Thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. safeTy
warning! ensure all Health and Safety, local authority and general workshop practice regulations are strictly adhered to when using
this equipment.
Familiarise yourself with the applications, limitations and potential hazards of this product.
9
Maintain the pump in good condition (use an authorised service agent).
9
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts will invalidate the warranty.
9
Use only with oils, anti-freeze, degreasers and other non-corrosive fluids.
9
ensure safety eye protection and protective clothing are worn when using this product.
9
Keep the work area clean and uncluttered and ensure that there is adequate lighting.
9
Maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and unauthorised persons away from the work area.
9
dispose of waste liquids in accordance with local authority regulations.
9
Do noT use the pump to transfer hazardous or harmful chemicals, solvents, petrol or acids.
8
Do noT use the pump with water.
8
Do noT use the pump for any purpose other than for which it is designed.
8
Do noT attempt to move the fluid drum by pulling on the pump.
8
Keep the pump clean and well oiled and store in a safe, dry location when not in use.
9
2. inTroDuCTion
Manufactured from hard wearing and durable polyethylene. 55ltr Capacity suitable for the distribution of diesel, oil, AdBlue®, Water and
Antifreeze. Model No. DT55RCOMBO1 (Red) is supplied with Model No. TP55 Oil Rotary Pump, fitted with two roller wheels, hose holder and
vent caps. Features a 2"BSP thread and four point screw fittings enabling other pumps to be fitted as required.
3. asseMbly
3.1.
The bottom of the suction tube is designed to sit on the bottom of the tank without
obstructing the flow into the tube.
3.2.
Pass drum adaptor over the threaded end of the suction tube. Slacken the drum adaptor
by twisting the top ring (fig.2) until it slides freely on the tube. Screw into the top of the
drum (fig.4) and tighten the top ring (fig.3).
3.3.
Attach the bracket the top set of nuts moulded into the plastic. Do noT fully tighten the
screws just yet (fig.4).
3.4.
Attach the other half of the bracket capturing the suction tube (fig.6), tighten the screws.
3.5.
Screw the pump body onto the suction tube, it is advised that you hold the tube while
screwing the pump onto it.
3.6.
Attach the handle and secure it by screwing the bolt onto the flat (fig.5).
© Jack Sealey limited
Mobile Dispensing Tank 55lTr wiTh oil
roTary puMp - reD
Model no:
Wear protective
gloves
fig.1
Original Language Version
DT55rCoMbo1
fig.4
fig.3
dT55RCoMBo1 Issue 1 21/12/18
fig.2