Page 6
Note that the basic information, such as the operation procedures of the device and OS, is omitted. NEC Corporation 2011-2014 No part of this guide may be reproduced or changed in any form without prior written permission of NEC Corporation. Regulatory Notices...
Page 7
Disposing of your used product In the European Union EU-wide legislation as implemented in each Member State requires that used electrical and electronic products carrying the mark (left) must be disposed of separately from normal household waste. When disposing of used products, you should comply with applicable legislation or agreements you may have.
Page 10
Table Of Contents Table of Contents Precautions for Use ..................... vii Safety Indications ........................vii Symbols Used in This User’s Guide ................viii 安全注意事項 ..........................x Precautions for Safety......................xiii Introduction ......................44 About this guide ....................44 Text Conventions ........................44 Repurchasing This Guide ....................
Precautions for Use Keep this User’s Guide at hand for quick reference at anytime necessary. Be sure to read this section carefully. Precautions for Use -Be sure to read this section - The following includes information necessary for proper and safe operation of the product. See the "Product Overview"...
Precautions for Use Term indicating a degree of danger Description of a danger Symbol to draw attention WARNING Do not plug the power cord in a nonconforming outlet Use a wall outlet with specified voltage and power type. Otherwise, there is a risk of a fire or current leakage. Symbols Used in This User’s Guide Attentions Indicates that improper use may cause an...
Page 19
Precautions for Use Safety Instructions Rack Mount CAUTION Elevated Operating Ambient If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
NEC assumes no liability for any accident resulting in personal injury, death, or property damage if the product has been used in the above conditions.
Page 24
Do not use any unauthorized interface cable. Use only interface cables authorized by NEC and locate a proper device and connector before connecting a cable. Using an authorized cable or connecting a cable to an improper destination may cause a short circuit, resulting in a fire.
Page 25
Precautions for Use Precautions for Cleaning and Handling of Internal Devices WARNING Do not disassemble, repair, or modify the product yourself Do not disassemble, repair, or modify this product. Doing so may cause an electric shock or a fire. Do not put the product close to fire, or immerse it in water. Doing so may cause an explosion.
Page 26
Precautions for Use Anti-Static Measures Installing or Uninstalling an Internal Optional Device 1. Notes before carrying out the work (1) To avoid electric hazard and malfunction, be sure to turn off the Power switch of this product and unplug the power cord from an outlet before carrying out the work. However, there is no need to do this if the internal optional device is hot-swappable.
Page 35
(Japanese) 各 portmode と本スイッチ上のポート番号の対応は以下となります。 portm ode m ode1 m ode2 mode3 m ode4 Port No. Port No. Port N o. Port No. CPU ブレー ド Slot #1 CPU ブレー ド Slot #2 CPU ブレー ド Slot #3 CPU ブレー ド Slot #4 CPU ブレー...
Page 36
(Japanese) 【N8406-051 10GbE インテリジェントスイッチ(L3)の内部/外部ポートの構成図】 内部インタフェース 内部インタフェース 収納ユニット内部 収納ユニット内部 隣接スロットへ 隣接スロットへ EMカードへ EMカードへ CPU ブレードへ CPU ブレードへ 管理用LANへ 管理用LANへ インターリンクポート インターリンクポート マネジメントポート マネジメントポート (Interlinkport) (Interlinkport) CPUブレードポート CPUブレードポート 10/100Mbps 10/100Mbps 10Gbps 10Gbps 固定 固定 1 /10Gbps 1 /10Gbps port port port port port port port...
(English) Introduction Thank you very much for purchasing our 10Gb Intelligent L3 Switch. To maximize the functionality of this product, please read this guide carefully and follow the instructions for proper handling. About this guide This guide describes how to handle and use this product properly. Keep this guide at hand for your future reference.
(English) Additional references Detailed information about how to configure this product is described in the reference guides listed below. These guides are contained in the attached CD-ROM. ・ 10Gb Intelligent L3 Switch Application Guide ・ 10Gb Intelligent L3 Switch Command Reference Guide (BLADE OS) 10Gb Intelligent L3 Switch Command Reference Guide (ISCLI) ・...
Page 57
(English) Description ■ N8406-051F N8406-051F N8406-051F -38- -38- -39- -39- -40- -40- -41- -41- -42- -42- -43- -43- -44- -44- -45- -45- 50-53 50-53 46-49 46-49 Name Description 1. ID LED The LED is intended to identify the Switch Module in the Blade Enclosure. The LED is lit by software command.
Page 58
(English) ■ N8406-052F N8406-051F N8406-052F -38- -38- -39- -39- -40- -40- -41- -41- -42- -42- -43- -43- -44- -44- -45- -45- 50-53 50-53 46-49 46-49 Name Description 1. ID LED The LED is intended to identify the Switch Module in the Blade Enclosure. The LED is lit by software command.
Modules are installed. Making this LED being lit can help the maintenance work to identify the faulty device. When the recognized command is received from the management software such as NEC ESMPRO/Server Manager, the LED goes on or flashes in blue.
(English) Number of ports ■ N8406-051F The following table lists the ports. Category Port number Speed Description Internal interface CPU Blade 1-16 1/10Gbps The ports dedicated to the CPU Blade. Each port connects with each CPU Blade installed the Blade Slot in the Blade Enclosure. The connection is difference between the Blade Enclosures and depends on the port mode configuration.
Page 61
(English) The Switch Module has four portmodes. The following table lists the ports of each portmode. portmode CPU Blade Adjacent switch module Uplink 1-16 portmode 1 Not available 38-45 (1port x 16 CPU Blades) 1-16 portmode 2 33-36 38-41 (1port x 16 CPU Blades) 1-16 portmode 3 Not available...
Page 62
(English) Correspondence of the port number on each portmode and this switch is the following: portmode mode1 mode2 mode3 mode4 Port No. Port No. Port No. Port No. CPU Blade Slot #1 CPU Blade Slot #2 CPU Blade Slot #3 CPU Blade Slot #4 CPU Blade...
Page 63
(English) N8406-051F 10Gb Intelligent L3 Switch internal and external ports connection diagram Internal interface Internal interface To CPU Blade To CPU Blade Connected to Connected to To adjacent To adjacent management network management network Switch Module slot Switch Module slot In Blade Enclosure In Blade Enclosure 1/10G...
Page 64
(English) ■ N8406-052F The following table lists the ports. Category Port number Speed Description Internal interface CPU Blade 1-32 1/10Gbps The ports dedicated to the CPU Blade. Two each ports connect with each CPU Blade installed the Blade Slot in the Blade Enclosure. Switch Module 33-36 10Gbps...
Page 65
(English) You need to select QSFP portmodes. The following table lists the available modules and cables on each portmode. QSFP portmode Available modules and cables N8406-053F 40GBASE-SR QSFP+ Module Port 46 – 40G Mode K410-235(03) 3m 40G QSFP+ Copper Cable Port 46, 47, 48, 49 –...
Page 66
(English) N8406-052F 10Gb Intelligent L3 Switch internal and external ports connection diagram Internal interface Internal interface To CPU Blade To CPU Blade Connected to Connected to To adjacent To adjacent management network management network Switch Module slot Switch Module slot In Blade Enclosure In Blade Enclosure 1/10G...
(English) Network Cables Your network cables must have the following specifications: N8406-037F 10GBase-SR SFP+ module Connector LC connector Multimode Fiber (MMF) cable Type of Cable Core size: 50um Cable Length OM3 class 300m max (when the core size is 50μm) (max.) N8406-053F 40GBase-SR QSFP+ module Connector...
(English) Installation Installing Switch Module Refer to the Blade Enclosure User’s Guide for details. Open the ejector of 10Gb Intelligent L3 Switch. Ejector With the ejector being opened, insert the Switch Module into the Blade Enclosure. Bla de E nc lo s ure Eje c to r Close the ejector to fix the Switch Module to the Blade Enclosure.
(English) IMPORTANT: The Switch Module works with the Blade Enclosure. The Switch ・ Module is powered on as soon as it is installed in the powered Blade Enclosure. Therefore, make sure that the ports connected with the Switch Module are only the ports of on-board LAN and NIC on the CPU Blade.
Page 70
(English) With the ejector being open, firmly hold the Switch Module and slowly pull out from the Blade Enclosure. IMPORTANT: Install the Switch Module in the Blade Enclosure after the period of 30 ・ seconds or longer has passed from removing it from the powered Blade Enclosure.
Page 71
(English) Installing and Removing SFP+ Module The following is described how to install and remove the Option SFP+ Module in and from the Switch Module. IMPORTANT: Attach the dust covers to all vacant LC connectors to protect them ・ from contamination, if you store or transport the Switch Module which the SFP+ modules are installed.
Page 72
(English) Removing SFP+ Module Remove the optical fiber cable, and pull down the SFP+ module lever. Switch Module SFP+ module Pull down the lever Hold the lever and pull the SFP+ module straight. Switch Module IMPORTANT: Contact your service representative for placing optical fiber cables. ・...
(English) Configuration The Switch Module can be configured locally using the Serial Port or remotely using the Ethernet ports. Connection via Serial Port Serial interface is connected between this switch module and the EM card. Therefore It is available to connect from the Enclosure Manager by using "CONNECT SWITCH"...
Page 74
(English) ISCLI Switch> enable (Enter Privileged EXEC mode) Switch# configure terminal (Enter Global Configuration mode) Switch(config)# no system dhcp (Disable dhcp) Switch(config)# interface ip 256 (Enter Interface IP Configuration mode) Switch(config-ip-if)# ip address 205.21.17.3 255.255.255.0 (Assign IP address for the Interface) Switch(config-ip-if)# enable (Enable IP interface 256) Switch(config-ip-if)# exit...
Page 75
(English) User access levels The Switch Module provides three levels for user access. The default user names/passwords for each access level is listed in the following table. User account Description Password (Default) user The user can view all the Switch Module status information and statistics, user but cannot make any configuration changes to the Switch Module.
(English) Troubleshooting This section describes the action to be taken at an occurrence of trouble. If the Switch Module still fails to operate, contact your service representative. Fails to insert or remove the Switch Module. Make sure that there is no foreign object inside the Switch Module slot. Make sure that you have installed the Switch Module in the right direction.
Page 77
(English) Network adapter Teaming feature of the CPU Blade does not work. Once the teaming adapter is removed, make sure that each interface is available.. Make sure that the teaming is correctly configured and the network is correctly deployed, if it is not available only by using the teaming feature.