may condition  provision of repair or replacement of devices or parts on implementation of  appropriate remedial measures to mitigate such environmental contamination.  Implementation of such remedial measures is a customer responsibility.. Contaminant Limits Particulate • The room air must be continuously filtered with 40% atmospheric  dust spot efficiency (MERV 9) according to ASHRAE Standard 52.2 • Air that enters a data center must be filtered to 99.97% efficiency or  greater, using high‐efficiency particulate air (HEPA) filters that meet  MIL‐STD‐282. • The deliquescent relative humidity of the particulate contamination  must be more than 60% • The room must be free of conductive contamination such as zinc whis‐ kers. Gaseous • Copper: Class G1 as per ANSI/ISA 71.04‐1985 • Silver: Corrosion rate of less than 300 Å in 30 days 1 ...
  • Page 75: Telecommunication Regulatory Statement

    Telecommunication Regulatory Statement This product may not be certified in your country for connection by any means  whatsoever to interfaces of public telecommunications networks. Further  certification may be required by law prior to making any such connection. Contact a  Lenovo representative or reseller for any questions. © Copyright Lenovo 2018 Appendix B: Notices...
  • Page 76: Electronic Emission Notices

    Federal Communications Commission (FCC) Statement Note: This equipment has been tested and found to comply with the limits for a  Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are  designed to provide reasonable protection against harmful interference when the  equipment is operated in a commercial environment. This equipment generates,  uses, and can radiate radio frequency energy and, if not installed and used in  accordance with the instruction manual, may cause harmful interference to radio  communications. Operation of this equipment in a residential area is likely to cause  harmful interference, in which case the user will be required to correct the  interference at his own expense. Properly shielded and grounded cables and connectors must be used to meet FCC  emission limits. Lenovo is not responsible for any radio or television interference  caused by using other than recommended cables and connectors or by  unauthorized changes or modifications to this equipment. Unauthorized changes or  modifications could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the  following two conditions: (1) this device may not cause harmful interference, and  (2) this device must accept any interference received, including interference that  might cause undesired operation. Industry Canada Class A Emission Compliance Statement This Class A digital apparatus complies with Canadian ICES‐003. Avis de Conformité à la Réglementation d'Industrie Canada Cet appareil numérique de la classe A est conforme à la norme NMB‐003 du ...
  • Page 77: European Union - Compliance To The Electromagnetic Compatibility Directive

    Lenovo, Einsteinova 21, 851 01 Bratislava, Slovakia Warning: This is a Class A product. In a domestic environment this product may  cause radio interference in which case the user may be required to take adequate  measures. Germany Class A Statement Deutschsprachiger EU Hinweis: Hinweis für Geräte der Klasse A EU‐Richtlinie zur Elektromagnetischen  Verträglichkeit Dieses Produkt entspricht den Schutzanforderungen der EU‐Richtlinie 2014/30/EU  (früher 2004/108/EC) zur Angleichung der Rechtsvorschriften über die  elektromagnetische Verträglichkeit in den EU‐Mitgliedsstaaten und hält die  Grenzwerte der Klasse A der Norm gemäß Richtlinie. Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu  installieren und zu betreiben. Des Weiteren dürfen auch nur von der Lenovo  empfohlene Kabel angeschlossen werden. Lenovo übernimmt keine Verantwortung  für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung  der Lenovo verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern  ohne Empfehlung der Lenovo gesteckt/eingebaut werden. Deutschland: Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit von  Betriebsmittein  Dieses Produkt entspricht dem „Gesetz über die elektromagnetische Verträglichkeit  von Betriebsmitteln“ EMVG (früher „Gesetz über die elektromagnetische  Verträglichkeit von Geräten“). Dies ist die Umsetzung der EU‐Richtlinie 2014/30/EU  (früher 2004/108/EC) in der Bundesrepublik Deutschland. Zulassungsbescheinigung laut dem Deutschen Gesetz über die  elektromagnetische Verträglichkeit von Betriebsmitteln, EMVG vom 20. Juli 2007  (früher Gesetz über die elektromagnetische Verträglichkeit von Geräten), bzw.  der EMV EU Richtlinie 2014/30/EU (früher 2004/108/EC ), für Geräte der Klasse A. © Copyright Lenovo 2018 Appendix B: Notices...
  • Page 78: Japan Vcci Class A Statement

    Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das  EG‐Konformitätszeichen ‐ CE ‐ zu führen. Verantwortlich für die  Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo (Deutschland)  GmbH, Meitnerstr.  9, D‐70563 Stuttgart. Informationen in Hinsicht EMVG Paragraf 4 Abs. (1) 4: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A. Nach der EN 55022: „Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann  im Wohnbereich Funkstörungen verursachen; in diesem Fall kann vom Betreiber  verlangt werden, angemessene Maßnahmen durchzuführen und dafür  aufzukommen.“ Nach dem EMVG: „Geräte dürfen an Orten, für die sie nicht ausreichend entstört  sind, nur mit besonderer Genehmigung des Bundesministers für Post und  Telekommunikation oder des Bundesamtes für Post und Telekommunikation  betrieben werden. Die Genehmigung wird erteilt, wenn keine elektromagnetischen  Störungen zu erwarten sind.“ (Auszug aus dem EMVG, Paragraph 3, Abs. 4).  Dieses Genehmigungsverfahrenist nach Paragraph 9 EMVG in Verbindung mit der  entsprechenden Kostenverordnung (Amtsblatt 14/93) kostenpflichtig. Anmerkung: Um die Einhaltung des EMVG sicherzustellen sind die Geräte, wie in  den Handbüchern angegeben, zu installieren und zu betreiben. Japan VCCI Class A Statement This is a Class A product based on the standard of the Voluntary Control Council  for Interference (VCCI). If this equipment is used in a domestic environment, radio  interference may occur, in which case the user may be required to take corrective  actions. Japan Electronics and Information Technology Industries Association (JEITA) Statement Japan Electronics and Information Technology Industries Association (JEITA)  Confirmed Harmonics Guidelines (products less than or equal to 20 A per phase) Japan Electronics and Information Technology Industries Association (JEITA) ...
  • Page 79: Korea Communications Commission (Kcc) Statement

    Korea Communications Commission (KCC) Statement This is electromagnetic wave compatibility equipment for business (Type A). Sellers  and users need to pay attention to it. This is for any areas other than home. Russia Electromagnetic Interference (EMI) Class A statement People’s Republic of China Class A electronic emission statement Taiwan Class A compliance statement © Copyright Lenovo 2018 Appendix B: Notices...
  • Page 80: Taiwan Bsmi Rohs Declaration

    Taiwan BSMI RoHS declaration 設備名稱:三層交換器 ,型號 (型式) :NE2572O Equipment Name , Type Designation (Type) 單元 限用物質及其化學符號 Unit Restricted Substances and their Chemical Symbols 鉛 汞 鎘 六價鉻 多溴聯苯 多溴二苯醚 Mercury Cadmium Hexavalent  Polybrominated  Polybrominated  Lead (Pb) (Hg) (Cd) chromium biphenyls diphenyl ethers (PBDE) (PBB)
  • Page 81: Technical Specifications

    Appendix C. Technical Specifications The NE2572O technical specifications are described in the following sections. © Copyright Lenovo 2018...
  • Page 82: Physical Characteristics

    Physical Characteristics The physical characteristics of the NE2572O are listed in the following table.   Table 10. Physical characteristics Specification Physical characteristics Dimensions (H x W x D) 4.4 x 43.9 x 48.7cm (1.73 x 17.3 x 19.2 in) Weight 11.5 kg (25 lb) maximum Airflow Available options for rear to front, or front to rear airflow NE2572O Installation Guide...
  • Page 83: Environmental Specifications

    Environmental Specifications The environmental specifications for the NE2572O are listed in the following table.   Table 11. NE2572O environmental specifications Specification Measurement Temperature, ambient operating 0°C to +40°C (32° to 104°F) Temperature (one fan failure),  0°C to +40°C (32° to 104°F) operating Temperature, storage ‐40°C to +75°C (‐40° to 167°F) Relative humidity (non‐condensing),  10 to 90% operating Relative humidity (non‐condensing),  5 to 95% storage Altitude, operating  ‐60 m to +2000 m (‐196.85 to +6561.7 ft) Altitude, storage Acoustic noise Less than 90dB Heat dissipation 728 BTU/h (typical) 1267 BTU/h (maximum) © Copyright Lenovo 2018 Appendix C: Technical Specifications...
  • Page 84 Power Specifications The power specifications for the NE2572O are listed in the following table.   Table 12. NE2572O AC power specifications Specification Measurement Number of power supplies 2 (1+1 load sharing/redundant) AC‐input frequency (universal)  50–60 Hz AC‐input voltage (universal)  100–240 VAC AC inrush current 8.34 A @ 120VAC (typical) 17.9 A @ 230VAC (typical) AC‐input current (typical)  1.78 A (RMS) @ 120 VAC 0.90 A (RMS) @ 230 VAC AC‐input current (maximum)  3.10 A (RMS) @ 120 VAC 1.58 A (RMS) @ 230 VAC Power supply rated output power  770 W each (rear‐to‐front airflow) System power dissipation (typical)  214 W System power dissipation (maximum)  372 W DC‐output current (typical) 16 A @ 12 V NE2572O Installation Guide...

Table of Contents