COPIER > FUNCTION > PART-CHK
MTR-ON
Operation check of Motor
Lv.1 Details
To start operation check of the Motor specified by MTR.
The operation automatically stops after operation of 20 seconds.
Use case
When replacing the Motor/checking the operation
Adj/set/operate method Select the item, and then press OK key.
Caution
Be sure to remove the Toner Container before Toner Supply Motor
(M10) is activated. If it remains to be installed, toner is supplied.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Required time
1 minute
Related service mode
COPIER> FUNCTION> PART-CHK> MTR
SL
Specification of operation Solenoid
Lv.1 Details
To specify the Solenoid to operate.
Use case
When replacing the Solenoid/checking the operation
Adj/set/operate method Enter the value, and then press OK key.
Display/adj/set range
1 to 10
1: Multi Middle Plate Release Solenoid (SL2)
2: Cassette 3 Pickup Solenoid (SL3)
3: Cassette 4 Pickup Solenoid (SL4)
4: Reverse Upper Flapper Solenoid (SL5)
5: Right Deck Pickup Solenoid (SL6)
6: Not used
7: Left Deck Merging Solenoid (SL11)
8: Fixing Cleaning Web Drive Solenoid (SL9)
9 to 10: Not used
Default value
1
Related service mode
COPIER> FUNCTION> PART-CHK> SL-ON
SL-ON
Operation check of Solenoid
Lv.1 Details
To start operation check for the Solenoid specified by SL.
The operation stops after "ON for 0.5 sec" => "OFF for 10 sec" => "ON
for 0.5 sec" => "OFF for 10 sec" => "ON for 0.5 sec".
Use case
When replacing the Solenoid/checking the operation
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Required time
1 minute
Related service mode
COPIER> FUNCTION> PART-CHK> SL
8
Service Mode > COPIER > FUNCTION > CLEAR
T-8-47
8
Service Mode > COPIER > FUNCTION > CLEAR
■ CLEAR
COPIER > FUNCTION > CLEAR
ERR
Clear of error code
Lv.1 Details
To clear error codes (E000, E001, E002, E003, E717, E719).
E000, E001, E002, and E003 are fixing-related errors.
E004 (IH Power Supply) and E005 (Web absence) do not need to be
cleared.
Use case
At error occurrence
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
DC-CON
RAM clear of DC Controller PCB
Lv.1 Details
To clear the RAM data of the DC Controller PCB.
Use case
When clearing the RAM data of the DC Controller PCB
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Output the service mode setting values by P-PRINT before
execution. After execution, enter necessary setting values.
- The RAM data is cleared after the main power switch is turned
OFF/ON.
Related service mode
COPIER> FUNCTION> MISC-P> P-PRINT
R-CON
RAM clear of Reader Controller PCB
Lv.1 Details
To clear the RAM data of the Reader Controller PCB.
Use case
When clearing the RAM data of the Reader Controller PCB
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Output the service mode setting values by P-PRINT before
execution. After execution, enter necessary setting values.
- The RAM data is cleared after the main power switch is turned
OFF/ON.
Related service mode
COPIER> FUNCTION> MISC-P> P-PRINT
JAM-HIST
Clear of jam history
Lv.1 Details
To clear the jam history.
Use case
When clearing the jam history
Adj/set/operate method Select the item, and then press OK key.
ERR-HIST
Clear of error code history
Lv.1 Details
To clear the error code history.
Use case
When clearing the error code history
Adj/set/operate method Select the item, and then press OK key.
PWD-CLR
Clear of system administrator password
Lv.1 Details
To clear the password of the system administrator set in the user
mode.
Use case
When clearing the password of the system administrator
Adj/set/operate method Select the item, and then press OK key.
8-105
8-105