Page 1
N8800-124F, EXP320J NEC Express5800/320Fd-LR N8800-125F, EXP320K NEC Express5800/320Fd-MR User's Guide (Setup) 2nd Edition 10-2008 856-127506-122-B...
Page 2
The NEC product(s) discussed in this document are warranted in accordance with the terms of the Warranty Statement accompanying each product. However, actual performance of each such product is dependent upon factors such as system configuration, customer data, and operator control.
Page 3
Keep this User's Guide handy for quick reference when necessary. Safety Indications To use NEC Express5800 series safely, follow the instructions in this User's Guide. This guide explains components that pose a danger, types of dangers caused by failing to follow the instructions, and actions taken to prevent them;...
Page 4
Symbols and its descriptions used in this User’s Guide and warning labels are as follows: Attention Indicates a risk of an electric shock. Indicates a risk of a personal injury due to heat. Indicates a risk of catching your fingers. Indicates a risk of a fire or smoke.
Page 5
Mandatory actions Unplug the server. There is a risk of an electric shock or fire. Indicates a general action to take that is not defined herein. Make sure to follow the instructions. For detailed notes to set up the machine safely, refer to “NOTES FOR SAFE HANDLING” on page 1-2.
Page 9
Trademarks and Patents NEC EXPRESSBUILDER, NEC ESMPRO and DianaScope are registered trademarks of NEC Corporation. Microsoft, Windows, Windows Server, Windows NT, and MS-DOS are registered trademarks of Microsoft Corporation in the United States and other countries. Intel and Pentium are registered trademarks of Intel Corporation.
Page 10
(5) NEC assumes no liability arising from the use of this product, nor any liability for incidental or consequential damage arising from the use of this manual regardless of (4) above.
“high performance,” “scalability,” and “general versatility” provided by NEC Express5800 series. In the event of trouble, its dual configuration will allow the system to isolate instantaneously the failed parts to assure non-stop running; operation will be moved smoothly from one module to the other, minimizing damage to it.
Something you need to make sure when using the server or software Helpful information, something useful to know TIPS: About our Web Service Information on NEC Express5800/ft series including modification modules is also available on our web site, NEC Express5800 Web Site Asia Pacific: http://www.nec.co.jp/express/index.html...
CHAPTER 3 INSTALLING SERVER ................3-1 INSTALLATION .........................3-2 Rack-mount Model ......................3-2 Installing the Tower Conversion Kit (N8843-002)............3-13 CONNECT PERIPHERAL DEVICES TO NEC EXPRESS5800/FT SERIES ....3-18 CHAPTER 4 LINUX SETUP....................4-1 BEFORE STARTING SETUP ....................4-2 SETUP FLOW ........................4-3 Step 1: Things Required for Setup .................4-4 Step 2: Prepare for Express Setup .................4-5...
Page 16
Step 5: Post OS Install Settings ................... 4-18 Step 6: Install Software NEC Express5800/ft Series offers ......... 4-19 Step 7: Set Dual LAN Configuration ................4-23 Step 8: Set Dual Disk Configuration ................4-26 Step 9: Connect and Configure Options ..............4-36 Step 10: Create Volume....................
Chapter 1 Before Using This chapter includes information necessary for proper and safe operation of the server, the main unit and its accessories. Go through this chapter before you start setup of the product.
Page 18
1-2 Before Using 在使用前 為了把本裝置做為安全確實變成使用必要的關於信息,實體及附屬品等記載著。在安裝實體之前,必定 請讀。同時,關於本文中的名稱請參照用戶指南的「與各部分的名稱功能」的項...
Before Using 1-3 NOTES FOR SAFE HANDLING The following section describes necessary information to use the product properly and safely. Warning Label Warning label is placed in the certain part of the system so that the user stays alert to possible risks. Do not remove or damage the label.
Page 20
1-4 Before Using 為了把有為了安全對待的注 意的本裝置做為安全確實變成使用必要的信息被記載。 關於警告標籤 隱藏實體內的危險性的零部件和那個週邊警告標籤被粘貼。這個是為了請操縱本裝置的時候, 經常在顧客裡(上)認識能考慮的危險性的東西(揭下標籤,請別弄髒)。如果這個標籤沒被粘貼, 剝落懸掛著,髒等做不能辨認的時候購買的銷售店請聯絡。 對以下表現被本產品粘貼的標籤的位置。 設備前部...
This equipment is not intended for use in controlling or use with facilities or systems where human lives are involved or high reliability is required, including medical devices or nuclear, aerospace, transportation, and traffic control facilities. NEC assumes no liability for any accidents or damage to physical assets resulting from the use of this equipment in such systems or facilities.
1-6 Before Using Use of Power Supply and Power Cord WARNING Do not handle power plugs with a wet hand. Do not plug/unplug power cords with a wet hand. There is a risk of an electric shock. Do not connect the ground wire to a gas pipe. Never connect the ground wire to a gas pipe.
Page 23
: sulfur dioxide, hydrogen sulfide, nitrogen dioxide, chlorine, ammonia and/or ozone. Avoid installing NEC Express5800/ft series in a dusty environment or one that may be exposed to corrosive materials such as sodium chloride and/or sulfur.
1-8 Before Using Cleaning and Handling of Internal Devices WARNING Do not disassemble, repair, or alter the server. Unless described herein, never attempt to disassemble, repair, or alter the server. There is a risk of an electric shock or fire as well as malfunction. Do not look into the DVD-ROM drive.
Before Using 1-9 CAUTION Protect the unused connectors with the protective cap. The unused power cord connectors are covered with the protective cap to prevent short circuits and electrical hazards. When removing the power cord connector from the internal devices, attach the protective cap to the connector. Failure to follow this warning may cause a fire or an electric shock.
Page 26
1-10 Before Using Rack-mount Model WARNING Do not install the server on a nonconforming rack. Install the server on a 19-inch rack conforming to the EIA standard. Do not use the server without a rack or install it on a nonconforming rack. The server may not function properly, and there is a risk of damage to physical assets or injuries.
Page 27
Before Using 1-11 CAUTION Do not install excessive wiring. To prevent burns, fires, and damage to the server, make sure that the rated load of the power branch circuit is not exceeded. For more information on installation and wiring of power-related facilities, contact your electrician or local power company. Do not pull out a device during operation.
Keep the accessories in a safe place. You will need them when you perform setup, addition of options, or replacement of failed components. To check NEC EXPRESSBUILDER components, see the attached list. Be sure to fill out and mail the software registration card that is shipped with the operating system.
2-2 About Operating System Red Hat Enterprise Linux Advanced Platform 5.2 For installing an operating system on NEC Express5800/ft series, follow “Chapter 4: Linux Setup” for setup. About supported OS The supported OS is Red Hat Enterprise Linux Advanced Platform 5.2. It is referred to as “Linux”.
Chapter 3 Installing Server This chapter describes requirements for using the product properly and safely, the setup procedures to make NEC Express5800/ft series ready for use, and how to connect peripherals.
INSTALLATION This section describes installation of NEC Express5800/ft series. Rack-mount Model You can mount NEC Express5800/ft series on a rack that conforms to the EIA standards. IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it.
Page 43
Do not leave more than one device pulled out from the rack. Do not install excessive wiring. Do not install NEC Express5800/ft series in such places as listed below. If you locate racks or install the server in such places, the server may malfunction.
Page 44
3-4 Installing Server Place that is close to some equipment that causes power noises (e.g., sparks caused by power-on/off using a relay). If you must install the server close to such equipment, request your sales agent for separate power cabling or noise filter installation.
Page 45
When the operating temperatures of NEC Express5800/ft series (10 to 35°C) are exceeded, there is a risk of malfunction. You must take adequate precautions and measures for airflow inside the rack as well as in the room so that the internal temperature can be kept within this range during operation.
Page 46
3-6 Installing Server Checking the place to install ● Imprinted mark (2 Decide the place (height) to install. To keep imprinted marks for balance, install it as low as you can on the rack. 5Us) 4U (the height To install the rack, the height for 4U is required. for installing this device) Places to install...
Page 47
Installing Server 3-7 TIPS: Core nuts (8 pieces) are not included. Use the core nuts that are attached to the rack. If the rack has front and rear doors, read the instruction that comes with the rack, and open them. Install the brackets from the rear side of the rack.
Page 48
3-8 Installing Server Fix the core nuts to the front side of the rack. Attach them symmetrically (total: 8 core nuts). Core nuts (top of device) Bottom of device Core nuts Fix a core nut from inside of the rack. Hook either of the clips of the core nut to a square hole of the rack, and hook the other clip to a hole by a flat-blade screwdriver.
Page 49
Installing Server 3-9 Tentatively fasten the washers and plate Washers and plate screws (short) screws (short) to the 4 places on the front and back sides (total: 8) from the rear. Washers and plate screws (short) Fasten tightly the washers and round screws (long) to the 2 places on the left and right sides (total: 4) from the front.
Page 50
3-10 Installing Server Fasten tightly the 4 round screws on the back side and the 8 plate screws on the side panels (which you fastened tentatively). Panhead screws on the side panels Plate screws on the side panels Plate screws on the side panels Mount the CPU/IO module 0.
Page 51
Installing Server 3-11 Return the locks on the left and right. 10. Fasten the levers on the left and right sides with screws. 11. Mount the CPU/IO module 1 in the same way.
Page 52
3-12 Installing Server Unmounting the device from the rack (N8140-74/92/93/94/98/99) Follow the steps below and unmount the device from the rack. CAUTION Observe the following precautions to use the server safely. There is a risk of a burn, personal injury, or damage to physical assets. For details, see “Notes for Safe Handling“...
Installing Server 3-13 Installing the Tower Conversion Kit (N8843-002) This section describes how to install the rack-mount model of NEC Express5800/ft series without using the dedicated rack. IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it.
Page 54
3-14 Installing Server Do not install NEC Express5800/ft series in such places as listed below. Otherwise, the server may malfunction. Place where temperatures change widely (near a heater, air conditioner, or refrigerator). Place that is subject to intense vibration. Place where corrosive gas (sodium chloride, sulfur dioxide, hydrogen sulfide, nitrogen dioxide, or ozone) is generated, or a place that is close to chemicals or exposed to chemicals.
Page 55
Installing Server 3-15 Steps to Install the Rack-mount Model to the Tower Conversion Kit Follow the procedure below to install the devices to the tower conversion kit. Open the front door of the tower conversion kit. If the door is locked, use the server-accessory key to unlock.
Page 56
3-16 Installing Server Fix the bracket with four washers and countersunk screws (long ones), two at the top and two at the bottom. Fix the bracket with 4 washers and countersunk screws. See the figure on the right for where to fix the screws (2 screws for the backside on the top, and 2 for the bottom of the tower conversion kit).
Page 57
Installing Server 3-17 Lock lever If it becomes rocked and cannot insert any further, push and keep the rock lever to the left as push the device further inside. Close the lever on the top and the bottom of the device. Fix the device to the bracket with clinchers.
To connect a third-party peripheral device or interface cable to the server, check with your sales agent to see if they are compatible with NEC Express5800/ft series. Some third-party devices may not be used with the server.
Page 59
Installing Server 3-19 IMPORTANT: Connection of optional devices In the case of standard configuration, you need to complete setup of the operating system before mounting optional PCI cards or hard disks that you purchased separately. If N8803-035 is mounted, be sure to connect cables to the FC array unit before going on to the next step.
Page 60
3-20 Installing Server Rotate the stopper clockwise, and insert the power cords to the AC inlets of the power unit. Connect the plug at the other end of the power cord to a wall outlet with parallel double-pole grounds provided or to an uninterruptible power supply (UPS).
Chapter 4 Linux Setup This chapter describes procedures for configuring OS Boot Monitoring function, setting dual LAN configuration, setting dual disk configuration and so on.
Read this section before starting setup. Use Red Hat Enterprise Linux Advanced Platform 5.2 and Red Hat Enterprise Linux Advanced Platform 5.2 Supplementary for OS installation and the NEC EXPRESSBUILDER DVD for installation of the software provided by this device.
Step 3: Disable OS Boot Monitoring Function Step 4: Install Red Hat Enterprise Linux Advanced Platform 5.2 Step 5: Post OS Install Settings Step 6: Install Software NEC Express5800/ft Series offers Step 7: Set Dual LAN Configuration Step 8: Set Dual Disk Configuration...
The following explains the setup procedure using the Express Setup program: IMPORTANT: NEC Express5800/ft series is a delicate equipment. It is recommended to ask engineer from maintenance service provider with good knowledge for setup. You need the following to install Operating System: Red Hat Enterprise Linux Advanced Platform 5.2 install CD-ROM (Disk 1 of 6)
Before install LINUX server, be sure to do the following. If these preparations are not done, setup cannot be performed properly. Prepare NEC Express5800/ft series With the power of NEC Express5800/ft series off, follow the steps below: Prepare NEC Express5800/ft series. Follow the instructions below to prepare.
Page 66
Execute the operation to be taken when AC power supply is turned off. When the AC power is off (The power cord is not plugged into the outlet) Connect the power cords to NEC Express5800/ft series in the following order: Connect the power cord to the AC inlet A connector.
For details of operations for BIOS Setup Utility and parameters, see the separate volume of User’s Guide. <Procedure for Changing BIOS settings> Turn on the display and the peripheral equipment connected to the NEC Express5800/ft series. CHECK: If the power cords are connected to a power controller like a UPS, make sure that it is powered on.
Page 68
After a while, the “NEC” logo will appear on the screen. While the “NEC” logo is displayed on the screen, NEC Express5800/ft series is performing a power-on self test (POST) to check itself. For details, see the separate volume of User’s Guide.
Page 69
Linux Setup 4-9 When the message “Press <F2> to enter SETUP” or “Press <F2> to enter SETUP or Press <F12> to boot from Network” is displayed on the display screen, press F2. The BIOS Setup Utility “SETUP” starts and the Main menu is displayed on the screen. <Example>...
Page 70
4-10 Linux Setup Move the cursor onto "Server" and select “Server.” The Server menu will be displayed. ftServer Setup Main Advanced Security Server Boot Exit Item Specific Help System Management Console Redirection Additional setup Event Log Configuration menu to view Monitoring Configuration server management features.
Page 71
Linux Setup 4-11 Move the cursor onto “OS Boot Monitoring” and press Enter. Parameters will be displayed. Among the parameters, choose “Disabled” and press Enter. The current display of the configuration for OS Boot Monitoring will be changed to “Disabled.” ftServer Setup Main Advanced...
Page 72
4-12 Linux Setup Press the Esc key to go back to the Server menu, and then move the cursor and select "Exit" to display the Exit menu. ftServer Setup Main Advanced Security Server Boot Exit Item Specific Help Exit Saving Changes Exit Discarding Changes Exit System Setup and Load Setup Defaults...
Step 4: Install Red Hat Enterprise Linux Advanced Platform In NEC Express5800/ft series, all the internal disks configure RAID1 by software. RAID consists of pairs of hard disk drives, which are CPU/IO module 0 – Slot 1 and CPU/IO module 1 – Slot 1, Slot CPU/IO module 0 –...
Page 74
4-14 Linux Setup After this, consult the Red Hat Enterprise Linux Advanced Platform 5.2 manual to install Red Hat Enterprise Linux Advanced Platform 5.2 in reference to the following partition configurations and packages. CHECK: Device names change depending on the number of hard disk drives to be mounted. Check the device name of each hard disk drive.
Page 75
/boot partition (larger than 100MB) to use the system continuously. *2 Save 2GB larger memory than the one implemented on NEC Express5800/ft Series. If the mounted memory is large enough, the swap may not be used. Save an appropriate size depending on the purpose and the load of the...
Page 76
4-16 Linux Setup system. You can check the swap usage by free command while running the system. You need to consider expanding the swap partition or adding memory when the swap usage remains high all the time. The disk pair of software RAID must be configured in combination of corresponding slot numbers.
Page 77
If the above packages are not installed, the installation described in “Step 6: Install Software NEC Express5800/ft Series offers” will fail. Therefore, ensure to install them all. IMPORTANT Ensure to leave the parameter “rhgb” untouched on the kernel parameter when you reboot for the first time after the install.
Enter the command described below and mount the DVD. #mount/dev/hda/mnt Apply the initial setup script with the below script. #/mnt/001/lnx/fysys/nec_setup.sh Enter the below command and unload the NEC EXPRESSBUILDER DVD from the optical disk drive. #eject Restart the system with the below command.
# rpm -ivh kernel-devel-2.6.18-92.1.10.el5.x86_64.rpm 4. Reboot the system. # reboot After you apply the kernel package, install the software enclosed with NEC Express5800/ft Series. ft Server Control Software IMPORTANT: The installation of ft Server Control Software must be executed by root user.
Page 80
(If they are in the middle of resync process, wait until the process completes before you move on to the next step.) # cat /proc/mdstat Set the NEC EXPRESSBUILDER DVD on the optical disk dive. Enter the command described below and mount the DVD. The mount point is described as /mnt here.
/lnx/pp/esmpro_sa. Run the install script under the above directory. # sh esminst.sh Take the NEC EXPRESSBUILDER DVD out of the optical disk drive and restart the system. TIPS: To send alert from NEC ESMPRO Agent to NEC ESMPRO Manager, the alert settings need to be specified with “Alert Setting Functions”...
Page 82
4-22 Linux Setup Processes made on esminst.sh esminst.sh executes and processes the below. snmpd environment setting portmap boot setting # /sbin/chkconfig --level 345 portmap on Install NEC ESMPRO Agent.
Linux Setup 4-23 Step 7: Set Dual LAN Configuration NEC Express5800/ft series uses Bonding for duplex of 1000 BASE LAN cards controlled by the e1000 driver and builds them as bond*(*=0,1,2…) device. Overview For duplicating a LAN, active backup for bonding is used. Active backup is a coupled-interface using multiple LAN controllers.
4-24 Linux Setup Dual Configuration Setup The following describes the procedure to set dual LAN configuration. The following example is used. Since built-in network interfaces are combined and dual network is achieved with eth100200 and eth 110200 combined as bond0, and eth100201 and eth110201 as bond1 at this point, perform only network configuration (step 2 and after).
Page 86
4-26 Linux Setup Execute the command below to activate the combined interface that has been constructed. # vndctl up 3 Execute the command below to check the status of the combined interface that has been constructed. # vndctl status --Virtual Network Status-- BondingDevice Slot Status InetAddress RXErrors TXErrors Collisions bond0 ONLINE -...
Execute Disk settings and configure dual disk when a new hard disk drive is added. Disk Configuration RAID must be configured for all the internal disks in NEC Express5800/ft series. For NEC Express5800/ft series, RAID 1 is configured by software.
Page 88
See “Verifying duplication” on page “4-30”. Use only the hard disk drives specified by NEC. If you install a third party product, not only the hard disk drive, but also the entire device may fail. Purchase a pair of two hard disks of the same model.
Page 89
Linux Setup 4-29 sdd(sdj) [3] AAA/BBB/#DDD h6c0t128l0 <Explanation of items> Slot slot number of built-in disk Name device name (kernel device name) “-“ is displayed for built-in disk that is not recognized by kernel. current mount count Information vendor name/model/serial number path SCSI path (described as h<HOST number>c<CHANNEL number>t<TARGET number>l<LUN>)
Page 90
4-30 Linux Setup Enter the number of partitions to be created. Then enter the size for each partition by MB. The remainder is automatically allocated to the partition with the last number. As for partition number, after 3 comes 5, followed in ascending order.
Page 91
This works "Every Sunday, 4:22 AM" as default just after purchasing NEC Express5800/ft or reinstalling OS. Execute ftdiskadm to change the default setting. The following describes how to change the setting.
Page 92
4-32 Linux Setup Execute “Configurations” in ftdiskadm and select “DISK_SCRUBBING_INTERVAL” from the setting menu. # ftdiskadm Command action 1 List RAID Arrays 2 List Internal Disks 3 Make Mirroring Arrays (RAID1) 4 Repair Mirroring Arrays (RAID1) 5 Delete Mirroring Arrays (RAID1) 6 Remove Disk Partitions (RAID1) 7 Make Striping Array (RAID1+0)
Page 93
Linux Setup 4-33 Fast Resync Function This function shortens the recovery time of partitions in the internal hard disk drives when the partitions are isolated from redundant configuration. (This is not the case when you replace the disks to the new ones.) Upon recovery, only refreshed data from the available hard disk drive is copied to the disk that is isolated from the redundant configuration.
Page 94
4-34 Linux Setup Creating Striping Array Striping array (RAID 0) is a RAID device that distributes I/O requests issued to striping array to each member. This function improves the I/O capacity and data writing/reading speed on striping array. Available disk capacity on striping array is the total of all members, which is different from redundant configuration RAID device (RAID 1 device).
Page 96
4-36 Linux Setup After the procedure 2., the screen shows the message that the process is going on. If the screen does not show any error and goes back to the main menu of ftdiskadm, that shows striping array is properly created. Confirm the striping array created with ftdiskadm. # ftdiskadm Command action 1 List RAID Arrays...
Step 9: Connect and Configure Options If there is any optional PCI board or peripheral equipment to connect to NEC Express5800/ft series, turn off the power of NEC Express5800/ft series, and connect it according to the “PCI board” in User’s Guide and the device’s instruction.
4-38 Linux Setup Step 10: Create Volume If there is free disk space in the internal disk with the OS, you can create a volume. To create a volume in the free disk space and construct RAID partition,, follow the steps below. IMPORTANT: Ask maintenance service provider having expertise to perform the following operation.
Page 99
Linux Setup 4-39 “t”.>>> Command (m for help): n First cylinder (8382-8899, default 8382): Using default value 8382 Last cylinder or +size or +sizeM or +sizeK (8382-8899, default 8899): +1024M Command (m for help): t Partition number (1-6): 6 Hex code (type L to list codes): fd Changed system type of partition 6 to fd (Linux raid autodetect) Command (m for help): w <<<...
Page 100
4-40 Linux Setup It shows that the new RAID device md4 successfully constitutes the added partitions /dev/sda6 and /dev/sdd6. To create more, repeat the same procedures.
OS by using Linux for NEC Express5800/ft series Back UP DVD-ROM. To run NEC ESMPRO Agent, you need to make settings of the SNMP. For details and methods of the settings, see from “2. Environment settings of snmpd” to “5. Setting SELinux” on “NEC...
4-42 Linux Setup Step 12: Enable OS Boot Monitoring Function When necessary for system operation, enable the “OS Boot Monitoring” setting which has been disabled in “Step 3: Disable OS Boot Monitoring Function” (page 4-7) and set appropriate time (default is 10 min.). ftServer Setup Main Advanced...
Take the following steps to make a backup copy of the system information: Prepare a 3.5-inch floppy disk. Insert the "NEC EXPRESSBUILDER" DVD-ROM into the optical disk drive of the server, and restart the system. NEC EXPRESSBUILDER is activated and [NEC EXPRESSBUILDER Top Menu] is displayed.
Chapter 5 Procedures after Completion of Installation This chapter describes how you install management utilities, how you back up system information, and setup of PCs on the network. You may need to confirm these procedures while the system is running.
The provided "NEC EXPRESSBUILDER" DVD contains "NEC ESMPRO Agent" for monitoring NEC Express5800/ft series and "NEC ESMPRO Manager" for managing the NEC Express5800/ft series. Install and setup these utilities in the NEC Express5800/ft series or the computer (management PC) that manages the NEC Express5800/ft series.
NEC ESMPRO Agent is a utility to monitor the operating status, the configuration information, the failure occurrence status of hardware and software on the NEC Express5800/ft series. When it detects some problems, it sends messages to the computer in which the NEC ESMPRO Manager is installed.
Page 108
IMPORTANT: Be sure to read the following before system installation or setup. To operate NEC ESMPRO Agent, each service must be installed appropriately and must be running. 1. Check necessary packages The following packages are needed to use NEC ESMPRO Agent.
Page 109
The environment setting file for snmpd on NEC Express5800/ft series is /etc/opt/ft/snmp/snmpd.conf. When rebooting snmpd, the appropriate environment setting file may not be applied and NEC ESMPRO Agent cannot be operated properly. For the proper operation, ft-snmp needs to be rebooted.
Page 110
Configure this setting by running esminst.sh. Set portmap to start automatically. # /sbin/chkconfig --level 345 portmap on 4. Setting firewall When monitoring from the NEC ESMPRO Manager, use the following port. If you set the firewall on your environment, set the access permission to the following port. snmp 161/udp snmp-trap 162/udp 5.
Page 111
Procedures after Completion of Installation 5-7 SELinux status: enabled <-Please check here.:...
Page 112
1. Log in to the system as a root user. 2. Set the NEC EXPRESSBUILDER to the optical disk drive. 3. Move to the directory where the package of the NEC ESMPRO Agent is stored. # cd /(mount point)/001/lnx/pp/esmpro_sa/ ESMPRO Agent exists under the “001/lnx/pp/esmpro_sa/”.
Page 113
Procedures after Completion of Installation 5-9 Uninstallation procedure 1. Log in to the system as a root user. 2. Run the following command to uninstall the package: # rpm -e Esmpro-Express # rpm -e Esmpro-ft # rpm -e Esmpro-type1 # rpm -e Esmpro-common 3.
Page 114
Follow the instructions below to setup the NEC ESMPRO Agent. 1. Log in the system as a root user. 2. Move to the directory where the NEC ESMPRO Agent is installed. # cd /opt/nec/esmpro_sa 3. Move to the directory where the control panel is stored.
Procedures after Completion of Installation 5-11 Report Setting To report from the NEC ESMPRO Agent to the NEC ESMPRO Manager, you need to set the method of report. Setting of Manager (SNMP) 1. Log in the system as a root user.
Page 116
Set enable/disable using space key. When checked, it is enabled. When not checked, it is disabled. 8. Select [Add] to set [Trap Destination IP]. Set the IP address of the device where the NEC ESMPRO Manager is installed. 9. Finish the tool. The report will be performed to the NEC ESMPRO Manager.
Notify Monitor When a failing module in the server is to be replaced, NEC ESMPRO Manager enables logical module disconnection from the server and logical installation after module replacement. For the installation of NEC ESMPRO Manager and notes on the operation, see the separate volume...
This process is performed when the version of the kernel in operation needs to be checked, such as when a device is added to NEC Express5800/ft series. Confirm the version following the steps below. Execute the command below.
The following describes how to check the version of ft Server Control Software, which consists of various types of software for fault tolerance. Perform the procedure when you need to check the ft Server Control Software version of the current system before adding units or attachment to NEC Express5800/ft series.
Page 120
5-16 Procedures after Completion of Installation (This page is intentionally left blank.)
Chapter 6 SYSTEM REPAIR For RAID repair procedures upon disk failure, see the User’s Guide “Disk Operation” in the Linux Setup and Operation “Chapter 3 ” (P.3-2). IMPORTANT: If the hard disk drive cannot be recognized, the system cannot be repaired. To execute this configuration, login as a user with root privilege.
Did you set the NEC EXPRESSBUILDER DVD during POST and restart the server? → If you do not set the NEC EXPRESSBUILDER DVD during POST and restart the server, an error message will appear or the OS will boot.
Appendix A About Services Information on NEC Express5800/ft series is provided the web at NEC Express5800 Web ASIA PACIFIC http://www.nec.co.jp/express/...
Page 126
N8800-124F, EXP320J NEC Express5800/320Fd-LR N8800-125F, EXP320K NEC Express5800/320Fd-MR User's Guide (Setup) 2nd Edition 10-2008 856-127506-122-B...