Chapter 2
- If the detected temperature of the thermistor does not reach 70 deg C within a specified
period after it once reaches 40 deg C after the heater energization during the wait period.
- If the detected temperature of the thermistor does not reach the targeted temperature within a specified period under the heater temperature control during the
initial rotation period.
2) Abnormal low temperature
- If the detected temperature of the thermistor is kept 100 deg C or lower for a specified period under the heater temperature control during the print period.
3) Abnormal high temperature
- If the detected temperature of the thermistor is kept 230 deg C or higher for a specified period.
4) Fixing heater drive circuit failure
- If the specified count of the ZERO CROSSING signal is not detected within a specified period after the printer is turned on.
- If the ZERO CROSSING signal is not detected for a specified period during the print period after the signal is once detected after the printer is turned on.
2.7 EXTERNAL AND CONTROLS SYSTEM
2.7.1 Power Supply
2.7.1.1 Power Supply
2.7.1.1.1 Low-voltage power supply
The low-voltage power supply and the fixing power supply convert AC power from the power receptacle into DC power to cover the DC loads.
- Low-voltage power supply:
Generates DC power required in the printer
- Fixing power supply:
Supplies AC power to the low-voltage power supply
Controls the fixing heater temperature in the fixing unit
AC input
Fuse
FU2801
Noise filter
Rectifyin g
circuit
For low pressure power, insert the AC power in the inlet, switch the power ON, and it will start. The AC power generates +3.3V in the fixing power, +24V in the
2-16
Fuse
FU2901
Noise filter
Protection circui t
+3.3V generation
circuit
+24V generation
circuit
Fixing power suppl y
Fixing control
circuit
Zero crossing
circuit
Power switch
control circui t
Power switc h
SW3001
Low-voltage power suppl y
Power supply uni t
F-2-20
ZEROX
+3.3V
DC controller
PSREM24V
+24V
0021-2056