9-5. AUTO CHANGE OVER ∙∙∙ AUTO MODE OPERATION
Once desired temperature is set, unit operation is switched automatically between COOL and HEAT operation.
Mode selection
(1) Initial mode
When unit starts the operation with AUTO operation from OFF:
• If the room temperature is higher than the set temperature, operation starts in COOL mode.
• If the room temperature is equal to or lower than the set temperature, operation starts in HEAT mode.
(2) Mode change
COOL mode changes to HEAT mode when about 15 minutes have passed with the room temperature 1°C below the
set temperature.
HEAT mode changes to COOL mode when about 15 minutes have passed with the room temperature 1°C above the
set temperature.
NOTE 1
If 2 or more indoor units are operating in multi system, there might be a case that the indoor unit, which is operating in
(AUTO), cannot change over to the other operating mode (COOL ↔ HEAT) and becomes a state of standby.
Refer to NOTE 2 "FOR MULTI SYSTEM AIR CONDITIONER".
NOTE 2
FOR MULTI SYSTEM AIR CONDITIONER
OUTDOOR UNIT: MXZ series
Multi system air conditioner can connect 2 or more indoor units with one outdoor unit.
• When you try to operate 2 or more indoor units with one outdoor unit simultaneously, one for the cooling and the oth-
ers for heating, the operation mode of the indoor unit that operates first is selected. Other indoor units cannot operate,
and operation indicator lamp blinks as shown in the figure below. In this case, please set all the indoor units to the
same operation mode.
• When indoor unit starts the operation while the defrosting of outdoor unit is being done, it takes a few minutes (max. 10
minutes) to blow out the warm air.
• In the heating operation, though indoor unit that does not operate may get warm or the sound of refrigerant flowing
may be heard, they are not malfunction. The reason is that the refrigerant continuously flows into it.
OPERATION INDICATOR
21
Lit
Blinking
Not lit