free stats
NEC Univerge SV8100 System Maintenance Manual

NEC Univerge SV8100 System Maintenance Manual

Hide thumbs Also See for Univerge SV8100:

Advertisement

Notice
Note that when converting this document from its original format to a
.pdf file, some minor font and format changes may occur. When
viewing and printing this document, we cannot guarantee that your
specific PC or printer will support all of the fonts or graphics.
Therefore, when you view the document, fonts may be substituted and
your individual printer may not have the capability to print the
document correctly.

Advertisement

Table of Contents
loading

Summary of Contents for NEC Univerge SV8100

  • Page 1 Notice Note that when converting this document from its original format to a .pdf file, some minor font and format changes may occur. When viewing and printing this document, we cannot guarantee that your specific PC or printer will support all of the fonts or graphics. Therefore, when you view the document, fonts may be substituted and your individual printer may not have the capability to print the document correctly.
  • Page 3: Issue 1.0

    System Maintenance Manual INT-2057 (UNIV) ISSUE 1.0...
  • Page 5 NEC Unified Solutions, Inc. reserves the right to change the specifications, functions, or features at any time without notice. NEC Unified Solutions, Inc. has prepared this document for use by its employees and customers. The information contained herein is the property of NEC Unified Solutions, Inc. and shall not be reproduced without prior written approval of NEC Unified Solutions, Inc.
  • Page 7 Preface Before Reading this Manual This manual provides detailed information for diagnostic and maintenance information for the SV8100 system. There are three parts to this manual: Chapter 1 – Troubleshooting IP on an SV8100 System This chapter provides some helpful tips for troubleshooting IP on the SV8100 system. Chapter 2 –...
  • Page 8 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 9: Table Of Contents

    Troubleshooting IP on an SV8100 System Section 1 Introduction ....................1-1 Section 2 Ping ......................1-1 Pinging from a PC ..................1-3 Pinging from an UNIVERGE SV8100 IP Phone ........1-3 Section 3 Packet Traces .................... 1-5 Chapter 2 System Maintenance Section 1 Introduction ....................
  • Page 10: Chapter 3 Diagnostics

    Issue 1.0 UNIVERGE SV8100 ___________________________________________________________________________________ Chapter 3 Diagnostics Section 1 What is Available? ..................3-1 Section 2 Before you Start ..................3-1 Section 3 To Log On to the DIM Locally via the Ethernet Socket of the CD-CP00-US ..................... 3-2...
  • Page 11 LIST OF FIGURES ___________________________________________________________________________________ Figure 1-1 Ping Traces ........................ 1-2 Figure 1-2 Ping Usage Example ....................1-4 Figure 1-3 Trace File Example ....................1-6 Figure 3-1 SV8100 Ethernet Properties ..................3-2 Figure 3-2 SV8100 System Activity ..................... 3-3 ___________________________________________________________________________________ System Maintenance Manual...
  • Page 12 Issue 1.0 UNIVERGE SV8100 ___________________________________________________________________________________ THIS PAGE INTENTIONALLY LEFT BLANK ___________________________________________________________________________________ List of Figures...
  • Page 13: Introduction

    PING is a standard component of Microsoft Windows and is also implemented on the UNIVERGE SV8100 IP Phones. Ping sends a small IP packet to a specified destination and waits for a response back. It should be possible to ping IP Phones, the CD-CP00-US (CPU), PZ-32IPLA (32 VoIP), PZ-64IPLA (64 VoIP), PZ-128IPLA (128 VoIP) and any other devices on the network.
  • Page 14: Figure 1-1 Ping Traces

    Issue 1.0 UNIVERGE SV8100 Successful Ping Trace Unsuccessful Ping Trace Figure 1-1 Ping Traces 1 - 2 Troubleshooting IP on an SV8100 System...
  • Page 15: Pinging From A Pc

    Sends ten 40-byte packets to 192.168.2.100 ping 192.168.2.100 Sends four 32-byte packets (default) to 192.168.2.100 Pinging from an UNIVERGE SV8100 IP Phone The System IP Phone has a version of ping within the Maintenance Menu. Hold down help button for 3 sec Press 3 (Ping)
  • Page 16: Figure 1-2 Ping Usage Example

    Issue 1.0 UNIVERGE SV8100 An example of ping usage: A UNIVERGE SV8100 IP Phone unsuccessfully attempts to connect to the UNIVERGE SV8100 system as shown in Figure 1-2 Ping Usage Example. UNIVERGE SV8100 192.168.2.100 Leased Line Default Gateway IP Phone Default Gateway 192.168.1.1...
  • Page 17: Packet Traces

    UNIVERGE SV8100 Issue 1.0 Examples: The UNIVERGE SV8100 IP Phone can successfully ping all devices up to and including the local router. Anything beyond that point fails. This would suggest that the Leased Line or remote router has a problem.
  • Page 18 Issue 1.0 UNIVERGE SV8100 Figure 1-3 Trace File Example 1 - 6 Troubleshooting IP on an SV8100 System...
  • Page 19: Chapter 2 System Maintenance

    ROCEDURES ECTION General Information When an UNIVERGE SV8100 system is first powered up, an initialization is performed. During this process the CD-CP00-US (CPU), located in the first chassis, scans each interface slot to determine the hardware configuration used. This information is stored in the resident system program memory with the system default values.
  • Page 20: Initialization Check

    Second Initialization refreshes the system RAM without losing any memory. This completes the installation procedure for the UNIVERGE SV8100 system. The technician should check the operation of each Multiline Terminal to ensure the system is working properly.
  • Page 21: Troubleshooting

    Issue 1.0 ROUBLESHOOTING ECTION Remote Administration and Maintenance PCPro can remotely access the UNIVERGE SV8100 system for maintenance and diagnostics. The remote PC and the system are connected using a modem on the CD-CP00-US or using IP. Problem Solving To find the cause, consider all problem symptoms carefully. As each aspect of the problem is considered, the technician is guided to a probable solution.
  • Page 22: Flowcharts

    Issue 1.0 UNIVERGE SV8100 Flowcharts Condition Flowchart Page A. System Down 1. No Internal Dial Tone to any Multiline Terminal or SLT 2. No LED or Display Indications on any Multiline Terminal Partial Operations 1. Frequency Interference 2. No or Intermittent CO/PBX Ring 3.
  • Page 23: Issue 1.0

    UNIVERGE SV8100 Issue 1.0 No internal Dial Tone to any Multiline Terminal or SLT Are LEDs on front of chassis panel lit on Check AC Input CD-CP00-US or any Power. other blade? Turn system Off. Disconnect all connectors and remove all blades except CD-CP00-US...
  • Page 24: System Maintenance

    Issue 1.0 UNIVERGE SV8100 No LED or Display Indications on any Multiline Terminal Are LEDs on front of Check AC Input chassis panel lit on Power. CD-CP00-US or any other blade? Terminate one Multiline Terminal to controlling chassis, 1st CD-8DLCA...
  • Page 25 UNIVERGE SV8100 Issue 1.0 Frequency Interference (RFI) Is interference only on outside calls or anytime station is off-hook? Remove one CO line Outside calls at MDF and test using RFI Event? standard SLT. Any off-hook RFI on CO Check cable for the Lines? affected terminal(s).
  • Page 26 Issue 1.0 UNIVERGE SV8100 No or Intermittent CO/PBX Ring Test to see if problem occurs on one line or several lines. Several Lines One Line See if problem occurs on Check PRG 22-04 to ensure that line is all Multiline Terminals...
  • Page 27 UNIVERGE SV8100 Issue 1.0 Call Dropping See if problem exists on all Lines. Calls dropped on all lines? lines at same time? Check DC voltages with Check outside line key a meter and AC power after call drops. with a line disturbance analyzer.
  • Page 28: Ring

    Issue 1.0 UNIVERGE SV8100 No Outside Dial Tone Access Multiline Terminal Multiline Check for Internal Terminal or SLT? Dial tone. Both Terminals Internal affected? Dial Tone? Check for Internal Dial tone. 1. Perform Second 1. Reset terminal Initialization. and test.
  • Page 29: Co/Pbx Dialing Problem: Cannot Dial Out On Co

    UNIVERGE SV8100 Issue 1.0 CO/PBX Dialing Problem: Cannot Dial Out on CO Check CO lines at MDF Check problem with test set to see if they PRG 15-03-01. only? are DTMF or DP. DTMF DTMF Line type DP or program?
  • Page 30: Multiline Terminal Function D1

    Issue 1.0 UNIVERGE SV8100 Multiline Terminal Function Problems Go to Flowchart A2. terminals? Check PRG 10-03-01for correct Station Assignment. Assignment Reassign. correct? Problem End. Perform Multiline Terminal Self Test: solved? 1. Unplug terminal line cord. 2. Hold down and # together and plug in the line cord.
  • Page 31: Multiline Terminal Ringing D2

    UNIVERGE SV8100 Issue 1.0 Multiline Terminal Ringing Problems Intermittent Problem? Go to Flowchart C1. Consistent Check to see if problem occurs on CO or internal calls (including station-to-station or transferred calls). Internal Check to see if station is Problem? Check PRG 15-07.
  • Page 32: Multiline Terminal Dial Tone Access D3

    Issue 1.0 UNIVERGE SV8100 Multiline Terminal Dial Tone Access Problems Check to see if problem occurs on CO or Internal call. Internal CO or Internal dial Go to Flowchart A1. Go to Flowchart C3. tone? Both Go to Flowchart A1.
  • Page 33 UNIVERGE SV8100 Issue 1.0 No Dial Tone Access on SLT Check PRG 10-03 for CD-4LCA/CD-8LCA assignments. Problem Assignment Assign Again. End. solved? correct? Both No CO Check CO line dial tone on or internal Replace SLT, and test. a Multiline Terminal.
  • Page 34 Issue 1.0 UNIVERGE SV8100 Ringing Problem on SLT Replace SLT. Problem SLT defective. solved? Check to see if ringing problem is intermittent. Check to see if SLT is Intermittent call forwarded. Problem? Cancel call Call Forwarding. Forward? Check CD-4LCA /CD-8LCA for ring voltage output with AC meter.
  • Page 35 UNIVERGE SV8100 Issue 1.0 No Dial Access to Features on SLT Check to see if SLT can access internal or CO dial tone. Access dial Go to Flowchart E1. tone? Check PRG 20-06 for feature assignment. Good Feature Program COS to allow Done.
  • Page 36 Issue 1.0 UNIVERGE SV8100 Low Volume Problems All lines? Bridge on All stations? Remove it. system CO line? Replace Run a dB level test at DMARK Multiline SLT. on lines with 1 kHz test tone. No less than -8dB at MDF is Move suspected bad line to required.
  • Page 37 UNIVERGE SV8100 Issue 1.0 External Paging Problems Amplifier Install amplifier. provided? Place Test Set on output of paging at chassis port or PGD(2)-U10 ADP with all external wiring removed. External page heard on test set? External amplifier or PRG Check PRG 11-01 and PRG 11-10 ~...
  • Page 38 Issue 1.0 UNIVERGE SV8100 SMDR Output Problems (No Call Accounting System) Incoming problem only? Check PRG 35-02-08. Output Method? TCP/IP Is Output Type Set correctly? Check PRG 35-01-01. Set PRG 35-01-01 Correctly. to A 2 - 20 System Maintenance...
  • Page 39 UNIVERGE SV8100 Issue 1.0 Is the call Does the Is SMDR Is language type trunk port Correct? included in provide Correct? SMDR? SMDR? Set Trunk to provide. Include the call type. Correct the language. Set port correctly for Check PRG 14-01-06.
  • Page 40 Issue 1.0 UNIVERGE SV8100 - - NOTES - - 2 - 22 System Maintenance...
  • Page 41: What Is Available

    Diagnostics HAT IS VAILABLE ECTION The SV8100 has a Diagnostic Interface Module (DIM) built into the CD-CP00-US (CPU) blade. The DIM can monitor the activity of the system under the control of commands entered by the engineer. The DIM is Chapter accessed via ia the Ethernet interface of the CD-CP00-US blade.
  • Page 42: Cd-Cp00-Us

    Issue 1.0 UNIVERGE SV8100 The SV8100 CD-CP00-US can slow down when the DIM is running on a busy SV8100 system. This is unavoidable, as the CD-CP00-US must process all system activity and output the corresponding information to the DIM. DIM L...
  • Page 43: Cd-Cp00-Us

    UNIVERGE SV8100 Issue 1.0 When the connection is made the following information is required: User ID: monimoni Password: hihi Connection to the DIM is made and system activity is observed. Refer to Figure 3-2 SV8100 System Activity. Figure 3-2 SV8100 System Activity...
  • Page 44 Issue 1.0 UNIVERGE SV8100 SV8100 DIM C OMMANDS ECTION Once connected to the DIM, commands are entered by typing the command (with correct syntax), and pressing Enter. To display the list of DIM commands available on the SV8100 type: help...
  • Page 45 UNIVERGE SV8100 Issue 1.0 Typed Command Displayed Result TYPE FILE DISP COPY FILE COPY FDUMP FILE DUMP(Binary) RENAME FILE RENAME DSP direct r/w LCD Request POWER Power Management CALLKEY am::Callkey module ESIU ESIU control SH3 control HELP This help display...
  • Page 46 Issue 1.0 UNIVERGE SV8100 Typed Command Displayed Result SHUTDOWN Shutdown EVNTCTRL Event Controller CIDTX Caller ID sender TONE LOCAL TONE IPPATH IP JITTER & SW P2PSTS p2pStatus[] Disp DTERMCTRL Dterm Control NWINFO Networking Information TRLHC Trillium HC layer debug information...
  • Page 47: Common Dim Commands

    UNIVERGE SV8100 Issue 1.0 DIM C OMMON OMMANDS ECTION Enter Function DIM Output Mail in 0000 Output of all system activity is Enter CAPS debug mode. turned on. The activity of all extensions and lines is No ISDN information output.
  • Page 48 Issue 1.0 UNIVERGE SV8100 The output is shown similar to that of an ISDN Layer 3 analyzer: SEND PORT = 4C1FH S ISDN : >>>>>>>>>>>>>>>>>>>> 11 A1 11 02 01 00 USL (3,2), SETUP ACK REQ 08 01 84 0D...
  • Page 49 UNIVERGE SV8100 Issue 1.0 SV8100 N DIM C OMMANDS ECTION Enter Function DIM Output NWINFO Lists the NWINFO DEBUG Networking Debug Information [ON|OFF] commands NWINFO RSRC Netport Reosurce Controller available NWINFO BLF Blf Memory Dump NWINFO TCPINIT Dummy CR data send Task refresh...
  • Page 50 Issue 1.0 UNIVERGE SV8100 Date Enter Function DIM Output date Displays the current date / Current date/time : 1-1-2002 (TUE) 0:17:41 time and general system System build date : Jul 16 2004 16:56:25 information including [Target is North America (Electra)] CD-CP00-US software Main software version : 00.1u...
  • Page 51 UNIVERGE SV8100 Issue 1.0 * PORT STATUS (0401 --> 000f)* PORT(PHYS) STATUS CALL HOLD 0401h(0001h) : IDLE( 0h) 0000h 0000h 0402h(0101h) : IDLE( 0h) 0000h 0000h ----h(----h) : (----h) ----h ----h no station port is assigned ----h(----h) : (----h) ----h ----h no station port is assigned...
  • Page 52 Issue 1.0 UNIVERGE SV8100 Real unit ID : 12H Version : 1.8 Firmware loaded onto the Blade Lines / unit : 8 Number of ports on the card (8ESIU) Block switch : RUN Block switch set to RUN Timeslot : 000H-00FH (16)
  • Page 53 UNIVERGE SV8100 Issue 1.0 Power Enter Function DIM Output Power List the status of the power and Power off request : none backup battery. Power source : AC(Normal) System battery : normal Backup battery : normal No power keep requests available...
  • Page 54: Ip Related Commands

    Issue 1.0 UNIVERGE SV8100 IP R ELATED OMMANDS ECTION Enter Function DIM Output IP INFO Displays a list of IP Usage> ip info [para] information [para] : 0(IP Version) : 2 (CAPS Call Info Table Dump) : 3 (IP Station Regist Table Dump)
  • Page 55 UNIVERGE SV8100 Issue 1.0 This table shows all extensions that are registered to the SV8100 – not those that are currently connected. ########## IP Phone Table ########## --DtermIP------------------------------------------- Extension Number = 3203 SerialPort = 257 IP Address 192.168.1.131 Voice Path Port=4000...
  • Page 56 Issue 1.0 UNIVERGE SV8100 ip info 8 This command shows the CD-CP00-US IP Address information entered in PRG10-12. Example: [ CCPU IP Info ] IP Addr : 192.168. 1. 20 Sub Net Mask : 255.255.255. 0 Default Gatway : 192.168. 1.254...
  • Page 57 UNIVERGE SV8100 Issue 1.0 [RegId20][UserId:] not REGISTERED to SIP Server(1/30 8:50) [RegId21][UserId:] not REGISTERED to SIP Server(1/30 8:50) [RegId22][UserId:] not REGISTERED to SIP Server(1/30 8:50) [RegId23][UserId:] not REGISTERED to SIP Server(1/30 8:50) [RegId24][UserId:] not REGISTERED to SIP Server(1/30 8:50) [RegId25][UserId:]...
  • Page 58 00:30:13:16:E8:6F 113785925 192.168.001.030 00:60:B9:C1:B2:30 113749983 192.168.001.040 00:60:B9:C1:C3:BF 113749986 192.168.102.200 00:60:B9:C2:07:4F 82736183 192.168.001.131 00:60:B9:C1:71:AA 113776316 192.168.001.121 00:30:05:44:98:5D 113778849 192.168.001.144 00:30:13:B5:D2:27 441024 192.168.001.146 00:00:86:63:25:87 113800591 192.168.001.197 00:30:13:B5:E8:79 17550119 Any NEC Infrontia device has a MAC address beginning with 00:60:b9. 3 - 18...
  • Page 59 UNIVERGE SV8100 Issue 1.0 ip route Network DestAddr Netmask Gateway Next Hop Metric 127.000.000.000 255.000.000.000 127.000.000.001 000.000.000.000 224.000.000.001 255.255.255.255 127.000.000.001 000.000.000.000 192.168.001.000 255.255.255.000 192.168.001.020 000.000.000.000 192.168.001.020 255.255.255.255 127.000.000.001 000.000.000.000 Default Route: 192.168.001.254 ip dsp info VoIPU Dsp Resource Management Table)
  • Page 60 Issue 1.0 UNIVERGE SV8100 ip dsp info 1 IP Station Physical Port Table 01-010] ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- [011-020] ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- [021-030] ---- ---- ---- ---- ---- ---- ---- ---- ---- ----...
  • Page 61 UNIVERGE SV8100 Issue 1.0 IP Trunk Physical Port Table [001-010] ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- [011-020] ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- [021-030] ---- ---- ---- ---- ---- ---- ---- ---- ---- ----...
  • Page 62 Issue 1.0 UNIVERGE SV8100 VoIPU DSP Resource Management Table #Slot:01 Busy:- ------- #Slot:02 Busy:- ------- #Slot:03 Busy:- ------- #Slot:04 Busy:- ------- #Slot:05 Busy:- ------- #Slot:06 Busy:- ------- #Slot:07 Busy:- ------- #Slot:08 Busy:- ------- #Slot:09 Busy:- ------- #Slot:10 Busy:- ------- #Slot:11 Busy:- -------...
  • Page 63: Reading Sv8100 Dim Traces

    EADING RACES ECTION The DIM trace can be partly decoded by the engineer but only NEC Infrontia Japan can decode the full trace. This section describes the basic decode to enable the engineer to identify the extension and trunk port number.
  • Page 64 Issue 1.0 UNIVERGE SV8100 SV8100Net Each trunk type has a unique logical port type as shown below. Type Logical ID ISDN The port number is identified by the two digits (in hexadecimal) following the logical port type. The two digits are 00 to ff hexadecimal (00 to 255 in decimal).
  • Page 65 UNIVERGE SV8100 Issue 1.0 ISDN L 0 0 1 2) AYER RACE AIL IN ECTION A typical ISDN Layer 3 trace is shown: 9:56:48 >> 9:56:48 >>mail in 0 0 1 2 Enter ISDN Debug Mode 9:56:53 >> Enter ISDN debug mode...
  • Page 66 Issue 1.0 UNIVERGE SV8100 R ISDN : <<<<<<<<<<<<<<<< 11 0B A1 02 01 01 00 USL(8,1),CALL PROCEEDING IND Network returns Call Proceeding. 08 02 80 03 02 Callref:DES(3),CALL PROCEEDING 18 03 A9 83 81 Channel identification PHYSICAL_W =0108HR ISDN : <<<<<<<<<<<<<<<<...
  • Page 67 UNIVERGE SV8100 Issue 1.0 ISDN L 0 0 1 2) SV8100 M AYER RACE MAIL IN WITH ECTION 0 0 0 0) CTIVITY AIL IN If the same call is traced with both ISDN debug (mail in 0 0 1 2) and SV 8100 Main Activity (mail in 0 0 0 0) switched on the trace will be as shown below.
  • Page 68 Issue 1.0 UNIVERGE SV8100 SET_CALL_REF CALLED! PHYSICAL_W =0108HSET_CALL_REF: PRI =8004H *** set_call_ref resource# : 1H *** <<< prgrd1501.cpp(38) read_s_sta_clip_enable >>> port : 0, data : 1 S ISDN : >>>>>>>>>>>>>>>> F4 A1 04 01 01 00 USL(8,1),SETUP REQ The trace will be the...
  • Page 69 UNIVERGE SV8100 Issue 1.0 R ISDN : <<<<<<<<<<<<<<<< 11 0B A1 02 01 01 00 USL(8,1),CALL PROCEEDING IND 08 02 80 04 02 Callref:DES(4),CALL PROCEEDING 18 03 A9 83 81 Channel identification PHYSICAL_W =0108H..3415(00B2-0401) 0981 >>>> PORT:3415H STATUS 00B2H => 00B3H...
  • Page 70 Issue 1.0 UNIVERGE SV8100 *(INTER),ID:0401H,P1:3415H,P2:0000H,P3:0804H,P4:0000H,P5:0000H S ISDN : >>>>>>>>>>>>>>>> F4 A1 0C 01 01 00 USL(8,1),RELEASE REQ 08 02 00 04 4D Callref:ORG(4),RELEASE 08 02 80 90 Cause (16) >>>> PORT:3415H STATUS 00BCH => 00C3H *(EVENT),ID:001FH,P1:1101H,P2:0000H,P3:0000H,P4:0000H,P5:0000H == 1/JAN/2002, 10:12 == *(EVENT),ID:0004H,P1:080BH,P2:0000H,P3:DF08100H,P4:0000H,P5:0000H R ISDN : <<<<<<<<<<<<<<<<...
  • Page 71: Section 12 Sv8100Net Trace (Nwinfo Debug Light)

    UNIVERGE SV8100 Issue 1.0 SV8100N RACE WINFO EBUG IGHT ECTION The following trace shows an SV8100Net trace of a call from extension port 01 that dials a remote extension: 200. It is useful to monitor the Network ID and IP Address used for SV8100Net calls.
  • Page 72 Issue 1.0 UNIVERGE SV8100 * NwInfo> CNETWORK_MAIN is called.[7c01] * NwInfo> cnetwork_pro07 is called * NwInfo> Process comes to exception procedure. (event:0990) cnetmain src:7c01 oldSrcPort:0401->src_port_w:0401 rsrc:1(H323) status 0024 -> 0024 * NwInfo> CNETWORK_MAIN is called.[7c01] * NwInfo> Process comes to exception procedure. (event:001c) * NwInfo>...
  • Page 73 UNIVERGE SV8100 Issue 1.0 * NwInfo> Search Free Resource... * NwInfo> Free resource searching abort...!! signal:0804 * NwInfo> cnetwork_pro00 is called Networking procedure was not executed. System Maintenance Manual 3 - 33...
  • Page 74 Issue 1.0 UNIVERGE SV8100 SV8100N ISDN D RACE SING THE EBUG RACE AIL IN ECTION 0012) 10:53:20 >>mail in 0 0 1 2 10:53:23 >> Enter ISDN debug mode master current bid : 08H master current line : 00H ACD Data Size error. or socket close...
  • Page 75 UNIVERGE SV8100 Issue 1.0 +00 03 04 02 08 00 00 04 +0C 45 58 54 20 32 30 30 +20 20 20 20 20 1A 01 00 +05 01 01 13 01 01 21 01 +00 2E 01 00 3B 04 01 04...
  • Page 76 Issue 1.0 UNIVERGE SV8100 - - NOTES - - 3 - 36...
  • Page 78 System Maintenance Manual NEC Unified Solutions, Inc. Issue 1.0...

This manual is also suitable for:

Univerge sv8100

Table of Contents