hit counter script

Cable Guide - Cisco NCS 1001 Hardware Installation Manual

Hide thumbs Also See for NCS 1001:
Table of Contents

Advertisement

Cable Guide

Procedure
Step 1
Verify that the office ground cable is connected to the top of the rack and the office ground, according to local
site practice.
Step 2
Remove any paint and other nonconductive coatings from the surfaces between the shelf ground and bay
frame ground point. Clean the mating surfaces and apply appropriate antioxidant compound to the bare
conductors.
Step 3
Attach one end of the shelf ground cable (#8 AWG cable) to the ground point using the specified dual-hole
lug connector. See
Figure 32: NCS 1001 Ground Lug
The orientation of the lug cable is always at the bottom side.
1
2
3
Step 4
Tighten the M4 pan-head screw to torque value of 1.3 N-m (11.5 in-lbs).
Step 5
Attach the other end of the shelf ground cable to the bay frame using a dual-hole lug connector according to
the equipment rack frame specifications.
Cable Guide
The attachment of the cable guide is as shown below.
Hardware Installation Guide for Cisco NCS 1001
34
Figure 18: Grounding Extender, on page
Ground lug
Star washer (part number - 48-1354-01)
Screws for lug (part number - 48-2835-01)
Install Cisco NCS 1001
21.