To specify an event criteria for an Embedded Event Manager (EEM) applet that is run on the basis of a
temperature event, use the event temperature command. To remove the temperature event criteria, use
the no form of this command.
Syntax Description
module module
sensor number
threshold
any
major
minor
Defaults
None
Command Modes
Embedded event manager configuration mode
Command History
Release
5.0(3)U3(1)
Usage Guidelines
This command does not require a license.
Examples
This example shows how to specify that an EEM applet runs when a temperature event occurs:
switch# configure terminal
switch(config)# event manager applet temp-applet
switch(config-applet)# event temperature threshold major
switch(config-applet)#
Cisco Nexus 3000 Series NX-OS System Management Command Reference
-SM-74
event temperature [module module] [sensor number] threshold {any | major | minor}
no event temperature [module module] [sensor number] threshold {any | major | minor}
(Optional) Specifies that a specific module must be monitored. The range is from
1 to 1.
(Optional) Specify that a specific sensor must be monitored. The range is from 1
to 8.
Specifies the threshold event that triggers the EEM applet. Choose either major,
minor, or any.
Specifies any event.
Specifies a major event.
Specifies a minor event.
Modification
This command was introduced.