Chapter 63
Configuring Ethernet OAM and CFM
error-disabled state, or the switch is reloading. It can respond to but not generate Dying Gasp PDUs
based on loss of power. Enter the no ethernet remote-failure {critical-event | dying-gasp | link-fault}
action command to disable the remote failure indication action.

Configuring Ethernet OAM Templates

You can create a template for configuring a common set of options on multiple Ethernet OAM interfaces.
The template can be configured to monitor frame errors, frame-period errors, frame-second errors,
received CRS errors, and symbol-period errors and thresholds. You can also set the template to put the
interface in error-disabled state if any high thresholds are exceeded. These steps are optional and can be
performed in any sequence or repeated to configure different options.
To configure an Ethernet OAM template and to associate it with an interface, follow these steps:
Command
Step 1
Switch# configure terminal
Step 2
Switch(config)# template template-name
Step 3
Switch(config-template)# ethernet oam
link-monitor receive-crc
{
|
high-frames
}
milliseconds
OL-25340-01
{
{
threshold
} |
{
}} |
none
low
low-frames
Purpose
Enters global configuration mode.
Creates a template and enters template configuration mode.
(Optional) Configures thresholds for monitoring ingress
high
frames received with cyclic redundancy code (CRC) errors
window
for a period of time.
Enter threshold high high-frames to set a high
threshold for the number of frames received with CRC
errors. The range is 1 to 65535 frames.
Enter threshold high none to disable the high
threshold.
Enter threshold low low-frames to set a low threshold
in number of frames. The range is 0 to 65535. The
default is 1.
Enter window milliseconds to set the a window and
period of time during which frames with CRC errors
are counted. The range is 10 to 1800 and represents the
number of milliseconds in multiples of 100. The
default is 100.
Software Configuration Guide—Release IOS XE 3.3.0SG and IOS 15.1(1)SG
Enabling and Configuring Ethernet OAM
63-45