Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMP
P
OR
R TA
TANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
TH
H E
P
P
RO
O DUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PE
E
RS
S ON
N AL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAFETY
Familiarise yourself with the applications, limitations and hazards of the air needle scaler.
WARNING! Ensure health & safety, local authority, and general workshop practice regulations are adhered to when using
this equipment.
WARNING! Disconnect the air needle scaler from the air supply before changing accessories or servicing.
Maintain the air needle scaler in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts
may be dangerous and will invalidate the warranty.
WARNING! Check correct air pressure is maintained and not exceeded. Recommend pressure is 90psi.
Keep the air hose away from heat, oil and sharp edges. Check the air hose for wear before each use and ensure that all connections
are tight and secure.
Only use needles which are specifi cally designed for use with an air needle scaler.
WARNING! Always wear approved safety eye/face shield, ear defenders, and hand protection when operating the air needle scaler.
A full range of personal safety equipment is available from your Sealey stockist.
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
Keep children and non-essential persons away from the working area.
DO NOT use the air needle scaler for a task it is not designed to perform.
DO NOT use the air needle scaler if damaged or thought to be faulty. (Contact Sealey service agent).
DO NOT use the air needle scaler unless you have been instructed in its use by a qualified person.
DO NOT carry the air needle scaler by the air hose, or yank the hose from the air supply.
DO NOT operate the air needle scaler if you are tired or under the influence of alcohol, drugs or intoxicating medication.
DO NOT carry the air needle scaler with your hand on the power trigger in order to avoid unintentional starting.
DO NOT direct the air from the air hose at yourself or others.
When not in use disconnect the air needle scaler from air supply and store in a safe, dry, childproof location.
DO NOT operate the air needle scaler near flammable substances or flammable containers.
Dress properly. Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery and contain long hair.
WARNING! Secure workpiece with clamps or a vice where practical.
DO NOT hold an unsecured workpiece in your hand.
WARNING! The warnings, cautions and instructions discussed in this instruction manual cannot cover all possible
conditions and situations that may occur. It must be understood that common sense and caution are factors which
cannot be built into this product, but must be applied by the operator.
2. INTRODUCTION
Pistol type scaler suitable for cleaning heavy paint and rust scale from metal surfaces. Removable needle head allows use as a standard air
hammer but requires additional chisel set and spring retainer (not included). Features variable speed trigger control. Spring retainer, needle
and chisel sets available separately.
3. SPECIFICATION
Model No: ................................................................... SA501
Air Consumption: ........................................................... 4cfm
Consumable Parts:
Replacement Needle Set (19pc) .............................. SA50.02
Optional Spring Retainer: ....................................... SA11R/17
Optional Chisel Sets: ........................AK50 (5pc), AK57 (7pc)
Inlet Size: ..................................................................1/4"BSP
Noise Power:........................................................... 111dB(A)
Noise Pressure: ...................................................... 100dB(A)
No-Load Speed: ...................................................... 4500bpm
Operating Pressure: ...................................................... 90psi
Stroke: ......................................................................... 43mm
Vibration: ..................................................................... 13m/s²
Uncertainty: ................................................................ 5.2m/s²
© Jack Sealey Limited
AIR NEEDLE SCALER - PISTOL TYPE
MODEL NO:
Wear protective
Wear ear
gloves
protection
Original Language Version
SA501
Wear a mask
fi g.1
SA501 Issue 1 28/01/22

Advertisement

loading

Summary of Contents for Sealey SA501

  • Page 1 AIR NEEDLE SCALER - PISTOL TYPE SA501 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. R TA TANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY.
  • Page 2 If the air needle scaler is unable to remove the residue after several attempts, do not continue. Use another method to remove the residue. 5.9. Disconnect the air needle scaler from the air supply after use, and store in a dry, safe, secure childproof location. SA501 Issue 1 28/01/22 Original Language Version © Jack Sealey Limited...
  • Page 3 See section 4.2. 6.4. LUBRICATION 6.4.1. Lubricate the air needle scaler daily, or before each use, with a few drops of Sealey Air Tool Oil dripped into the air inlet. 6.5. CLEANING 6.6. Clean the air needle scaler after use.