Checking before Installation
Following shows requirements for the installation site.
Therefore, it is desirable to see the installation site in advance before bringing in the machine
to the user's site.
Checking Power Supply
1) There must be a properly grounded source of power that can be used exclusively by the
following machines:
EUR: 200V/10A
USA: 120V/16A
Checking the Installation Environment
1) The environment of the installation site must be in the range as shown below. Avoid
installation near the faucet, water boiler, humidifier or refrigerator.
Guaranteed range for operation/image Temperature: 10.0 to 30.0 deg C, Humidity: 20 to
80%
2) The machine must not be installed near a source of fire or in an area subject to dust or
ammonium gas. If the area is exposed to direct rays of the sun, provide curtains to the
window.
3) Be sure to provide adequate ventilation of the room to keep the work environment
comfortable. Room odor can be bothering when running the machine for a long time in a
poorly-ventilated room although the ozone amount generated while running this equipment
does not harm human health.
9
Installation > Checking before Installation > Checking Installation Space
Checking Installation Space
1) The foot of this equipment should be in contact with the floor. This equipment should be
kept on the level.
2) The machine must be away from the wall by 100mm or more to secure a sufficient space to
operate the machine.
• The optional Booklet Finisher, External 2/3 Hole Puncher, Document Insertion/Folding
Unit, Duplex Color Image Reader Unit, Upright Control Panel, and Paper Deck Unit-D1 are
attached.
9
Installation > Checking before Installation > Checking Installation Space
500 mm
2,608 mm
or more
9-2
800 mm or more
500 mm
500 mm
or more
or more
F-9-1
9-2