free stats
NEC SL 1100 Quick Start Manual

NEC SL 1100 Quick Start Manual

Hide thumbs Also See for SL 1100:

Advertisement

Quick Links

SL 1100
Quick Start
Help Guide
Table of Contents:
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for NEC SL 1100

  • Page 1 SL 1100 Quick Start Help Guide Table of Contents: - 1 -...
  • Page 2: Table Of Contents

    Confirming a system’s IP address: ..............................7 : ..................................7 EFAULT ETTINGS : ................................7 EFAULT TATION ETTINGS : ........................................7 SL 1100 MANUAL CROSS REFERENCE: ............................8 : ..................................8 ESKTOP UITE ANUAL & S : ................................8 EATURES PECIFICATIONS : ....................................
  • Page 3: Document Description

    Document Description This document is a quick reference for the base SL 1100 KSU’s connections, base default as well as cross reference for which manual to refer to. This document is not intended to replace other SL 1100 manuals. These instructions are for reference only. Do not install the system without first reading the Hardware & Features and Specifications Manuals.
  • Page 4: Sl1100 Base Ksu Connections

    SL1100 Base KSU Connections: Figure 1 SL1100 Base KSU Connections VOIP DB, Use this as the Network connection when installed. CPU Network Connection, Use this when VOIP DB is not installed. - 4 -...
  • Page 5 084M KSU Mother Board, 080E Digital Station Card (ESIU) or 008E Analog Station Card (SLIU.) ***Important: It is highly recommended once the SL 1100 is installed onsite and Analog Trunks are installed that you run the Side Tone Auto Setup program in program 90-68-01 from a telephone. See Side Tone Auto Setup note at the end of this document for this procedure.
  • Page 6: Programming Methods

    DHCP Client: By default the SL 1100 is enabled to receive its IP address, Subnet Mask & Default Gateway from the Network’s DHCP Server. If you need to statically assign the system’s IP address you should go to program 10-63 and set DHCP to 0 for No or disable, then reboot the system first.
  • Page 7: Other Important Ethernet Program Address

    • System will require a reboot before it will use any changes made to any 10-12 program. • When the VOIP DB is installed you should use the VOIP DB in place of the CPU Interface Card. You should never have both connected at the same time. •...
  • Page 8: Sl 1100 Manual Cross Reference

    There are unique SIP Trunk Manuals for each SIP Trunk Provider that has completed Trunk Manuals: inter-opt testing with NEC SL1100. Each SIP Trunk manual provides documentation of required Programming for the SL 1100 to work with that particular SIP Trunk provider as well as program examples. - 8 -...
  • Page 9: Side Tone Auto Setup For Analog Trunks

    This procedure should be run in the following cases: 1) Upon new install of a SL 1100 once the system is installed onsite with the Analog lines installed. 2) Anytime the system is moved to a new site, once the lines are re-installed at the new location.