Status and Statistics
RMON
To clear statistics counters:
•
Click Clear Interface Counters to clear the selected interfaces counters.
•
Click View All Interfaces Statistics to see all ports on a single page.
RMON History
The RMON feature enables monitoring statistics per interface.
The History Control Table page defines the sampling frequency, amount of samples to store and the port
from which to gather the data.
After the data is sampled and stored, it appears in the History Table page that can be viewed by clicking
History Table.
To enter RMON control information:
STEP 1
•
Current Number of Samples—RMON is allowed by the standard to not grant all requested samples,
but rather to limit the number of samples per request. Therefore, this field represents the sample
number actually granted to the request that is equal or less than the requested value.
STEP 2
STEP 3
•
New History Entry—Displays the number of the new History table entry.
•
Source Interface—Select the type of interface from which the history samples are to be taken.
•
Max No. of Samples to Keep—Enter the number of samples to store.
•
Sampling Interval—Enter the time in seconds that samples are collected from the ports. The field
range is 1-3600.
•
Owner—Enter the RMON station or user that requested the RMON information.
STEP 4
STEP 5
Cisco Small Business 200 Series Smart Switch Administration Guide
Click Status and Statistics > RMON > History. The fields displayed on this page
are defined in the Add RMON History page, below. The only field is that is on this
page and not defined in the Add page is:
Click Add.
Enter the parameters.
Click Apply. The entry is added to the History Control Table page
Configuration file is updated.
Click History Table (described below) to view the actual statistics.
3
,
and the Running
24