hit counter script

Canon imageRUNNER ADVANCE C3325 Series Service Manual page 698

Hide thumbs Also See for imageRUNNER ADVANCE C3325 Series:
Table of Contents

Advertisement

COPIER > OPTION > IMG-FIX
FXS-TMP3
Set ITOP control temp: heavy paper 2
Lv.1 Details
To set the offset of ITOP control temperature for heavy paper 2 (129 to
163 g/m2).
As the value is changed by 1, the control temperature is changed by 5
deg C.
Decrease the value when uneven gloss occurs, and increase the value
when a fixing failure occurs on the leading edge of paper.
Use case
When uneven gloss occurs on the leading edge (74 mm) of heavy
paper 2
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Caution
If the value is too large, uneven gloss may occur.
If the value is too small, a fixing failure may occur on the leading edge
of paper. (Toner does not peel off.)
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
FXS-TMP4
Set ITOP control temp: heavy paper 3
Lv.1 Details
To set the offset of ITOP control temperature for heavy paper 3 (164 to
220 g/m2).
As the value is changed by 1, the control temperature is changed by 5
deg C.
Decrease the value when uneven gloss occurs, and increase the value
when a fixing failure occurs on the leading edge of paper.
Use case
When uneven gloss occurs on the leading edge (74 mm) of heavy
paper 3
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Caution
If the value is too large, uneven gloss may occur.
If the value is too small, a fixing failure may occur on the leading edge
of paper. (Toner does not peel off.)
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
8
Service Mode > COPIER > OPTION > IMG-FIX
8
Service Mode > COPIER > OPTION > IMG-FIX
COPIER > OPTION > IMG-FIX
FXS-TMP5
Set ITOP control temperature: thin paper
Lv.1 Details
To set the offset of ITOP control temperature for thin paper.
As the value is changed by 1, the control temperature is changed by 5
deg C.
Decrease the value when uneven gloss occurs, and increase the value
when a fixing failure occurs on the leading edge of paper.
Use case
When uneven gloss occurs on the leading edge (74 mm) of thin paper
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Caution
If the value is too large, uneven gloss may occur.
If the value is too small, a fixing failure may occur on the leading edge
of paper. (Toner does not peel off.)
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
FXS-TMP6
Set ITOP control temperature: envelope
Lv.1 Details
To set the offset of ITOP control temperature for envelope.
As the value is changed by 1, the control temperature is changed by 5
deg C.
Decrease the value when uneven gloss occurs, and increase the value
when a fixing failure occurs on the leading edge of paper.
Use case
When uneven gloss occurs on the leading edge (74 mm) of envelope
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Caution
If the value is too large, uneven gloss may occur.
If the value is too small, a fixing failure may occur on the leading edge
of paper. (Toner does not peel off.)
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
8-147
8-147

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF