Replace Hvac And Hvdc Power Module - Cisco Nexus 9808 NX-OS Hardware Installation Manual

Mode switch
Table of Contents

Advertisement

Replace HVAC and HVDC Power Module

c) Repeat Step 1 through Step 3 for the other power trays.
Caution
Caution
Step 4
Replace the clear plastic safety covers over the DC power connection terminal studs and tighten the screws.
Step 5
Set the DC power source circuit breaker to ON (1).
Step 6
Set the power tray switch to ON (1).
Caution
Replace HVAC and HVDC Power Module
Follow these steps to remove HVAC and HVDC power modules from the chassis.
Procedure
Step 1
Do not Power OFF (0) the standby mode switch.
Cisco Nexus 9808 NX-OS Mode Switch Hardware Installation Guide
98
To prevent injury and damage to the equipment, always attach the ground and source DC
power cable lugs to the power tray terminals in the following order: (1) positive (+) to positive
(+), (2) negative (–) to negative (–).
Do not overtighten the nuts that secure the DC power cables to the power tray terminals. The
nuts should be tightened using the 7/16 hex socket and torque wrench to a torque of 45–50
in-lb.
Use this procedure only when reconnecting power to all power modules in a system that is powered
down completely.