Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY. ! WARNING! It is the user's responsibility to read, understand and comply with the following:
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and
all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety
devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD
(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD together with portable products that are
plugged into an electrical supply not protected by an RCCB. If in doubt consult a professional electrician. You may obtain a Residual Current
Device by contacting your Sealey dealer. You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity At Work Act 1989 requires all portable electrical appliances, if used on a business premises, to be tested by
a qualified Electrician at least once a year by using a Portable Appliance Tester (PAT).
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance,
and the safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3.
Ensure the insulation on all cables and the product itself is safe before connecting to the mains power
supply. See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply, leads, plugs and all electrical connections for wear and damage,
especially power connections, to ensure that none are loose.
1.1.6. Important: Ensure the voltage marked on the product is the same as the electrical power supply
to be used, and check that plugs are fitted with the correct capacity fuse. A 13Amp plug may require
a fuse smaller than 13Amps for certain products (subject to 1.1.10. below) see fuse rating at right.
1.1.7. DO NOT pull or carry the powered appliance by its power supply lead.
1.1.8. DO NOT pull power plugs from sockets by the power cable.
1.1.9. DO NOT use worn or damage leads, plugs or connections. Immediately replace or have repaired by
a qualified Electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off
and fit a new plug according to the following instructions (discard old plug safely).
(UK only - see diagram at right). Ensure the unit is correctly earthed via a three-pin plug.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
After wiring, check there are no bare wires, that all wires have been correctly connected and that the wire restraint is tight.
Double insulated products are often fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always marked with
this symbol
. To re-wire, connect the brown & blue wires as indicated above. DO NOT connect the brown or blue to the earth terminal.
1.1.10. Cable extension reels. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD
fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the cable on the cable
reel is important. We recommend that at least 1.5mm
suitable for this product and for others that may be used in the other output sockets, we recommend the use of 2.5mm
1.2
GENERAL SAFETY
WARNING! Ensure health & safety, local authority, and general workshop practice regulations are adhered to when using this equipment.
!
Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the cleaning tank.
"
! WARNING! Disconnect the cleaning tank from the mains power before changing accessories, servicing or performing any maintenance.
" Maintain the cleaning tank in good condition (use an authorised service agent).
Replace or repair damaged parts. Use genuine parts only. Non authorised parts may be dangerous and will invalidate the warranty.
"
" Locate the cleaning tank in an adequate working area for its function, Ensure the washer is stood on a firm level surface. Keep area clean
and tidy and free from unrelated materials. Ensure the area is well ventilated and has adequate lighting.
" Keep the cleaning tank away from heat sources such as heater, sparks, open flames etc.
" Keep the cleaning tank clean. Remove and clean the filter regularly for best and safest performance.
" Ensure there are no flammable or combustible materials near the work area.
! WARNING! Always wear approved eye or face protection when operating the cleaning tank.
" Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery, and contain long hair.
" Wear appropriate protective clothing.
" Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.
" Keep children and unauthorised persons away from the working area.
" Avoid accidental starting of the pump by ensuring the unit is unplugged from the mains power when not in use.
" Incase of fire in parts unit, do not attempt to remove parts, or the tank. The lid is fusible and will automatically close to extinguish flames.
# DO NOT modify or jam the cleaning tank lid open, as this will make the fusible fire link inoperative which is dangerous practice and will
invalidate the warranty and your insurance.
" When cleaning parts ensure that nothing in the tank, including any parts basket, is in a position that would prevent the lid from
closing fully if and when the fusible link activates.
# DO NOT use any solvent with a flash point below 140
# DO NOT use the cleaning tank for any purpose other than for which it is designed.
# DO NOT use cleaning tank in wet or damp locations or areas where there is condensation.
# DO NOT use the cleaning tank where there are flammable liquids, solids or gases such as paint solvents, etc.
DO NOT allow untrained persons to operate the cleaning tank.
#
DO NOT over fill the cleaning tank with solvent.
#
INSTRUCTIONS FOR:
PARTS CLEANING TANK
Model:
section cable but to be absolutely sure that the capacity of the cable reel is
2
F. We recommend you use Sealey solvent, contact your local dealer for details.
O
SM40
Blue
Neutral
wire
FUSE RATING
THIS PRODUCT MUST BE FITTED
Yellow & & G G reen
Earth w w ire
Brown
Live
wire
wire
restraint
WITH A:
3 Amp FUSE
section cable.
2
SM40 - 2 - 240805

Advertisement

loading

Summary of Contents for Sealey SM40

  • Page 1 SM40 Model: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2 2. APPLICATION & SPECIFICATIONS The SM40 industrial cleaning tank re-circulates fluid through a replaceable filter element and directs it onto the workpiece through a flexible metal delivery nozzle. The tank is big enough to take large engine components for de-greasing.The tank lid is fitted with fusible link hinge that will automatically snap the lid shut in the event of a fire.