hit counter script
Table of Contents

Advertisement

#SCAN
No.
Initial
setting
#SCAN SW
SW1 - SW50
#SCAN
001: - 023:
NUMERIC
024:
390
025:
026:
22
027: - 030:
031:
0
032:
115
033:
32
034:
32
035: - 036:
555
037: - 040:
041:
0
042:
219
043:
75
044:
75
045:
75
046:
75
047:
32
048:
32
049: - 053:
054:
32
055: - 192:
193:
0
194:
0
195:
0
196 - 212:
213:
8273
214:
8737
215:
9427
216 - 350:
Range setting
Explanation
Not used
Not used
300 to 450, one
CS scan position during ADF scanning.
unit=0.1mm
Not used
6 to 48, one
Distance from the standby position of CIS to the shading start
unit=0.1mm
point.
Not used
0 to 70, one
Vertical scan start position adjustment
unit=0.1mm
50 to 150, one
Horizontal scan start position adjustment
unit=0.1mm
0 to 32, one
Vertical scan magnification correction
unit=0.1%
0 to 32, one
Horizontal scan magnification correction
unit=0.1%
Reader motor speed adjustment
Not used
0 to 70, one
Vertical scan start position adjustment (scanning on ADF)
unit=0.1mm
170 to 270, one
Horizontal scan start position adjustment (scanning on ADF)
unit=0.1mm
0 to 200, one
Horizontal scan end position correction (copy)
unit=0.1mm
0 to 200, one
Horizontal scan end position correction (superfine)
unit=0.1mm
0 to 200, one
Horizontal scan end position correction (fine)
unit=0.1mm
0 to 200, one
Horizontal scan end position correction (standard)
unit=0.1mm
0 to 32, one
Vertical scan magnification correction (scanning on ADF)
unit=0.1%
0 to 32, one
Horizontal scan magnification correction (scanning on ADF)
unit=0.1%
Not used
0 to 32, one
Pickup motor speed correction (when the ADF is used)
unit=0.1%
Not used
0: LEGAL
ADF special paper, standardized size: LGL misidentification-
1: FOOLSCAP
ready
2: M_OFFICIO
3:
A_FOOLSCAP
4: FOLIO
5: G_LEGAL
6: A_OFFICIO
7: B_OFFICIO
0: LTR
ADF special paper, standardized size: LTR misidentification-
1: G_LTR
ready
2: A_LTR
0: LTR_R
ADF special paper, standardized size: LTR_R misidentification-
1: FOOLSCAP
ready
2: OFFICIO
3: E_OFFICIO
4: G_LTR_R
5: A_LTR_R
Not used
1 to 9999
XYZ correction value of (X) of standard white plate (equipped
with SEND functions)
1 to 9999
XYZ correction value of (Y) of standard white plate (equipped
with SEND functions)
1 to 9999
XYZ correction value of (Z) of standard white plate (equipped
with SEND functions)
Not used
Chapter 15
15-5

Advertisement

Table of Contents
loading