hit counter script
Download Print this page
Sealey SA660 Manual

Sealey SA660 Manual

Air needle scaler composite pistol type

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAfETY
WARNING! ensure health & safety, local authority, and general workshop practice regulations are adhered to when using this
equipment.
WARNING! disconnect from air supply before changing accessories or servicing.
Maintain the needle scaler in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may
be dangerous and will invalidate the warranty.
WARNING! Check correct air pressure is maintained and not exceeded. We recommend 90psi.
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use and ensure that all connections are
9
secure.
Only use needles which are specifically designed for use with a needle scaler.
9
Wear approved safety eye/face shield, ear defenders, and hand protection.
9
Maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and non essential persons away from the working area.
9
DO NOT use the needle scaler for a task it is not designed to perform.
8
WARNING! DO NOT use needle scaler if damaged or thought to be faulty. (Contact Sealey service agent).
DO NOT use needle scaler unless you have been instructed in its use by a qualified person.
8
DO NOT carry the needle scaler by the air hose, or yank the hose from the air supply.
8
DO NOT operate needle scaler if you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT carry needle scaler with your hand on the power trigger in order to avoid unintentional starting.
8
DO NOT direct air from the air hose at yourself or others.
8
When not in use disconnect from air supply and store in a safe, dry, childproof location.
9
2. INTRODuCTION
Suitable for cleaning heavy paint and rust scale from metal surfaces. Composite housing protects user from chill and helps to reduce
vibration. Soft-grip handle and in-line handle provide added comfort and control. Spare needle sets are readily available.
3. SPECIfICATION
Stroke: ......................................................................... 38mm
Free Speed: ............................................................ 4500bpm
Air Consumption:.......................................................... 12cfm
operating Pressure: ...................................................... 90psi
Air Inlet Size: .............................................................1/4"BSP
Weight: .......................................................................... 1.7kg
noise Power: ..........................................................107.1dB.A
noise Pressure: .......................................................97.1dB.A
Vibration: .................................................................... 6.3m/s²
Uncertainty: .............................................................. 3.15m/s²
4. PREPARATION
© Jack Sealey limited
AIR NEEDLE SCALER COMPOSITE PISTOL TYPE
Model no:
Wear protective
Wear safety
gloves
footwear
Original Language Version
SA660
Wear ear
protection
fig.1
SA660 Issue 3 (HF) 13/06/18

Advertisement

loading

Summary of Contents for Sealey SA660

  • Page 1 SA660 Model no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Vibration may cause failure if a quick change coupling is connected directly to the needle scaler. To overcome this, connect a leader hose to the needle scaler (Sealey ref: AH2R or AH2R/38). A quick change coupling may then be used to connect the leader hose to the air line recoil hose.