Page 1
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Cisco Nexus 3000 Series Hardware...
Page 2
OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks.
Command References Technical References Error and System Messages Obtaining Documentation and Submitting a Service Request Overview of the Cisco Nexus 3000 Series Switches C H A P T E R Cisco Nexus 3016 Switch Chassis for the Cisco Nexus 3016 Switch...
Page 4
Power Supply for the Cisco Nexus 3132Q Switch 1-18 Fan Tray for the Cisco Nexus 3132Q Switch 1-19 Transceiver and Cabling Options for the Cisco Nexus 3132Q Switch 1-20 Cisco Nexus 3172PQ Switch 1-21 Chassis for the Cisco Nexus 3172PQ Switch...
Page 5
A P P E N D I X Switch Specifications Environmental Specifications Power Specifications Cable and Connector Specifications A P P E N D I X Console Cable Console Port Supported Power Cords and Plugs Jumper Power Cord Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Page 6
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m LED Descriptions A P P E N D I X Chassis and Module LEDs for the Cisco Nexus 3000 Series Switches Chassis and Module LED Descriptions Power Supply Status...
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Preface This preface describes the audience, organization, and conventions of the Cisco Nexus 3000 Series Hardware Installation Guide. It also provides information on how to obtain related documentation.
Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla. SÄILYTÄ NÄMÄ OHJEET Cisco Nexus 3000 Series Hardware Installation Guide viii OL-25338-04...
Page 9
Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo. GUARDE ESTAS INSTRUÇÕES Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Page 10
Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning. SPARA DESSA ANVISNINGAR Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Page 11
Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler, der fulgte med denne enhed. GEM DISSE ANVISNINGER Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Page 12
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Cisco Nexus 3000 Series Hardware Installation Guide...
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Related Documentation Documentation for the Cisco Nexus 3000 Series Switch is available at the following URL: http://www.cisco.com/en/US/products/ps11541/tsd_products_support_series_home.html...
Cisco Nexus 3000 Series Verified Scalability Guide for Cisco NX-OS Release 5.0(3)U2(2) Installation and Upgrade Guides Cisco Nexus 3000 Series Hardware Installation Guide Regulatory Compliance and Safety Information for the Cisco Nexus 5000 Series, Cisco Nexus 3000 Series, and Cisco Nexus 2000 Series Licensing Guide...
Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html...
Page 16
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Cisco Nexus 3000 Series Hardware Installation Guide...
Cisco Nexus 3548 and Cisco Nexus 3524 Switches, page 1-26 Cisco Nexus 3016 Switch The Cisco Nexus 3016 switch is a 1 rack unit (RU) switch that supports 16 fixed 40-Gigabit Ethernet downlink (host-facing) and uplink (network-facing) ports, two fixed 100/1000 management ports, one RS-232 console port, and one USB port.
Fully populated with two power supplies and a fan tray, the switch weighs 20.5 pounds (9.3 kg) and can be easily installed by one or two people. Figure 1-1 shows the front of the Cisco Nexus 3016 chassis and identifies the components that you use to install and connect the chassis. Figure 1-2 shows the rear of the chassis and identifies the components that you use to install and connect the chassis.
40-Gigabit uplink or downlink ports (16) Status LED Grounding pad Ports for the Cisco Nexus 3016 Switch The Cisco Nexus 3016 switch chassis includes the following ports: 40-Gigabit Ethernet uplink or downlink ports (16 ports) • 100/1000 Ethernet management ports (2 ports) •...
Power Supply for the Cisco Nexus 3016 Switch The Cisco Nexus 3000 Series switch has two slots for power supplies that are initially installed with one or two AC or DC power supplies that have forward or reverse airflow for their cooling. The switch requires only one power supply for its operations, but you can include a second one for redundancy.
Fan Tray for the Cisco Nexus 3016 Switch The Cisco Nexus 3016 switch ships with one fan tray, which is the same fan tray used by the Cisco Nexus 3064 switch (part number N3K-C3064-FAN for forward airflow or N3K-C3064-FAN-B for reverse airflow).
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Cisco Nexus 3048 Switch The Cisco Nexus 3048 switch is a 1 rack unit (RU) switch that supports 48 fixed 10/100/1000 Ethernet downlink (server-facing) ports, four fixed 10-Gigabit Ethernet uplink (network-facing) ports, two fixed 100/1000 management ports, and one console port.
Page 23
Chapter 1 Overview of the Cisco Nexus 3000 Series Switches Cisco Nexus 3048 Switch S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
1- and 10-Gigabit Ethernet uplink ports (4) 10/100/1000 Ethernet downlink ports (48) Grounding pad Ports for the Cisco Nexus 3048 Switch The Cisco Nexus 3048 switch chassis includes the following ports: 10/100/1000 Ethernet downlink ports (48 ports) • 1- and 10-Gigabit Ethernet uplink ports •...
Power Supply for the Cisco Nexus 3048 Switch The Cisco Nexus 3000 Series switch has two slots for power supplies that are initially installed with one or two AC or DC power supplies that have forward or reverse airflow for their cooling. The switch requires only one power supply for its operations, but you can include a second one for redundancy.
Fan Tray for the Cisco Nexus 3048 Switch The Cisco Nexus 3048 switch ships with one fan tray, which provides forward airflow from the fan tray to the port connector end exhaust (spares part number N3K-C3048-FAN=) or reverse airflow from the port connectors end of the chassis to the fan tray for exhaust (spares part number N3K-C3048-FAN-B).
SFP-H10GB-ACU10M 10-Gigabit Ethernet transceiver connected to an active 10-meter copper cable Cisco Nexus 3064 Switch The Cisco Nexus 3064 is a 1 rack unit (RU) switch that supports 48 fixed 1- and 10-Gigabit Ethernet host ports, four fixed 40-Gigabit Ethernet network ports, two fixed 100/1000 management ports, and one console port.
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Chassis for the Cisco Nexus 3064 Switch The 1-RU Cisco Nexus 3064 chassis (part number N3K-C3064PQ-10GE or N3K-C3064PQ-10GX) is 1.72 inches (4.37 cm) high, 17.3 inches (43.9 cm) wide, and 19.7 inches (45.0 cm) deep. This switch is designed for 19-inch (48.3 cm) racks.
Chapter 1 Overview of the Cisco Nexus 3000 Series Switches Cisco Nexus 3064 Switch S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
Power Supply for the Cisco Nexus 3064 Switch The Cisco Nexus 3000 Series switch has two slots for power supplies that are initially installed with one or two AC or DC power supplies that have forward or reverse airflow for their cooling. The switch requires only one power supply for its operations, but you can include a second one for redundancy.
40-Gigabit copper cable, or four 10-Gigabit copper cables with SFP+ transceivers. Table 1-10 describes the QSFP+ transceivers and cable connections that you can use. Table 1-10 QSFP+ Transceivers and Cables Used with the Cisco Nexus 3064 Switch Part Number Transceivers and Cables QSFP-40G-SR4 40-Gigabit SR4 QSFP transceiver on both ends of an optical cable.
LX/LH Cisco Nexus 3132Q Switch The Cisco Nexus 3132Q Switch is a high-performance switch that is a member of the Cisco Nexus 3100 switches. The Nexus 3100 switches are second-generation Cisco Nexus 3000 series switches and offer improved port density, scalability, and features compared to the first-generation switches.
Chassis for the Cisco Nexus 3132Q Switch The 1-RU Cisco Nexus C3132Q chassis (part number N3K-C3132Q-40GE) is 1.72 inches (4.4 cm) high, 17.3 inches (43.9 cm) wide, and 19.7 inches (50.5 cm) deep. This switch is designed for 19-inch (48.3 cm) racks.
Power Supply for the Cisco Nexus 3132Q Switch The Cisco Nexus 3000 Series switch has two slots for power supplies that are initially installed with one or two AC or DC power supplies that have forward or reverse airflow for their cooling. The switch requires only one power supply for its operations, but you can include a second one for redundancy.
Fan Tray for the Cisco Nexus 3132Q Switch The Cisco Nexus C3132Q switch supports four (3+1) redundant fans, which provide either forward or reverse airflow for cooling. You can hot swap the fan tray during operations but must replace it within one minute.
Transceiver and Cabling Options for the Cisco Nexus 3132Q Switch The Cisco Nexus 3132Q has 32 QSFP+ ports. QSFP+ technology allows a smooth transition from 10 to 40 Gigabit Ethernet infrastructures in data centers. Each of the Cisco Nexus 3132Q switch’s QSFP+ ports can operate in either native 40 Gigabit Ethernet mode or 4 x 10 Gigabit Ethernet mode.
Cisco QSA Module Cisco Nexus 3172PQ Switch The Cisco Nexus 3172PQ Switch is a high-performance switch that is a member of the Cisco Nexus 3100 switches. The Nexus 3100 switches are second-generation Cisco Nexus 3000 series switches and offer improved port density, scalability, and features compared to the first-generation switches.
Page 38
Chapter 1 Overview of the Cisco Nexus 3000 Series Switches Cisco Nexus 3172PQ Switch S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
Power Supply for the Cisco Nexus 3172PQ Switch The Cisco Nexus 3000 Series switch has two slots for power supplies that are initially installed with one or two AC or DC power supplies that have forward or reverse airflow for their cooling. The switch requires only one power supply for its operations, but you can include a second one for redundancy.
Transceiver and Cabling Options for the Cisco Nexus 3172PQ Switch The Cisco Nexus 3172PQ supports a wide variety of 1, 10, and 40 Gigabit Ethernet connectivity options. 1 and 10 Gigabit Ethernet connectivity is achieved in the first 48 ports, and 40 Gigabit Ethernet connectivity is achieved using QSFP+ transceivers in the last 6 ports.
CVR-QSFP-SFP10G Cisco QSA Module For in-rack or adjacent-rack cabling, the Cisco Nexus 3172PQ supports SFP+ direct-attach 10 Gigabit Ethernet copper, an innovative solution that integrates transceivers with Twinax cables into an energy-efficient and low-cost solution. For longer cable runs, multimode and single-mode optical SFP+ transceivers are supported.
GE SFP, LC connector LX/LH transceiver (SMF) Cisco Nexus 3548 and Cisco Nexus 3524 Switches The Cisco Nexus 3548 is a 1 rack unit (RU) switch that supports 48 fixed 1- and 10-Gigabit Ethernet Small Form-Factor Pluggable (SFP+) ports, dual redundant, hot-swappable power supplies, four individual, redundant, hot-swappable fans, one 1-PPS timing port, two 10/100/1000 management ports, one console port, and one USB port.
Chassis for the Cisco Nexus 3548 Switch The 1-RU Cisco Nexus 3548 chassis (part number N3K-C3548P-10G) is 1.72 inches (4.37 cm) high, 17.3 inches (43.9 cm) wide, and 18.38 inches (46.7 cm) deep. This switch is designed for 19-inch (48.3 cm) racks.
Chapter 1 Overview of the Cisco Nexus 3000 Series Switches Cisco Nexus 3548 and Cisco Nexus 3524 Switches S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
Power Supply for the Cisco Nexus 3548 Switch The Cisco Nexus 3000 Series switch has two slots for power supplies that are initially installed with one or two AC or DC power supplies that have forward or reverse airflow for their cooling. The switch requires only one power supply for its operations, but you can include a second one for redundancy.
Port Connections for the Cisco Nexus 3548 Switch The Cisco Nexus 3548 supports a wide variety of 1 and 10 Gigabit Ethernet connectivity options. For in-rack or adjacent-rack cabling, the Cisco Nexus 3548 supports SFP+ direct-attach 10 Gigabit Ethernet copper, an innovative solution that integrates transceivers with Twinax cables into an energy-efficient and low-cost solution.
Page 47
10-Gigabit Ethernet transceiver connected to an active 7-meter copper cable SFP-H10GB-ACU10M 10-Gigabit Ethernet transceiver connected to an active 10-meter copper cable The Cisco Nexus 3548 is compatible with existing Gigabit Ethernet infrastructures. Both the uplink and downlink 10 Gigabit Ethernet interfaces can also operate in Gigabit Ethernet mode.
Page 48
Chapter 1 Overview of the Cisco Nexus 3000 Series Switches Cisco Nexus 3548 and Cisco Nexus 3524 Switches S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
Starting the Switch, page 2-17 Before you install, operate, or service the system, see the Regulatory Compliance and Safety Information Note for the Cisco Nexus 5000 Series, Cisco Nexus 3000 Series, and Cisco Nexus 2000 Series for important safety information. Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger.
Unpacking and Inspecting the Switch, page 2-5 • Installation Options with Racks and Cabinets The Cisco Nexus 3000 Series switches can be installed in the following types of racks using a rack-mount kit shipped with the switch: Open EIA rack •...
Lift the switch slowly, keeping your back straight. Lift with your legs, not with your back. Bend at • the knees, not at the waist. Installation Guidelines When installing the Cisco Nexus 3000 Series switch, follow these guidelines: • Record the information listed in Appendix E, “Site Planning and Maintenance Records”...
Avoid UPS types that use ferroresonant technology. These UPS types can become unstable Caution with systems such as the Cisco Nexus 3000 Series switches, which can have substantial current draw fluctuations because of fluctuating data traffic patterns. Ensure that circuits are sized according to local and national codes. For North America, the power •...
The airflow direction must be the same for all modules. Installing the Switch This section describes how to use the rack-mount kit to install the Cisco Nexus 3000 Series switch into a cabinet or rack that meets the requirements described in Appendix A, “Cabinet and Rack...
Page 54
(3 inches [7.6 cm] minimum) and module handles (1 inch [2.5 cm] minimum). Figure 2-2 Two Ways to Attach Rack-Mount Brackets and Guides on the Cisco Nexus 3000 Series Chassis Cisco Nexus 3000 Series Hardware Installation Guide...
Page 55
Chapter 2 Installing the Cisco Nexus 3000 Series Switches Installing the Switch S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
Page 56
Chapter 2 Installing the Cisco Nexus 3000 Series Switches Installing the Switch S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
Page 57
Chapter 2 Installing the Cisco Nexus 3000 Series Switches Installing the Switch S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
12-24 screws to 30 in-lb (3.39 · Grounding the Switch This section describes the need for system grounding for all of the Cisco Nexus 3000 Series switches and explains how to prevent damage from electrostatic discharge. This section includes the following topics: Proper Grounding Practices, page 2-11 •...
Chapter 2 Installing the Cisco Nexus 3000 Series Switches Grounding the Switch S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Proper Grounding Practices Grounding is one of the most important parts of equipment installation.
The system ground connection is required if this equipment is installed in a U.S. or European Central Office. • You do not need to power down the chassis because the Cisco Nexus 3000 Series switches are equipped with AC-input power supplies. Cisco Nexus 3000 Series Hardware Installation Guide...
Grounding the Cisco Nexus 3000 Series Chassis The chassis has a grounding pad with two threaded M4 holes for attaching a grounding lug. The system ground is located on the left side of the chassis (left of the front) on the Cisco Nexus 3000 Series switches.
Chapter 2 Installing the Cisco Nexus 3000 Series Switches Grounding the Switch S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
Page 63
ESD grounding straps are available with banana plugs, metal spring clips, or alligator clips. All • chassis from the Cisco Nexus 3000 Series switches are equipped with a banana plug connector (identified by the ground symbol next to the connector) somewhere on the front panel. We recommend that you use a personal ESD grounding strap equipped with a banana plug.
Page 64
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m To attach the ESD wrist strap to the system ground lug screw for any of the Cisco Nexus 3000 Series...
Caution between 1 and 10 megohm (Mohm). Starting the Switch This section provides instructions for powering up the Cisco Nexus 3000 Series switch and verifying the component installation. Note Do not connect the Ethernet port to the LAN until the initial switch configuration has been performed.
Page 66
Chapter 2 Installing the Cisco Nexus 3000 Series Switches Starting the Switch S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
Page 67
Components”). If it still does not operate correctly, contact your customer service representative for a replacement. If you purchased this product through a Cisco reseller, contact the reseller directly for technical Note support. If you purchased this product directly from Cisco, contact Cisco Technical Support at this URL: http://www.cisco.com/en/US/support/tsd_cisco_worldwide_contacts.html.
Page 68
Chapter 2 Installing the Cisco Nexus 3000 Series Switches Starting the Switch S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
C H A P T E R Connecting to the Network This chapter describes how to connect the following ports on a Cisco Nexus 3000 Series switch: Console port —A direct local management connection used to initially configure the switch •...
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Preparing for Network Connections When preparing your site for network connections to the Cisco Nexus 3000 Series switch, consider the following for each type of interface, and gather all the required equipment before connecting the ports: Cabling required for each interface type •...
Note emulation. The terminal emulation software (such as HyperTerminal or Procomm Plus) makes communication between the Cisco Nexus 3000 Series switch and a computer possible during setup and configuration. To connect the console port to a computer terminal, follow these steps:...
SFP+ transceivers on optical cables to make the 1- or 10-Gigabit Ethernet uplink connections. For the Cisco Nexus 3064 switch, you must use RJ-45 connectors on copper cables to make the downlink connections and SFP transceivers on copper or optical cables or SFP+ transceivers on optical cables to make the 1- or 10-Gigabit Ethernet uplink connections.
This section includes the following topics: Installing an Optical Cable into an SFP or SFP+ Transceiver, page 3-6 • Replacing an Optical Cable for an SFP or SFP+ Transceiver, page 3-6 • Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Caution If the cable does not install easily, ensure that it is correctly positioned before continuing. For instructions on verifying connectivity, see the appropriate Cisco Nexus 3000 Series CLI configuration guide. Replacing an Optical Cable for an SFP or SFP+ Transceiver When pulling an optical cable from a transceiver, grip the body of the connector.
Inspect routinely for dust and damage. If damage is suspected, clean and then inspect fiber ends • under a microscope to determine if damage has occurred. Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Page 76
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Cisco Nexus 3000 Series Hardware Installation Guide...
Removing an AC Power Supply Caution If you are using the Cisco Nexus 3000 Series switch with one power supply, removing the power supply causes the switch to shut down. If the power supply is functioning, you can install a new power supply in the second power supply slot (see the “Installing an AC Power Supply”...
Step 4 N2200-P-BLNK). Figure 4-1 Removing the Power Supply from the Cisco Nexus 3000 Series Switch Push thumb latch to the left and slide out to remove. 2 Slide in until the latch clicks to install. Installing an AC Power Supply To install a power supply, follow these steps: Ensure that the system (earth) ground connection has been made for the chassis.
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Depending on the outlet receptacle on your power distribution unit, you may need the optional Note jumper power cord to connect the Cisco Nexus 3000 Series switch to your outlet receptacle. See “Jumper Power Cord” section on page C-8.
The fan tray is designed to be removed and replaced while the system is operating without causing an electrical hazard or damage to the system if the replacement is performed within 1 minute. Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Installing a Fan Tray, page 4-6 • Figure 4-2 shows how to remove and install a fan tray for the Cisco Nexus 3000 Series switch. Figure 4-2 Fan Tray for the Cisco Nexus 3000 Series Switch Loosen captive screws and slide out to remove. 2 Slide in and tighten captive screws to install.
Verify that the LED is green. If the LED is not green, one or more fans are faulty. If this problem occurs, contact your customer service representative for a replacement part. If you purchased this product through a Cisco reseller, contact the reseller directly for technical support. Note If you purchased this product directly from Cisco, contact Cisco Technical Support at this URL: http://www.cisco.com/en/US/support/tsd_cisco_worldwide_contacts.html.
Standard 19-inch (48.3 cm) (four-post EIA cabinet or rack, with mounting rails that conform to • English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). See the “Requirements Specific to Perforated Cabinets” section on page A-2. Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m The cabinet or rack must also meet the following requirements: The minimum vertical rack space per Cisco Nexus 3000 Series switch chassis must be one RU (rack •...
To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack. Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Page 86
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Cisco Nexus 3000 Series Hardware Installation Guide...
Cisco Nexus 3548 1.72 in. (4.36 cm) 17.3 in. (43.9 cm) 18.38 in (46.7 cm) 17.4 lb (7.9 kg) 1. Fully configured weight—For the Cisco Nexus 3064, that includes two power supplies and one fan try. Environmental Specifications Table B-2 lists the environmental specifications for the Cisco Nexus 3000 Series switches.
0 to 10,000 feet (0 to 3050 m) Nonoperating (storage) –1000 to 30,000 feet (–304 to 15,150 m) Power Specifications This section describes the AC power specifications for the Cisco Nexus 3000 Series switches. Table B-3 lists the specifications for the AC power supply. Table B-3...
Page 89
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Table B-3 Specifications for the Cisco Nexus 3000 Series AC Power Supplies (continued) Property...
Page 90
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Cisco Nexus 3000 Series Hardware Installation Guide...
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m A P P E N D I X Cable and Connector Specifications This appendix provides cable and port specifications for all of the Cisco Nexus 3000 Series switches. This appendix includes the following sections: Console Port, page C-2 •...
Page 92
Note Only the regular power cords or jumper power cords provided with the switch are supported. Table C-1 lists the power cords for the Cisco Nexus 3000 Series switches and provides their lengths in feet and meters. Table C-1 Power Cords for the Cisco Nexus 3000 Series Switches...
Page 93
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m Table C-1 Power Cords for the Cisco Nexus 3000 Series Switches (continued) Length...
Page 94
Cordset rating 10A, 250V Plug: (2500 mm) EL 218 (CCEE GB2009) Connector: EL 701 (IEC60320/C13) Figure C-5 CAB-9K10A-EU Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Plug: M2511 Connector: VSCC15 Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Page 95
Connector: EL 701B Plug: (IEC60320/C13) EL 212 (SI-32) Figure C-8 CAB-9K10A-IT Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Plug: Connector I/3G C15M (CEI 23-16) (EN60320/C15 ) Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Page 96
Length: 2500mm Connector: EL 701C Plug: EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse Figure C-11 CAB-AC-250V/13A Cordset rating 13A, 250V (6.6 feet) (79±2m) Connector: Plug: EL 701 EL312MoldedTwistlock (IEC60320/C13) (NEMA L6-20) Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Page 98
Jumper Power Cord Figure C-16 shows the plug connector on the optional jumper power cord for the Cisco Nexus 3000 Series switches. This cable plugs into the power supply and the receptacle of a power distribution unit for a cabinet. This cable comes in 6- and 9-foot (2- and 3-meter) lengths.
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m A P P E N D I X LED Descriptions This appendix describes the conditions indicated by the chassis and module LEDs on the Cisco Nexus 3000 Series switches. This appendix includes the following sections: Chassis and Module LEDs for the Cisco Nexus 3000 Series Switches, page D-1 •...
LED Descriptions Chassis and Module LEDs for the Cisco Nexus 3000 Series Switches S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m...
“Power Supply Status” section on page D-3. Power Supply Status This section describes the power supply LED indicators for the Cisco Nexus 3000 Series switches. Table D-2 describes the status indicated by the two LEDs on each power supply. Table D-2...
Page 102
Blinking green Activity The Cisco Nexus 3548 switch uses the activity LED to indicate both status and activity. The LED is Off, Note if there is no cable attached or if the connection is off. The LED has a slow blink rate, if there is a link, but no activity.
S e n d d o c u m e n t c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m A P P E N D I X Site Planning and Maintenance Records This appendix provides log sheets that you can use to record information when installing a Cisco Nexus 3000 Series switch. This appendix includes the following sections: Site Preparation Checklist, page E-1 •...
Page 104
Distance limitations for signaling • Site wiring • levels • 1. Verify that the power supply installed in the chassis has a dedicated AC source circuit. 2. UPS = uninterruptible power supply. Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
E-2) to record contact and site information. Table E-2 Contact and Site Information Contact person Contact phone Contact e-mail Building/site name Data center location Floor location Address (line 1) Address (line 2) City State Zip code Country Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
E-3) to record information about the chassis and modules. Contract Number_______________________________________________ Chassis Serial Number___________________________________________ Product Number________________________________________________ Table E-3 Network-Related Information Switch IP address Switch IP netmask Hostname Domain name IP broadcast address Gateway/router address DNS address Modem telephone number Cisco Nexus 3000 Series Hardware Installation Guide OL-25338-04...
Page 110
(table) power supplies airflow direction connecting to AC power source 2-17 management ports connecting to DC power source 2-18 connecting LED descriptions D-2, D-3 locations locations Cisco Nexus 3016 Cisco Nexus 3000 Series Hardware Installation Guide IN-4 OL-25338-04...
Page 111
1-12, 1-13, 1-17, 1-18, 1-22, 1-27, 1-28 chassis switch installation Cisco Nexus 3016 equipment required Cisco Nexus 3048 guidelines fan tray screw torques power supply system 2-12 reverse airflow, set up temperature specifications Cisco Nexus 3000 Series Hardware Installation Guide IN-5 OL-25338-04...