hit counter script

Upgrading A Supervisor Module - Cisco Nexus 9508 Hardware Installation Manual

Aci-mode switch
Hide thumbs Also See for Nexus 9508:
Table of Contents

Advertisement

Upgrading a Supervisor Module

1
Slide the middle handle toward the end of the ejector
lever.
2
Rotate the ejector lever away from the module.
d) Rotate the lever all the way to the front of the chassis until it locks in place with a click.
Make sure that the lever engages behind the front of the slot so that the module fully seats onto the connectors on the
midplane.
e) Screw in the two captive screws to secure the module to the chassis. Tighten the screws to 8 in-lb (0.9 N·m) of torque.
f) Attach the following cables to the module:
• Console cable—Attach to the Console port.
• Management cable—Attach to the Management Ethernet port.
g) Verify that the supervisor module LEDs turn on and appear as follows:
• The Status (STS) LED is green.
• The Active (ACT) LED is amber or green.
Upgrading a Supervisor Module
You can upgrade supervisor modules by using the hot swap method. The upgrade path for your active supervisor
module can be found in the following table:
Active Supervisor
Supervisor A
Supervisor A
Cisco Nexus 9508 ACI-Mode Switch Hardware Installation Guide
52
Replacing or Installing Modules, Fan Trays, and Power Supplies
3
Slide the back end of the module into the open
supervisor slot.
Allowed Upgrade
Supervisor A+
Supervisor B+

Advertisement

Table of Contents
loading