Sign In
Upload
Manuals
Brands
Mitsubishi Electric Manuals
Inverter
FR-E740-095
Mitsubishi Electric FR-E740-095 Manuals
Manuals and User Guides for Mitsubishi Electric FR-E740-095. We have
5
Mitsubishi Electric FR-E740-095 manuals available for free PDF download: Instruction Manual, Installation Manualline
Mitsubishi Electric FR-E740-095 Instruction Manual (538 pages)
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 14.72 MB
Table of Contents
Table of Contents
11
1 Product Checking and Part Identification
17
Inverter Type
17
Description of the Case
18
Accessory
19
2 Installation
21
Removal and Reinstallation of the Front Cover
21
FR-E720S and FR-E740-016SC to FR-E740-170SC
21
FR-E740-230SC and FR-E740-300SC
22
Removal and Reinstallation of the Wiring Cover
24
Mounting
25
Enclosure Design
27
Inverter Installation Environment
27
Inverter Placement
31
3 Wiring
33
Inverter and Peripheral Devices
33
Peripheral Devices
35
Terminal Connection Diagramm
36
Main Circuit Connection
38
Specification of Main Circuit Terminals
38
Terminal Layout and Wiring
39
Control Circuit Specifications
46
Control Circuit Terminals
49
Wiring Instructions
54
Safety Stop Function
55
Changing the Control Logic
58
PU Connector
61
Connecting the Parameter Unit Using a Connection Cable
61
RS-485 Communication
62
USB Connector
63
Connection of Stand-Alone Option Units
64
Magnetic Contactors (MC)
64
Connection of a Dedicated External Brake Resistor FR-ABR
66
(FR-E720S-030SC or More, FR-E740-016SC or More)
66
Connection of a Brake Unit FR-BU2
69
Connection of the High Power Factor Converter FR-HC
72
Connection of the Power Regeneration Common Converter FR-CV
73
Connection of the Power Improving DC Reactor FFR-HEL-(H)-E
74
Installation of a Reactor
74
Electromagnetic Compatibility (EMC)
75
Leakage Currents and Countermeasures
75
Inverter-Generated Noises and Their Reduction Techniques
79
Power Supply Harmonics
82
Inverter-Driven 400V Class Motor
83
4 Operation
85
Precautions for Use of the Inverter
85
Failsafe of the System Which Uses the Inverter
87
Drive the Motor
90
Operation Panel
91
Parts of the Operation Panel
91
Basic Operation (Factory Setting)
93
Easy Operation Mode Setting (Easy Setting Mode)
94
Operation Lock
96
Monitoring of Output Current and Output Voltage
98
First Priority Monitor
98
Digital Dial Push
98
Change the Parameter Setting Value
99
Parameter Clear/All Parameter Clear
100
Initial Value Change List
101
5 Basic Settings
103
Simple Mode Parameter List
103
Overheat Protection of the Motor by the Inverter
104
When the Rated Motor Frequency Is 60Hz (Pr. 3)
106
Increase the Starting Torque (Pr. 0)
107
Limit the Maximum and Minimum Output Frequency (Pr. 1, Pr. 2)
109
Change the Acceleration/Deceleration Time (Pr. 7, Pr. 8)
111
Operation Mode (Pr. 79)
113
Large Starting Torque and Low Speed Torque Are Necessary
114
Control) (Pr. 71, Pr. 80, Pr. 81, Pr. 800)
114
To Exhibit the Best Performance of the Motor Performance
117
(Offline Auto Tuning) (Pr. 9, Pr. 71, Pr. 83, Pr. 84, Pr. 96)
117
PU Operation Mode
122
Set the Set Frequency to Operate
123
Use the Digital Dial Like a Potentiometer to Perform Operation
125
Use Switches to Give the Frequency Command (Multi-Speed Setting)
126
Perform Frequency Setting by Analog Voltage Input
128
Perform Frequency Setting by Analog Current Input
130
External Operation
132
Use the Set Frequency Set by PU (Pr. 79 = 3)
132
Use Switches to Give a Start Command and a Frequency Command
134
(Multi-Speed Setting) (Pr. 4 to Pr. 6)
134
Perform Frequency Setting by Analog Voltage Input
137
Change the Frequency (40Hz) of the Maximum Value of Potentiometer
140
Perform Frequency Setting by Analog Current Input
141
Change the Frequency (40Hz) of the Maximum Value of Potentiometer
143
6 Parameter
145
Parameter Overview
145
Control Mode
174
Change the Control Method (Pr. 80, Pr. 81, Pr. 800)
175
Adjust the Output Torque (Current) of the Motor
177
Manual Torque Boost (Pr. 0, Pr. 46)
177
Advanced Magnetic Flux Vector Control
180
General-Purpose Magnetic Flux Vector Control
183
Slip Compensation (Pr. 245 to Pr. 247)
185
Stall Prevention Operation
186
Limit the Output Frequency
194
Maximum and Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)
194
Avoid Mechanical Resonance Points (Frequency Jumps) (Pr. 31 to Pr. 36)
196
Set V/F Pattern
198
Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)
198
Load Pattern Selection (Pr. 14)
200
Frequency Setting by External Terminals
202
Multi-Speed Setting Operation
202
(Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
202
Jog Operation (Pr. 15, Pr. 16)
205
Remote Setting Function (Pr. 59)
209
Acceleration and Deceleration
213
Acceleration and Deceleration Time
213
Starting Frequency and Start-Time Hold Function (Pr. 13, Pr. 571)
217
Acceleration and Deceleration Pattern (Pr. 29)
219
Shortest Acceleration/Deceleration (Automatic Acceleration/Deceleration)
221
(Pr. 61 to Pr. 63, Pr. 292, Pr. 293)
221
Selection and Protection of a Motor
224
Motor Overheat Protection (Electronic Thermal O/L Relay) (Pr. 9, Pr. 51)
224
Applied Motor (Pr. 71, Pr. 450)
229
(Offline Auto Tuning) (Pr. 71, Pr. 80 to Pr. 84, Pr. 90 to Pr. 94, Pr. 96, Pr. 859)
232
Motor Brake and Stop Operation
242
DC Injection Brake (Pr. 10 to Pr. 12)
242
Selection of a Regenerative Brake (Pr. 30, Pr. 70)
245
Stop Selection (Pr. 250)
247
Stop-On Contact Control Function
249
Brake Sequence Function (Pr. 278 to Pr. 283, Pr. 292)
253
Function Assignment of External Terminals
258
Input Terminal Function Selection (Pr. 178 to Pr. 184)
258
Inverter Output Shutoff Signal (MRS Signal, Pr. 17)
261
Condition Selection of Function Validity by Second Function Selection Signal
263
(RT, Pr. 155)
263
Start Signal Selection (Terminal STF, STR, STOP, Pr. 250)
264
Output Terminal Function Selection (Pr. 190 to Pr. 192)
268
Detection of Output Frequency (SU, FU, Pr. 41 to Pr. 43)
273
Output Current Detection Function (Y12, Y13, Pr. 150 to Pr. 153)
275
Remote Output Function (REM, Pr. 495 to Pr. 497)
277
Monitor Display and Monitor Output Signals
280
Speed Display and Speed Setting (Pr. 37)
280
Monitor Display Selection of DU/PU and Terminal am
282
Reference of the Terminal am (Analog Voltage Output) (Pr. 55, Pr. 56)
290
Terminal am Calibration [Calibration Parameter Pr. 645, C1 (Pr. 901)]
292
Operation Selection at Power Failure
295
Automatic Restart
295
Power Failure-Time Deceleration-To-Stop Function (Pr. 261)
307
Operation Setting at Alarm Occurrence
311
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
311
Input/Output Phase Failure Protection Selection (Pr. 251, Pr. 872)
314
Earth (Ground) Fault Detection at Start (Pr. 249)
315
Energy Saving Operation
316
Optimum Excitation Control (Pr. 60)
316
Motor Noise, EMI Measures, Mechanical Resonance
317
PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240)
317
Speed Smoothing Control (Pr. 653)
318
Frequency Setting by Analog Input (Terminal 2, 4)
319
Analog Input Selection (Pr. 73, Pr. 267)
319
Input Filter Time Constant (Pr. 74)
324
Bias and Gain of Frequency Setting Voltage (Current)
325
[Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905)]
325
Misoperation Prevention and Parameter Setting Restriction
332
Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)
332
Parameter Write Selection (Pr. 77)
337
Reverse Rotation Prevention Selection (Pr. 78)
339
User Groups (Pr. 160, Pr. 172 to Pr. 174)
340
Password Function (Pr. 296, Pr. 297)
343
Selection of Operation Mode and Operation Location
348
Operation Mode Selection (Pr. 79)
348
Operation Mode at Power on (Pr. 79, Pr. 340)
360
Start Command Source and Frequency Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
362
Communication Operation and Setting
371
PU Connector
371
Initial Settings and Specifications of RS-485 Communication
376
Communication E²PROM Write Selection (Pr. 342)
382
Mitsubishi Inverter Protocol (Computer Link Communication)
383
Modbus-RTU Communication
402
USB Communication (Pr. 547, Pr. 548)
420
Special Operation
421
PID Control (Pr. 127 to Pr. 134)
421
Dancer Control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)
433
Droop Control (Pr. 286 to Pr. 287)
441
Regeneration Avoidance Function
442
Useful Functions
445
Cooling Fan Operation Selection (Pr. 244)
445
Display of the Life of the Inverter Parts (Pr. 255 to Pr. 259)
446
Maintenance Timer Alarm (Pr. 503, Pr. 504)
451
Current Average Value Monitor Signal (Pr. 555 to Pr. 557)
452
Free Parameters (Pr. 888, Pr. 889)
456
Setting for the Parameter Unit, Operation Panel
457
RUN Key Rotation Direction Selection (Pr. 40)
457
PU Display Language Selection (Pr. 145)
457
Operation Panel Frequency Setting/Key Lock Operation Selection (Pr. 161)
458
Magnitude of Frequency Change Setting (Pr. 295)
459
Buzzer Control (Pr. 990)
460
PU Contrast Adjustment (Pr. 991)
460
7 Troubleshooting
461
List of Alarm Display
462
Causes and Corrective Actions
464
Reset Method of Protective Function
478
LED Display
479
Check and Clear of the Fault History
480
Check First When You Have Troubles
482
Motor Does Not Start
482
Motor or Machine Generates Abnormal Noise
484
Inverter Generates Abnormal Noise
484
Motor Generates Heat Abnormally
485
Motor Rotates in Opposite Direction
485
Speed Greatly Differs from the Setting
485
Acceleration/Deceleration Is Not Smooth
486
Speed Varies During Operation
487
Operation Mode Is Not Changed Properly
488
Operation Panel Display Is Not Operating
488
Motor Current Is too Large
489
Speed Does Not Accelerate
490
Unable to Write Parameter Setting
491
Meters and Measuring Methods
492
Measurement of Powers
493
Measurement of Voltages and Use of PT
494
Measurement of Currents
494
Use of CT and Transducer
495
Measurement of Inverter Input Power Factor
495
Measurement of Converter Output Voltage (Across Terminals P/+ and N/-)
495
8 Maintenance and Inspection
497
Daily Inspection
497
Periodic Inspection
497
Daily and Periodic Inspection
498
Display of the Life of the Inverter Parts
500
Checking the Inverter and Converter Modules
501
Cleaning
502
Replacement of Parts
502
Inverter Replacement
506
Measurements on the Main Circuit
507
Insulation Resistance Test Using Megger
507
Pressure Test
507
Measurement of Voltages and Currents
508
A Appendix
511
Specifications
511
1-Phase, 200V Class
511
3-Phase, 400V Class
512
Common Specifications
513
Outline Dimension Drawings
515
FR-E720S-008SC to 030SC
515
FR-E720S-050SC and 080SC
516
FR-E720S-110SC and FR-E740-016SC to 095SC
517
FR-E740-120SC and 170SC
518
FR-E740-230SC and 300SC
518
Parameter Unit FR-PU07
519
Parameter Unit FR-PA07
520
Parameter List with Instruction Codes
521
Specification Change
531
SERIAL Number Check
531
Advertisement
Mitsubishi Electric FR-E740-095 Instruction Manual (335 pages)
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 22.84 MB
Table of Contents
Table of Contents
4
Product Checking and Parts Identification
11
Inverter and Peripheral Devices
12
Peripheral Devices
13
Removal and Reinstallation of the Cover
14
Front Cover
14
Wiring
14
Wiring Cover
16
Installation of the Inverter and Enclosure Design
17
Inverter Installation Environment
17
Cooling System Types for Inverter Panel
19
Inverter Placement
20
Wiring
22
Terminal Connection Diagram
23
Main Circuit Terminal Specifications
25
Specification of Main Circuit Terminal
25
Terminal Arrangement of the Main Circuit Terminal, Power Supply and the Motor Wiring
25
Cables and Wiring Length
27
Control Circuit Specifications
31
Control Circuit Terminal
31
Changing the Control Logic
34
Connection of Stand-Alone Option Unit
35
Wiring of Control Circuit
36
Safety Stop Function (Available Only for the Safety Stop Function Model)
40
Connection to the PU Connector
42
Connection of Stand-Alone Option Unit
44
Connection of a Dedicated External Brake Resistor (MRS Type, MYS Type, FR-ABR)
44
Connection of the Brake Unit (FR-BU2)
46
Connection of the High Power Factor Converter (FR-HC)
47
Installation of Power Factor Improving Reactor
47
Connection of the Power Regeneration Common Converter (FR-CV)
48
Connection of the DC Reactor (FR-HEL)
48
Precautions for Use of the Inverter
50
EMC and Leakage Currents
51
Leakage Currents and Countermeasures
51
EMC Measures
53
Power Supply Harmonics
55
Installation of Power Factor Improving Reactor
56
Power-OFF and Magnetic Contactor (MC)
57
Inverter-Driven 400V Class Motor
58
Precautions for Use of the Inverter
59
Failsafe of the System Which Uses the Inverter
61
Parameters
64
Operation Panel
65
Names and Functions of the Operation Panel
65
Basic Operation (Factory Setting)
66
Easy Operation Mode Setting (Easy Setting Mode)
67
Changing the Parameter Setting Value
68
Setting Dial Push
68
Parameter List
69
Control Mode
81
Changing the Control Method (Pr. 80, Pr. 81, Pr. 800)
82
Adjustment of the Output Torque (Current) of the Motor
83
Manual Torque Boost (Pr. 0, Pr. 46)
83
Advanced Magnetic Flux Vector Control (Pr. 71, Pr. 80, Pr. 81, Pr.89, Pr. 800)
85
General-Purpose Magnetic Flux Vector Control (Pr. 71, Pr. 80, Pr. 81, Pr. 800)
88
Slip Compensation (Pr. 245 to Pr. 247)
90
Stall Prevention Operation (Pr. 22, Pr. 23, Pr. 48, Pr. 66, Pr. 156, Pr. 157, Pr. 277)
91
Limiting the Output Frequency
95
Maximum/Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)
95
Avoiding Mechanical Resonance Points (Frequency Jumps) (Pr. 31 to Pr. 36)
96
V/F Pattern
97
Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)
97
Load Pattern Selection (Pr. 14)
99
Frequency Setting by External Terminals
101
Operation by Multi-Speed Operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
101
Jog Operation (Pr. 15, Pr. 16)
103
Remote Setting Function (Pr. 59)
105
Setting of Acceleration/Deceleration Time and Acceleration/ Deceleration Pattern
108
Setting of the Acceleration and Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147)
108
Starting Frequency and Start-Time Hold Function (Pr. 13, Pr. 571)
111
Acceleration/Deceleration Pattern (Pr. 29)
112
Shortest Acceleration/Deceleration (Automatic Acceleration/Deceleration)
113
(Pr. 61 to Pr. 63, Pr. 292, Pr. 293)
113
Selection and Protection of a Motor
115
Motor Overheat Protection (Electronic Thermal O/L Relay) (Pr. 9, Pr. 51)
115
Applied Motor (Pr. 71, Pr. 450)
117
Exhibiting the Best Performance for the Motor (Offline Auto Tuning) (Pr. 71, Pr. 80 to Pr. 84, Pr. 90 to Pr. 94, Pr. 96, Pr. 859)
119
Motor Brake and Stop Operation
127
DC Injection Brake (Pr. 10 to Pr. 12)
127
Selection of a Regenerative Brake (Pr. 30, Pr. 70)
129
Stop Selection (Pr. 250)
131
Stop-On Contact Control Function (Pr. 6, Pr. 48, Pr. 270, Pr. 275, Pr. 276)
132
Brake Sequence Function (Pr. 278 to Pr. 283, Pr. 292)
134
Function Assignment of External Terminal and Control
138
Input Terminal Function Selection (Pr. 178 to Pr. 184)
138
Inverter Output Shutoff Signal (MRS Signal, Pr. 17)
140
Condition Selection of Function Validity by Second Function Selection Signal (RT)
141
Start Signal Operation Selection (STF, STR, STOP Signal, Pr. 250)
142
Output Terminal Function Selection (Pr. 190 to Pr. 192)
144
Detection of Output Frequency (SU, FU Signal, Pr. 41 to Pr. 43)
148
Output Current Detection Function (Y12 Signal, Y13 Signal, Pr. 150 to Pr. 153)
149
Remote Output Selection (REM Signal, Pr. 495 to Pr. 497)
151
Monitor Display and Monitor Output Signal
152
Speed Display and Speed Setting (Pr. 37)
152
Monitor Display Selection of DU/PU and Terminal am (Pr. 52, Pr.158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564)
153
Reference of the Terminal am (Analog Voltage Output) (Pr. 55, Pr. 56)
158
Terminal am Calibration (Calibration Parameter Pr. 645, C1 (Pr.901))
159
Operation Selection at Power Failure and Instantaneous Power Failure
161
Automatic Restart after Instantaneous Power Failure/Flying Start (Pr. 30, Pr. 57, Pr. 58, Pr. 96, Pr. 162, Pr. 165, Pr. 298, Pr. 299, Pr. 611)
161
Power-Failure Deceleration Stop Function (Pr. 261)
167
Operation Setting at Fault Occurrence
169
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
169
Input/Output Phase Loss Protection Selection (Pr. 251, Pr. 872)
171
Earth (Ground) Fault Detection at Start (Pr. 249)
171
Energy Saving Operation
172
Optimum Excitation Control (Pr. 60)
172
Motor Noise, EMI Measures, Mechanical Resonance
173
PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240)
173
Speed Smoothing Control (Pr. 653)
174
Frequency Setting by Analog Input (Terminal 2, 4)
175
Analog Input Selection (Pr. 73, Pr. 267)
175
Response Level of Analog Input and Noise Elimination (Pr. 74)
177
Bias and Gain of Frequency Setting Voltage (Current) (Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905))
178
Misoperation Prevention and Parameter Setting Restriction
183
Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)
183
Parameter Write Disable Selection (Pr. 77)
183
Parameter Write Disable Selection (Pr. 77)
186
Reverse Rotation Prevention Selection (Pr. 78)
187
Extended Parameter Display and User Group Function (Pr. 160, Pr. 172 to Pr. 174)
187
Password Function (Pr. 296, Pr. 297)
190
Selection of Operation Mode and Operation Location
193
Operation Mode Selection (Pr. 79)
193
Operation Mode at Power-ON (Pr. 79, Pr. 340)
193
Operation Mode at Power-ON (Pr. 79, Pr. 340)
203
Start Command Source and Frequency Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
204
Communication Operation and Setting
210
Wiring and Configuration of PU Connector
210
Initial Settings and Specifications of RS-485 Communication (Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549)
213
Operation Selection at Communication Error Occurrence (Pr. 121, Pr. 122, Pr. 502)
214
Communication EEPROM Write Selection (Pr. 342)
217
Mitsubishi Inverter Protocol (Computer Link Communication)
218
Modbus-RTU Communication Specifications (Pr. 117, Pr. 118, Pr. 120, Pr. 122, Pr. 343, Pr. 502, Pr. 549)
231
Modbus-RTU Communication Specifications
231
USB Communication (Pr. 547, Pr. 548)
244
Special Operation and Frequency Control
245
PID Control (Pr. 127 to Pr. 134)
245
Dancer Control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)
252
Droop Control (Pr. 286 to Pr. 287)
259
Regeneration Avoidance Function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)
260
Useful Functions
262
Cooling Fan Operation Selection (Pr. 244)
262
Display of the Life of the Inverter Parts (Pr. 255 to Pr. 259)
263
Maintenance Timer Alarm (Pr. 503, Pr. 504)
267
Current Average Value Monitor Signal (Pr. 555 to Pr. 557)
268
Free Parameter (Pr. 888, Pr. 889)
270
Setting from the Parameter Unit and Operation Panel
271
RUN Key Rotation Direction Selection (Pr. 40)
271
PU Display Language Selection(Pr.145)
271
Operation Panel Frequency Setting/Key Lock Operation Selection (Pr. 161)
272
Magnitude of Frequency Change Setting (Pr. 295)
274
Buzzer Control (Pr. 990)
275
PU Contrast Adjustment (Pr. 991)
275
Parameter Clear/ All Parameter Clear
276
Initial Value Change List
277
Check and Clear of the Faults History
278
Troubleshooting
281
Reset Method of Protective Function
282
List of Fault or Alarm Indications
283
Causes and Corrective Actions
284
Correspondences between Digital and Actual Characters
294
Check First When You Have a Trouble
295
Motor Does Not Start
295
Motor or Machine Is Making Abnormal Acoustic Noise
297
Inverter Generates Abnormal Noise
297
Motor Generates Heat Abnormally
297
Motor Rotates in the Opposite Direction
298
Speed Greatly Differs from the Setting
298
Acceleration/Deceleration Is Not Smooth
298
Speed Varies During Operation
299
Operation Mode Is Not Changed Properly
299
Operation Panel Display Is Not Operating
300
Motor Current Is too Large
300
Speed Does Not Accelerate
301
Unable to Write Parameter Setting
301
Precautions for Maintenance and Inspection
304
Inspection Items
304
Daily Inspection
304
Periodic Inspection
304
Daily and Periodic Inspection
305
Display of the Life of the Inverter Parts
306
Checking the Inverter and Converter Modules
307
Cleaning
308
Replacement of Parts
308
Inverter Replacement
311
Measurement of Main Circuit Voltages, Currents and Powers
312
Measurement of Powers
314
Measurement of Voltages and Use of PT
314
Measurement of Currents
315
Use of CT and Transducer
315
Measurement of Inverter Input Power Factor
315
Measurement of Converter Output Voltage (Across Terminals P/+ and N/-)
315
Insulation Resistance Test Using Megger
316
Pressure Test
316
Specifications
317
Rating
318
Common Specifications
320
Outline Dimension Drawings
321
Appendix
327
Appendix 1 for Customers Who Are Replacing the Conventional Model with this Inverter
328
Appendix 1-1 Replacement of the FR-E500 Series
328
Appendix 2 Specification Change
330
Appendix 2-1 SERIAL Number Check
330
Appendix 2-2 Changed Functions
330
Appendix 3 Index
331
Mitsubishi Electric FR-E740-095 Instruction Manual (312 pages)
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 15.72 MB
Table of Contents
Table of Contents
5
Product Checking and Parts Identification
13
Inverter and Peripheral Devices
14
Peripheral Devices
15
Removal and Reinstallation of the Cover
16
Front Cover
16
Wiring
16
Wiring Cover
17
Installation of the Inverter and Enclosure Design
18
Inverter Installation Environment
18
Cooling System Types for Inverter Panel
20
Inverter Placement
21
Wiring
24
Terminal Connection Diagram
25
Main Circuit Terminal Specifications
26
Specification of Main Circuit Terminal
26
Terminal Arrangement of the Main Circuit Terminal, Power Supply and the Motor Wiring
26
Main Circuit Terminal Specifications
27
Cables and Wiring Length
28
Control Circuit Specifications
31
Standard Control Circuit Terminal
31
Connection of Stand-Alone Option Unit
31
Changing the Control Logic
34
Wiring of Control Circuit
36
Wiring Instructions
37
Connection to the PU Connector
38
Connection of Stand-Alone Option Unit
40
Connection of a Dedicated External Brake Resistor (MRS Type, MYS Type, FR-ABR) (FR-E720-030 or More, FR-E740-016 or More)
40
Connection of the Brake Unit (FR-BU2)
42
Connection of the High Power Factor Converter (FR-HC)
43
Installation of Power Factor Improving Reactor
43
Connection of the Power Regeneration Common Converter (FR-CV)
44
Connection of a DC Reactor (FR-HEL)
44
Precautions for Use of the Inverter
46
EMC and Leakage Currents
47
Leakage Currents and Countermeasures
47
EMC Measures
49
Power Supply Harmonics
51
Installation of Power Factor Improving Reactor
52
Power-Off and Magnetic Contactor (MC)
53
Inverter-Driven 400V Class Motor
54
Precautions for Use of the Inverter
55
Failsafe of the System Which Uses the Inverter
57
Parameters
60
Operation Panel
61
Names and Functions of the Operation Panel
61
Basic Operation (Factory Setting)
62
Easy Operation Mode Setting (Easy Setting Mode)
63
Change the Parameter Setting Value
64
Setting Dial Push
64
Parameter List
65
Control Mode
74
Change the Control Method (Pr. 80, Pr. 81, Pr. 800)
78
Adjust the Output Torque of the Motor (Current)
79
Manual Torque Boost (Pr. 0, Pr. 46)
79
Advance Magnetic Flux Vector Control (Pr. 71, Pr. 80, Pr. 81, Pr.89, Pr. 800)
81
General-Purpose Magnetic Flux Vector Control (Pr. 71, Pr. 80, Pr. 81, Pr. 800)
84
Slip Compensation (Pr. 245 to Pr. 247)
86
Stall Prevention Operation (Pr. 22, Pr. 23, Pr. 48, Pr. 66, Pr. 156, Pr. 157, Pr. 277)
87
Limit the Output Frequency
91
Maximum/Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)
91
Avoid Mechanical Resonance Points (Frequency Jumps) (Pr. 31 to Pr. 36)
92
Set V/F Pattern
93
Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)
93
Load Pattern Selection (Pr. 14)
95
Frequency Setting by External Terminals
97
Operation by Multi-Speed Operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
97
Jog Operation (Pr. 15, Pr. 16)
99
Remote Setting Function (Pr. 59)
101
Setting of Acceleration/Deceleration Time and Acceleration/ Deceleration Pattern
104
Setting of the Acceleration and Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147)
104
Starting Frequency and Start-Time Hold Function (Pr. 13, Pr. 571)
107
Acceleration/Deceleration Pattern (Pr. 29)
108
Shortest Acceleration/Deceleration (Automatic Acceleration/Deceleration) (Pr. 61 to Pr. 63, Pr. 292, Pr. 293)
109
Selection and Protection of a Motor
111
Motor Overheat Protection (Electronic Thermal O/L Relay) (Pr. 9, Pr. 51)
111
Applied Motor (Pr. 71, Pr. 450)
113
To Exhibit the Best Performance of the Motor Performance (Offline Auto Tuning) (Pr. 71, Pr. 80 to Pr. 84, Pr. 90 to Pr. 94, Pr. 96, Pr. 859)
115
Motor Brake and Stop Operation
123
DC Injection Brake (Pr. 10 to Pr. 12)
123
Selection of a Regenerative Brake (Pr. 30, Pr. 70)
124
Stop Selection (Pr. 250)
126
Stop-On Contact Control Function (Pr. 6, Pr. 48, Pr. 270, Pr. 275, Pr. 276)
127
Brake Sequence Function (Pr. 278 to Pr. 283, Pr. 292)
129
Function Assignment of External Terminal and Control
133
Input Terminal Function Selection (Pr. 178 to Pr. 184)
133
Inverter Output Shutoff Signal (MRS Signal, Pr. 17)
135
Condition Selection of Function Validity by Second Function Selection Signal (RT)
136
Start Signal Operation Selection (STF, STR, STOP Signal, Pr. 250)
137
Output Terminal Function Selection (Pr. 190 to Pr. 192)
139
Detection of Output Frequency (SU, FU Signal, Pr. 41 to Pr. 43)
143
Output Current Detection Function (Y12 Signal, Y13 Signal, Pr. 150 to Pr. 153)
144
Remote Output Selection (REM Signal, Pr. 495 to Pr. 497)
146
Monitor Display and Monitor Output Signal
147
Speed Display and Speed Setting (Pr. 37)
147
Monitor Display Selection of DU/PU and Terminal am (Pr. 52, Pr.158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564)
148
Reference of the Terminal am (Analog Voltage Output) (Pr. 55, Pr. 56)
153
Terminal am Calibration (Calibration Parameter Pr. 645, C1 (Pr.901))
154
Operation Selection at Power Failure and Instantaneous Power Failure
156
Automatic Restart after Instantaneous Power Failure/Flying Start (Pr. 30, Pr. 57, Pr. 58, Pr. 96, Pr. 162, Pr. 165, Pr. 298, Pr. 299, Pr. 611)
156
Power-Failure Deceleration Stop Function (Pr. 261)
162
Operation Setting at Fault Occurrence
164
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
164
Input/Output Phase Loss Protection Selection (Pr. 251, Pr. 872)
166
Earth (Ground) Fault Detection at Start (Pr. 249)
166
Energy Saving Operation
167
Optimum Excitation Control (Pr. 60)
167
Motor Noise, EMI Measures, Mechanical Resonance
168
PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240)
168
Speed Smoothing Control (Pr. 653)
169
Frequency Setting by Analog Input (Terminal 2, 4)
170
Analog Input Selection (Pr. 73, Pr. 267)
170
Response Level of Analog Input and Noise Elimination (Pr. 74)
172
Bias and Gain of Frequency Setting Voltage (Current) (Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905))
173
Misoperation Prevention and Parameter Setting Restriction
178
Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)
178
Parameter Write Disable Selection (Pr. 77)
178
Parameter Write Disable Selection (Pr. 77)
181
Reverse Rotation Prevention Selection (Pr. 78)
182
Extended Parameter Display and User Group Function (Pr. 160, Pr. 172 to Pr. 174)
182
Selection of Operation Mode and Operation Location
185
Operation Mode Selection (Pr. 79)
185
Operation Mode at Power-On (Pr. 79, Pr. 340)
195
Start Command Source and Frequency Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
196
Start Command Source and Frequency Command Source During Communication
196
Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
196
Communication Operation and Setting
202
Wiring and Configuration of PU Connector
202
Initial Settings and Specifications of RS-485 Communication (Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549)
205
Operation Selection at Communication Error Occurrence (Pr. 121, Pr. 122, Pr. 502)
206
Communication EEPROM Write Selection (Pr. 342)
209
Mitsubishi Inverter Protocol (Computer Link Communication)
210
Modbus RTU Communication Specifications (Pr. 117, Pr. 118, Pr. 120, Pr. 122, Pr. 343, Pr. 502, Pr. 549)
222
USB Communication (Pr. 547, Pr. 548)
235
Special Operation and Frequency Control
236
PID Control (Pr. 127 to Pr. 134)
236
Dancer Control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)
243
Droop Control (Pr. 286 to Pr. 287)
249
Regeneration Avoidance Function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)
250
Useful Functions
252
Cooling Fan Operation Selection (Pr. 244)
252
Display of the Life of the Inverter Parts (Pr. 255 to Pr. 259)
253
Maintenance Timer Alarm (Pr. 503, Pr. 504)
257
Current Average Value Monitor Signal (Pr. 555 to Pr. 557)
258
Free Parameter (Pr. 888, Pr. 889)
260
Setting from the Parameter Unit and Operation Panel
261
RUN Key Rotation Direction Selection (Pr. 40)
261
PU Display Language Selection(Pr.145)
261
Operation Panel Frequency Setting/Key Lock Operation Selection (Pr. 161)
262
Magnitude of Frequency Change Setting (Pr. 295)
264
Buzzer Control (Pr. 990)
265
PU Contrast Adjustment (Pr. 991)
265
Parameter Clear/ All Parameter Clear
266
Initial Value Change List
267
Check and Clear of the Faults History
268
Troubleshooting
271
Reset Method of Protective Function
272
List of Fault or Alarm Indications
273
Causes and Corrective Actions
274
Correspondences between Digital and Actual Characters
282
Check First When You Have some Troubles
283
Motor will Not Start
283
Motor Generates Abnormal Noise
283
Motor Generates Heat Abnormally
284
Motor Rotates in Opposite Direction
284
Speed Greatly Differs from the Setting
284
Acceleration/Deceleration Is Not Smooth
284
Motor Current Is Large
284
Speed Does Not Increase
284
Speed Varies During Operation
285
Operation Mode Is Not Changed Properly
285
Operation Panel Display Is Not Operating
285
Parameter Write Cannot be Performed
285
Precautions for Maintenance and Inspection
288
Inspection Items
288
Daily Inspection
288
Periodic Inspection
288
Daily and Periodic Inspection
289
Display of the Life of the Inverter Parts
290
Checking the Inverter and Converter Modules
290
Cleaning
290
Replacement of Parts
291
Inverter Replacement
294
Measurement of Main Circuit Voltages, Currents and Powers
295
Measurement of Powers
297
Measurement of Voltages and Use of PT
297
Measurement of Currents
298
Use of CT and Transducer
298
Measurement of Inverter Input Power Factor
298
Measurement of Converter Output Voltage (Across Terminals P-N)
298
Insulation Resistance Test Using Megger
299
Pressure Test
299
Specifications
301
Rating
302
Inverter Rating
302
Common Specifications
304
Outline Dimension Drawings
305
Appendix
309
Appendix1 for Customers Who Have Replaced the Conventional Model with this Inverter
310
Appendix 1-1 Replacement of the FR-E500 Series
310
Advertisement
Mitsubishi Electric FR-E740-095 Instruction Manual (310 pages)
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 20 MB
Table of Contents
Table of Contents
5
1 Outline
12
Product Checking and Parts Identification
13
Inverter and Peripheral Devices
14
Peripheral Devices
15
Removal and Reinstallation of the Cover
16
Front Cover
16
Wiring
16
Wiring Cover
17
Installation of the Inverter and Enclosure Design
18
Inverter Installation Environment
18
Cooling System Types for Inverter Panel
20
Inverter Placement
21
2 Wiring
24
Terminal Connection Diagram
25
Main Circuit Terminal Specifications
26
Specification of Main Circuit Terminal
26
Terminal Arrangement of the Main Circuit Terminal, Power Supply and the Motor Wiring
26
Cables and Wiring Length
27
Control Circuit Specifications
30
Standard Control Circuit Terminal
30
Connection of Stand-Alone Option Unit
30
Changing the Control Logic
33
Wiring of Control Circuit
35
Wiring Instructions
36
Connection to the PU Connector
37
Connection of Stand-Alone Option Unit
39
Connection of a Dedicated External Brake Resistor (FR-ABR)
39
Connection of the Brake Unit (FR-BU2)
41
Connection of the High Power Factor Converter (FR-HC)
42
Connection of the Power Regeneration Common Converter (FR-CV)
43
Connection of a DC Reactor (FR-HEL)
43
3 Precautions for Use of the Inverter
44
EMC and Leakage Currents
45
Leakage Currents and Countermeasures
45
EMC Measures
47
Power Supply Harmonics
49
Installation of Power Factor Improving Reactor
50
Power-Off and Magnetic Contactor (MC)
51
Inverter-Driven 400V Class Motor
52
Precautions for Use of the Inverter
53
Failsafe of the System Which Uses the Inverter
55
4 Parameters
58
Operation Panel
59
Names and Functions of the Operation Panel
59
Basic Operation (Factory Setting)
60
Easy Operation Mode Setting (Easy Setting Mode)
61
Change the Parameter Setting Value
62
Setting Dial Push
62
Parameter List
63
Control Mode
72
Change the Control Method (Pr. 80, Pr. 81, Pr. 800)
76
Adjust the Output Torque (Current) of the Motor
77
Manual Torque Boost (Pr. 0, Pr. 46)
77
Advance Magnetic Flux Vector Control (Pr. 71, Pr. 80, Pr. 81, Pr.89, Pr. 800)
78
General-Purpose Magnetic Flux Vector Control (Pr. 71, Pr. 80, Pr. 81, Pr. 800)
81
Slip Compensation (Pr. 245 to Pr. 247)
83
Stall Prevention Operation (Pr. 22, Pr. 23, Pr. 48, Pr. 66, Pr. 156, Pr. 157, Pr. 277)
84
Limit the Output Frequency
88
Maximum/Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)
88
Avoid Mechanical Resonance Points (Frequency Jumps) (Pr. 31 to Pr. 36)
89
Set V/F Pattern
90
Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)
90
Load Pattern Selection (Pr. 14)
92
Frequency Setting by External Terminals
94
Operation by Multi-Speed Operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
94
Jog Operation (Pr. 15, Pr. 16)
96
Remote Setting Function (Pr. 59)
98
Setting of Acceleration/Deceleration Time and Acceleration/ Deceleration Pattern
101
Setting of the Acceleration and Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147)
101
Starting Frequency and Start-Time Hold Function (Pr. 13, Pr. 571)
104
Acceleration/Deceleration Pattern (Pr. 29)
105
Shortest Acceleration/Deceleration (Automatic Acceleration/Deceleration) (Pr. 61 to Pr. 63, Pr. 292, Pr. 293)
106
Selection and Protection of a Motor
108
Motor Overheat Protection (Electronic Thermal O/L Relay) (Pr. 9, Pr. 51)
108
Applied Motor (Pr. 71, Pr. 450)
110
To Exhibit the Best Performance of the Motor Performance (Offline Auto Tuning) (Pr. 71, Pr. 80 to Pr. 84, Pr. 90 to Pr. 94, Pr. 96, Pr. 859)
112
Motor Brake and Stop Operation
120
DC Injection Brake (Pr. 10 to Pr. 12)
120
Selection of a Regenerative Brake (Pr. 30, Pr. 70)
121
Stop Selection (Pr. 250)
123
Stop-On Contact Control Function (Pr. 6, Pr. 48, Pr. 270, Pr. 275, Pr. 276)
124
Brake Sequence Function (Pr. 278 to Pr. 283, Pr. 292)
126
Function Assignment of External Terminal and Control
130
Input Terminal Function Selection (Pr. 178 to Pr. 184)
130
Inverter Output Shutoff Signal (MRS Signal, Pr. 17)
132
Condition Selection of Function Validity by Second Function Selection Signal (RT)
133
Start Signal Operation Selection (STF, STR, STOP Signal, Pr. 250)
134
Output Terminal Function Selection (Pr. 190 to Pr. 192)
136
Detection of Output Frequency (SU, FU Signal, Pr. 41 to Pr. 43)
140
Output Current Detection Function (Y12 Signal, Y13 Signal, Pr. 150 to Pr. 153)
141
Remote Output Selection (REM Signal, Pr. 495 to Pr. 497)
143
Monitor Display and Monitor Output Signal
144
Speed Display and Speed Setting (Pr. 37)
144
Monitor Display Selection of DU/PU and Terminal am (Pr. 52, Pr.158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564)
145
Reference of the Terminal am (Analog Voltage Output) (Pr. 55, Pr. 56)
150
Terminal am Calibration (Calibration Parameter Pr. 645, C1 (Pr.901))
151
Operation Selection at Power Failure and Instantaneous Power Failure
153
Automatic Restart after Instantaneous Power Failure/Flying Start (Pr. 30, Pr. 57, Pr. 58, Pr. 96, Pr. 162, Pr. 165, Pr. 298, Pr. 299, Pr. 611)
153
Power-Failure Deceleration Stop Function (Pr. 261)
159
Operation Setting at Fault Occurrence
161
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
161
Input/Output Phase Loss Protection Selection (Pr. 251, Pr. 872)
163
Earth (Ground) Fault Detection at Start (Pr. 249)
163
Energy Saving Operation
164
Optimum Excitation Control (Pr. 60)
164
Motor Noise, EMI Measures, Mechanical Resonance
165
PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240)
165
Speed Smoothing Control (Pr. 653)
166
Frequency Setting by Analog Input (Terminal 2, 4)
167
Analog Input Selection (Pr. 73, Pr. 267)
167
Response Level of Analog Input and Noise Elimination (Pr. 74)
169
Bias and Gain of Frequency Setting Voltage (Current) (Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905))
170
Misoperation Prevention and Parameter Setting Restriction
175
Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)
175
Parameter Write Disable Selection (Pr. 77)
175
Parameter Write Disable Selection (Pr. 77)
178
Reverse Rotation Prevention Selection (Pr. 78)
179
Extended Parameter Display and User Group Function (Pr. 160, Pr. 172 to Pr. 174)
179
Selection of Operation Mode and Operation Location
182
Operation Mode Selection (Pr. 79)
182
Operation Mode at Power-On (Pr. 79, Pr. 340)
192
Start Command Source and Frequency Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
193
Start Command Source and Frequency Command Source During Communication
193
Operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
193
Communication Operation and Setting
199
Wiring and Configuration of PU Connector
199
Initial Settings and Specifications of RS-485 Communication (Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549)
202
Operation Selection at Communication Error Occurrence (Pr. 121, Pr. 122, Pr. 502)
203
Communication EEPROM Write Selection (Pr. 342)
206
Mitsubishi Inverter Protocol (Computer Link Communication)
207
Modbus RTU Communication Specifications (Pr. 117, Pr. 118, Pr. 120, Pr. 122, Pr. 343, Pr. 502, Pr. 549)
219
USB Communication (Pr. 547, Pr. 548)
232
Special Operation and Frequency Control
233
PID Control (Pr. 127 to Pr. 134)
233
Dancer Control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)
240
Droop Control (Pr. 286 to Pr. 287)
246
Regeneration Avoidance Function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)
247
Useful Functions
249
Cooling Fan Operation Selection (Pr. 244)
249
Display of the Life of the Inverter Parts (Pr. 255 to Pr. 259)
250
Maintenance Timer Alarm (Pr. 503, Pr. 504)
254
Current Average Value Monitor Signal (Pr. 555 to Pr. 557)
255
Free Parameter (Pr. 888, Pr. 889)
257
Setting from the Parameter Unit and Operation Panel
258
RUN Key Rotation Direction Selection (Pr. 40)
258
PU Display Language Selection(Pr.145)
258
Operation Panel Frequency Setting/Key Lock Operation Selection (Pr. 161)
259
Magnitude of Frequency Change Setting (Pr. 295)
261
Buzzer Control (Pr. 990)
262
PU Contrast Adjustment (Pr. 991)
262
Parameter Clear/ All Parameter Clear
263
Initial Value Change List
264
Check and Clear of the Faults History
265
5 Troubleshooting
267
Reset Method of Protective Function
268
List of Fault or Alarm Indications
269
Causes and Corrective Actions
270
Correspondences between Digital and Actual Characters
278
Check First When You Have some Troubles
279
Motor will Not Start
279
Motor Generates Abnormal Noise
279
Motor Generates Heat Abnormally
280
Motor Rotates in Opposite Direction
280
Speed Greatly Differs from the Setting
280
Acceleration/Deceleration Is Not Smooth
280
Motor Current Is Large
280
Speed Does Not Increase
280
Speed Varies During Operation
281
Operation Mode Is Not Changed Properly
281
Operation Panel Display Is Not Operating
281
Parameter Write Cannot be Performed
281
6 Precautions for Maintenance and Inspection
284
Inspection Items
284
Daily Inspection
284
Periodic Inspection
284
Daily and Periodic Inspection
285
Display of the Life of the Inverter Parts
286
Checking the Inverter and Converter Modules
286
Cleaning
286
Replacement of Parts
287
Inverter Replacement
290
Measurement of Main Circuit Voltages, Currents and Powers
291
Measurement of Powers
293
Measurement of Voltages and Use of PT
293
Measurement of Currents
294
Use of CT and Transducer
294
Measurement of Inverter Input Power Factor
294
Measurement of Converter Output Voltage (Across Terminals P-N)
294
Insulation Resistance Test Using Megger
295
Pressure Test
295
7 Specifications
297
Rating
298
Inverter Rating
298
Common Specifications
299
Outline Dimension Drawings
300
Appendix
303
Appendix1 for Customers Who Have Replaced the Conventional Model with this Inverter
304
Appendix 1-1 Replacement of the FR-E500 Series
304
Appendix2 Index
306
Mitsubishi Electric FR-E740-095 Installation Manualline (43 pages)
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 3.98 MB
Table of Contents
Table of Contents
1
Product Checking and Parts Identification
4
Outline Dimension Drawings
6
Wiring
8
Precautions for Use of the Inverter
18
Failsafe of the System Which Uses the Inverter
20
Parameter List
21
Troubleshooting
25
Advertisement
Related Products
Mitsubishi Electric FR-E740-095SC
Mitsubishi Electric FR-E740-095-EC
Mitsubishi Electric fr-e740-016
Mitsubishi Electric FR-E740-0.4K(SC)
Mitsubishi Electric FR-E740-0.75K-NE
Mitsubishi Electric FR-E740-040SC
Mitsubishi Electric FR-E740-0.75KNF
Mitsubishi Electric FR-E740-016-EC
Mitsubishi Electric FR-E740-0.75K
Mitsubishi Electric FR-E740-040-EC
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL