Accuracy with favourable conditions * | ± 2.0 mm / ± 0.08 in *** |
Accuracy with unfavourable conditions ** | ± 3.0 mm / ± 0.12 in *** |
Range with favourable conditions * | 0.2-30 m / 0.6-98 ft |
Range with unfavourable conditions ** | 0.2-20 m / 0.6-66 ft |
Smallest unit displayed | 1 mm / 0.04 in |
Laser class | 2 |
Laser type | 635 nm, < 1 mW |
Ø laser point at distances | 6 / 18 mm 10 / 30 m |
Protection class | IP54 |
Autom. laser switch off | after 90 s |
Autom. power switch-off | after 180 s |
Battery durability (2 x AAA) | up to 5000 measurements |
Dimension (H x D x W) | 115 x 53 x 25 mm 4.5 x 2.14 x 1 in |
Weight (with batteries) | 95 g / 3.4 oz |
Temperature range:
| -25 to 70°C -13 to 158°F 0 to 40°C 32 to 104°F |
* favourable conditions are: white and diffuse reflecting target (white painted wall), low background illumination and moderate temperatures.
** unfavourable conditions are: targets with lower or higher reflectivity or high background illumination or temperatures at the upper or lower end of the specified temperature range.
*** Tolerances apply from 0.2 m to 5 m with a confidence level of 95%.
With favourable conditions the tolerance may deteriorate by 0.1 mm/m for distances above 5 m.
With unfavourable conditions the tolerance may deteriorate by 0.15 mm/m for distances above 5 m.
If the message Error does not disappear after switching on the device repeatedly, contact the dealer.
If the message InFoappears with a number, press the Clear button and observe the following instructions:
No. | Cause | Correction |
204 | Calculation error | Perform measurement again. |
252 | Temperature too high | Let device cool down. |
253 | Temperature too low | Warm device up. |
254 | Battery voltage too low for measurements | Change batteries. |
255 | Received signal too weak, measuring time too long | Change target surface (e.g.white paper). |
256 | Received signal too high | Change target surface (e.g.white paper). |
257 | Too much background light | Shadow target area. |
258 | Measurement outside of measuring range | Correct range. |
260 | Laser beam interrupted | Repeat measurement. |
Wavelength | 635 nm |
Maximum radiant output power used for classification | 0.95 mW |
Pulse repetition frequency | 320 MHz |
Pulse duration | >400ps |
Beam divergence | 0.16 mrad x 0.6 mrad |
The person responsible for the instrument must ensure that all users understand these directions and adhere to them.
Responsibilities of the manufacturer of the original equipment:
Makita Corporation Anjo, Aichi 446-8502 Japan /
Makita, Jan-Baptist Vinkstraat 2, 3070, Belgium
Internet: www.makita.com
The company above is responsible for supplying the product, including the User Manual in a completely safe condition.
The company above is not responsible for third party accessories.
Responsibilities of the person in charge of the instrument:
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the LD030P that isn't answered in the manual? Leave your question here.