2) Remove the fixing [1] (1 screw [2]), and
disconnect the connector [3].
[1]
F-2-34
3) While holding down the front and rear of the
transfer separation charging assembly [1], pull
it toward the front about 1 cm, and then detach
toward the rear left in upward direction.
Clean the transfer separation charging wire
using alcohol.
F-2-35
4) Mount the transfer separation charging
assembly [1] while keeping the following in
mind:
- all solvent must be fully dry.
- the gut wire must not be in contact with the
transfer guide [2] to avoid a cut.
- the grounding plate [3] must be outside the
charging assembly frame.
[2]
[3]
[1]
[2]
[3]
F-2-36
5) Connect the connector of the transfer
separation charging assembly, and fit the fixing
in place.
6) Attach the transfer separation charging
assembly front cover.
7) Fit the fixing transport assembly in place inside
the machine, and shift the fixing transport
assembly lever [1] to lock the assembly in
place.
[1]
F-2-37
8) Remove the primary charging assembly front
cover [1].
- screw [2]
[1]
F-2-38