V-Cont - Canon imageRUNNER ADVANCE 6075 Series Service Manual

Table of Contents

Advertisement

■ V-CONT

COPIER > ADJUST > V-CONT
EPOTOFST
Manual entry of Potential Sensor offset
Lv.1 Details
To set the offset auto adjustment value of Potential Sensor manually.
As the value is incremented by 1, the offset value changes by 1V.
+: Identified as the lower potential than the detected one
-: Identified as the higher potential than the detected one
Use case
When an error is displayed by executing OFST (auto offset
adjustment) at the replacement of Potential Sensor (When the value
out of specified range is set due to Potential Sensor disconnection/
connection failure/installation failure), restore to the factory setting
values.
1) To stop the error, set 0 (V) in EPOTOFST.
2) Check around the Potential Sensor.
If there is an error, address it and if not, go to the step 3).
3) Enter the value of service label.
4) If image fogging or the like occurs, increase the value by 10V
increment.
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this at the normal service.
Display/adj/set range
0 to 255
Unit
1 V
Default value
0
Related service mode
COPIER> FUNCTION> DPC> OFST
VL-OFST
Bright area tgt potential ofst VL entry
Lv.1 Details
To set the offset auto adjustment value of bright area target potential
VL manually.
As the value is incremented by 1, the offset value changes by 1V.
+: Increase
-: Decrease
Use case
When replacing the DC Controller PCB/clearing RAM data
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this at the normal service.
Display/adj/set range
-30 to 30
Unit
1 V
Default value
0
8
Service Mode > COPIER > ADJUST > V-CONT
8
Service Mode > COPIER > ADJUST > V-CONT
COPIER > ADJUST > V-CONT
VD-OFST
Dark area tgt potential ofst VL entry
Lv.1 Details
To set the offset auto adjustment value of dark area target potential
VL manually.
As the value is incremented by 1, the offset value changes by 1V.
+: Increase
-: Decrease
Use case
When replacing the DC Controller PCB/clearing RAM data
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this at the normal service.
Display/adj/set range
-30 to 30
Unit
1 V
Default value
0
DE-OFST
Copy image Vdc offset value entry
Lv.1 Details
To set the Vdc offset auto adjustment value for potential control of
copy image manually.
As the value is incremented by 1, the offset value changes by 1V.
+: Increase
-: Decrease
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-50 to 50
Unit
1 V
Default value
0
VCONT-1
Dev contrast crrct potntl:first time/day
Lv.1 Details
To make a fine adjustment of correction potential of developing
contrast target potential Vcont for the first time of the day.
Use case
When image density for the first time of the day is low
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 10
Unit
1 V
Default value
0
VL-OF-L
Bright area target potential:thin
Lv.2 Details
To make a fine adjustment of bright area target potential VL with thin
paper.
Use case
When an image density failure occurs with thin paper
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-200 to 200
Unit
1 V
Default value
20
VL-OF-H1
[Not used]
Lv.2 Details
-
VL-OF-H2
[Not used]
Lv.2 Details
-
8-80
T-8-32
8-80